MARIANNY NAZARETH SULBARAN NAVA

(Fonte: Lattes)
Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais

Resultados de Busca

Agora exibindo 1 - 4 de 4
  • article 7 Citação(ões) na Scopus
    Systematic review and meta-analysis of colon capsule endoscopy accuracy for colorectal cancer screening. An alternative during the Covid-19 pandemic?
    (2022) SULBARAN, Marianny; BUSTAMANTE-LOPEZ, Leonardo; BERNARDO, Wanderley; SAKAI, Christiano M.; SAKAI, Paulo; NAHAS, Sergio; MOURA, Eduardo G. H. de
    Aim To determine the diagnostic accuracy of colon capsule endoscopy for colorectal cancer screening. Methods Studies that compared the diagnostic performance of colonoscopy and second-generation colon capsule endoscopy (CCE-2) for screening of asymptomatic patients aged 50-75 years were included. The primary outcomes were sensitivity, specificity, and positive and negative likelihood ratios for polyps and adenomas measuring at least 6 mm or 10 mm. Results Eight full-text studies that evaluated 1602 patients were included for systematic review. Of these, 840 (52.43%) patients participated in an opportunistic screening program. The pooled outcomes of CCE-2 for polyps at least 6 mm / 10 mm were (CI = confidence interval): sensitivity: 88% (95% CI: 0.84-0.91) / 88% (95% CI: 0.82-0.93), specificity: 94% (95% CI: 0.92-0.95) / 95.5% (95% CI: 0.94-0.97); positive likelihood ratio: 11.86 (95% CI: 5.53-25.46) / 23.07 (95% CI: 6.163-86.36); negative likelihood ratio: 0.14 (95% CI: 0.1-0.21) / 0.14 (95% CI: 0.09-0.21). The area under the summary receiver operating characteristic curve for polyps at least 6 and 10 mm was 96.3% and 96.7%, respectively. The only cancer missed by complete CCE-2 was shown at multiple frames in the unblinded review. In total, 125 (7.8%) patients presented mild adverse events mostly related to bowel preparation. Conclusion CCE-2 is demonstrated to be an effective and safe alternative method for colorectal cancer screening. Diagnostic performance of CCE-2 for polyps of at least 6 and 10 mm was similar. Completion rates still need to be improved.
  • article
    Overtube-assisted enteroscopy and capsule endoscopy for the diagnosis of small-bowel polyps and tumors: a systematic review and meta-analysis
    (2016) SULBARAN, Marianny; MOURA, Eduardo de; BERNARDO, Wanderley; MORAIS, Cintia; OLIVEIRA, Joel; BUSTAMANTE-LOPEZ, Leonardo; SAKAI, Paulo; MOENKEMUELLER, Klaus; SAFATLE-RIBEIRO, Adriana
    Background and study aims: Several studies have evaluated the utility of double-balloon enteroscopy (DBE) and capsule endoscopy (CE) for patients with small-bowel disease showing inconsistent results. The aim of this study was to determine the sensitivity and specificity of overtube-assisted enteroscopy (OAE) as well as the diagnostic concordance between OAE and CE for small-bowel polyps and tumors. Patients and methods: We conducted a systematic review and meta-analysis of studies in which the results of OAE were compared with the results of CE for the evaluation of small-bowel polyps and tumors. When data for surgically resected lesions were available, the histopathological results of OAE and surgical specimens were compared. The sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio for the diagnosis of small-bowel polyps and tumors were analyzed. Secondarily, the rates of diagnostic concordance and discordance between OAE and CE were calculated. Results: There were 15 full-length studies with a total of 821 patients that met the inclusion criteria. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were as follows: 0.89 (95% confidence interval [CI] 0.84-0.93), with heterogeneity chi(2)=41.23 (P = 0.0002) and inconsistency (I-2)=66.0 %; 0.97 (95 % CI 0.95-0.98), with heterogeneity chi(2)=45.27 (P=0.07) and inconsistency (I-2)=69.1 %; 16.61 (95 % CI 3.74-73.82), with heterogeneity Cochrane's Q=225.19 (P<0.01) and inconsistency (I-2)=93.8 %; and 0.14 (95 % CI 0.05-0.35), with heterogeneity Cochrane's Q=81.01 (P<.01) and inconsistency (I-2)=82.7 %, respectively. A summary receiver operating characteristic curve (SROC) curve was constructed, and the area under the curve (AUC) was 0.97. Conclusion: OAE is an accurate test for the detection of small-bowel polyps and tumors. OAE and CE have a high diagnostic concordance rate for small-bowel polyps and tumors. This study was registered in the PROSPERO international database (www.crd.york.ac.uk/prospero/) with the study number CRD42015016000.
  • article 37 Citação(ões) na Scopus
    Prevention of esophageal stricture after endoscopic submucosal dissection: a systematic review and meta-analysis
    (2016) OLIVEIRA, J. F.; MOURA, E. G. H.; BERNARDO, W. M.; IDE, E.; CHENG, S.; SULBARAN, M.; SANTOS, C. M. L.; SAKAI, P.
    Endoscopic submucosal dissection (ESD) of extensive superficial cancers of the esophagus may progress with high rates of postoperative stenosis, resulting in significantly decreased quality of life. Several therapies are performed to prevent this, but have not yet been compared in a systematic review. A systematic review of the literature and meta-analysis were performed using the MEDLINE, Embase, Cochrane, LILACS, Scopus, and CINAHL databases. Clinical trials and observational studies were searched from March 2014 to February 2015. Search terms included: endoscopy, ESD, esophageal stenosis, and esophageal stricture. Three retrospective and four prospective (three randomized) cohort studies were selected and involved 249 patients with superficial esophageal neoplasia who underwent ESD, at least two-thirds of the circumference. We grouped trials comparing different techniques to prevent esophagus stenosis post-ESD. We conducted different meta-analyses on randomized clinical trials (RCT), non-RCT, and global analysis. In RCT (three studies, n = 85), the preventive therapy decreased the risk of stenosis (risk difference = -0.36, 95 % CI -0.55 to -0.18, P = 0.0001). Two studies (one randomized and one non-randomized, n = 55) showed that preventative therapy lowered the average number of endoscopy dilatations (mean difference = -8.57, 95 % CI -13.88 to -3.25, P < 0.002). There were no significant differences in the three RCT studies (n = 85) in complication rates between patients with preventative therapy and those without (risk difference = 0.02, 95 % CI -0.09 to 0.14, P = 0.68). The use of preventive therapy after extensive ESD of the esophagus reduces the risk of stenosis and the number of endoscopic dilatations for resolution of stenosis without increasing the number of complications.
  • article
    Duodenal adenoma surveillance in patients with familial adenomatous polyposis
    (2015) CAMPOS, Fabio Guilherme; SULBARAN, Marianny; SAFATLE-RIBEIRO, Adriana Vaz; MARTINEZ, Carlos Augusto Real
    Familial adenomatous polyposis (FAP) is a hereditary disorder caused by Adenomatous Polyposis Gene mutations that lead to the development of colorectal polyps with great malignant risk throughout life. Moreover, numerous extracolonic manifestations incorporate different clinical features to produce varied individual phenotypes. Among them, the occurrence of duodenal adenomatous polyps is considered an almost inevitable event, and their incidence rates increase as a patient's age advances. Although the majority of patients exhibit different grades of duodenal adenomatosis as they age, only a small proportion (1%-5%) of patients will ultimately develop duodenal carcinoma. Within this context, the aim of the present study was to review the data regarding the epidemiology, classification, genetic features, endoscopic features, carcinogenesis, surveillance and management of duodenal polyps in patients with FAP.