LUIZ FERNANDO CANEO

(Fonte: Lattes)
Índice h a partir de 2011
13
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina - Médico
LIM/11 - Laboratório de Cirurgia Cardiovascular e Fisiopatologia da Circulação, Hospital das Clínicas, Faculdade de Medicina
LIM/65, Hospital das Clínicas, Faculdade de Medicina - Líder

Resultados de Busca

Agora exibindo 1 - 10 de 13
  • article 2 Citação(ões) na Scopus
    Pre-validation Study of the Brazilian Version of the Disruptions in Surgery Index (DiSI) as a Safety Tool in Cardiothoracic Surgery
    (2017) NINA, Vinicius Jose da Silva; JATENE, Fabio B.; SEVDALIS, Nick; MEJIA, Omar Asdrubal Vilca; BRANDAO, Carlos Manuel de Almeida; MONTEIRO, Rosangela; CANEO, Luiz Fernando; SCUDELLER, Paula Gobi; MENDES, Augusto Dimitry; MENDES, Vinicius Giuliano; ROMANO, Bellkiss Wilma
    Introduction: Most risk stratification scores used in surgery do not include external and non-technical factors as predictors of morbidity and mortality. Objective: The present study aimed to translate and adapt transculturally the Brazilian version of the Disruptions in Surgery Index (DiSI) questionnaire, which was developed to capture the self-perception of each member of the surgical team regarding the disruptions that may contribute to error and obstruction of safe surgical flow. Methods: A universalist approach was adopted to evaluate the conceptual equivalence of items and semantics, which included the following stages: (1) translation of the questionnaire into Portuguese; (2) back translation into English; (3) panel of experts to draft the preliminary version; and (4) pre-test for evaluation of verbal comprehension by the target population of 43 professionals working in cardiothoracic surgery. Results: The questionnaire was translated into Portuguese and its final version with 29 items obtained 89.6% approval from the panel of experts. The target population evaluated all items as easy to understand. The mean overall clarity and verbal comprehension observed in the pre-test reached 4.48 +/- 0.16 out of the maximum value of 5 on the psychometric Likert scale. Conclusion: Based on the methodology used, the experts' analysis and the results of the pre-test, it is concluded that the essential stages of translation and cross-cultural adaptation of DiSI to the Portuguese language were satisfactorily fulfilled in this study.
  • article 3 Citação(ões) na Scopus
    Impact of Vacuum-Assisted Venous Drainage on Forward Flow in Simulated Pediatric Cardiopulmonary Bypass Circuits Utilizing a Centrifugal Arterial Pump Head
    (2020) GUIMARAES, Daniel Peres; CANEO, Luiz Fernando; MATTE, Gregory S.; CARLETTO, Luciana P.; POLICARPO, Valeria Camargo; CASTRO, Ana Vitoria C. X.; MIRANDA, Matheus H. C.; COSTA, Priscila S.; JATENE, Marcelo B.; CESTARI, Idagene; JATENE, Fabio B.
    Objective: To analyze the impact of vacuum-assisted venous drainage (VAVD) on arterial pump flow in a simulated pediatric cardiopulmonary bypass circuit utilizing a centrifugal pump (CP) with an external arterial filter. Methods: The simulation circuit consisted of a Quadrox-I Pediatric oxygenator, a Rotaflow CP (Maquet Cardiopulmonary AG, Rastatt, Germany), and a custom pediatric tubing set primed with Lactated Ringer's solution and packed red blood cells. Venous line pressure, reservoir pressure, and arterial flow were measured with VAVD turned off to record baseline values. Four other conditions were tested with progressively higher vacuum pressures (-20, -40, -60, and -80 mmHg) applied to the baseline cardiotomy pressure. An arterial filter was placed into the circuit and arterial flow was measured with the purge line in both open and closed positions. These trials were repeated at set arterial flow rates of 1500, 2000, and 2500 mL/min. Results: The use of progressively higher vacuum caused a reduction in effective arterial flow from 1490 +/- 0.00 to 590 +/- 0.00, from 2020 +/- 0.01 to 1220 +/- 0.00, and from 2490 +/- 0.0 to 1830 +/- 0.01 mL/min. Effective forward flow decreased with increased levels of VAVD. Conclusion: The use of VAVD reduces arterial flow when a CP is used as the main arterial pump. The reduction in the forward arterial flow increases as the vacuum level increases. The loss of forward flow is further reduced when the arterial filter purge line is kept in the recommended open position. An independent flow probe is essential to monitor pump flow during cardiopulmonary bypass.
  • article
    Lessons Learned From a Critical Analysis of the Fontan Operation Over Three Decades in a Single Institution
    (2017) CANEO, Luiz Fernando; TURQUETTO, Aida L. R.; NEIROTTI, Rodolfo A.; BINOTTO, Maria A.; MIANA, Leonardo A.; TANAMATI, Carla; PENHA, Juliano G.; SILVEIRA, Joao B. D.; SILVA, Thais M. Alexandre e; JATENE, Fabio B.; JATENE, Marcelo B.
    Background: The Fontan operation (FO) has evolved and many centers have demonstrated improved results relative to those from earlier eras. We report a single-institution experience over three decades, describing the outcomes and evaluating risk factors. Methods: Successive patients undergoing primary FO were divided into era I (1984-1994), era II (1995-2004), and era III (2005-2014). Clinical and operative notes were reviewed for demographic, anatomic, and procedure details. End points included early and late mortality and a composite of death, heart transplantation (HTX), or Fontan takedown. Results: A total of 420 patients underwent 18 atriopulmonary connections, 82 lateral tunnels (LT), and 320 extracardiac conduit (EC) Fontan procedures. Forty-six (11%) patients died; early and late mortality were 7.9% and 3.1%, respectively. Eight (1.9%) patients underwent HTX, 11 (2.6%) underwent Fontan conversion to EC, and 1 (0.2%) takedown of EC to bidirectional Glenn shunt. Prevalence of concomitant valve surgery (P < .001) and pulmonary artery reconstruction (P < .001) differed over the eras. Preoperative valve regurgitation was associated with likelihood of early mortality (odds ratio [OR] = 3.5, P = .002). Embolic events (OR = 1.9, P = .047), preoperative valve regurgitation (OR = 2.3, P = .029), diagnosis of unbalanced atrioventricular canal defect (OR = 1.14, P = .03), and concomitant valve replacement (OR = 6.9, P = .001) during the FO were associated with increased risk of the composite end point (death, HTX, or takedown). Conclusion: Technical modifications did not result in improved results across eras, due in part to more liberal indications for surgery in the recent years. Valve regurgitation, unbalanced atrioventricular canal, embolic events, or concomitant valve replacement were associated with FO failure.
  • article 4 Citação(ões) na Scopus
    Translation and Validation of the Boston Technical Performance Score in a Developing Country
    (2021) MIANA, Leonardo A.; NATHAN, Meena; TENORIO, Davi Freitas; MANUEL, Valdano; GUERREIRO, Gustavo; FERNANDES, Natalia; CAMPOS, Carolina Vieira de; V, Paula Gaiolla; CASSAR, Renata Sa; TURQUETTO, Aida; AMATO, Luciana; CANEO, Luiz Fernando; DARODA, Larissa Leitao; JATENE, Marcelo Biscegli; JATENE, Fabio B.
    Introduction: The Technical Performance Score (TPS) was developed and subsequently refined at the Boston Children's Hospital. Our objective was to translate and validate its application in a developing country. Methods: The score was translated into the Portuguese language and approved by the TPS authors. Subsequently, we studied 1,030 surgeries from June 2018 to October 2020. TPS could not be assigned in 58 surgeries, and these were excluded. Surgical risk score was evaluated using Risk Adjustment in Congenital Heart Surgery (or RACHS-1). The impact of TPS on outcomes was studied using multivariable linear and logistic regression adjusting for important perioperative covariates. Results: Median age and weight were 2.2 (interquartile range [IQR] = 0.5-13) years and 10.8 (IQR = 5.6-40) kilograms, respectively. In-hospital mortality was 6.58% (n=64), and postoperative complications occurred in 19.7% (n=192) of the cases. TPS was categorized as 1 in 359 cases (37%), 2 in 464 (47.7%), and 3 in 149 (15.3%). Multivariable analysis identified TPS class 3 as a predictor of longer hospital stay (coefficient: 6.6; standard error: 2.2; P=0.003), higher number of complications (odds ratio [OR]: 1.84; 95% confidence interval [CI]: 1.1-3; P=0.01), and higher mortality (OR: 3.2; 95% CI: 1.4-7; P=0.004). Conclusion: TPS translated into the Portuguese language was validated and showed to be able to predict higher mortality, complication rate, and prolonged postoperative hospital stay in a high-volume Latin-American congenital heart surgery program. TPS is generalizable and can be used as an outcome assessment tool in resource diverse settings.
  • article 5 Citação(ões) na Scopus
    Functional Performance of Different Venous Limb Options in Simulated Neonatal/Pediatric Cardiopulmonary Bypass Circuits
    (2018) CANEO, Luiz Fernando; MATTE, Gregory S.; GUIMARAES, Daniel Peres; VIOTTO, Guilherme; MAZZETO, Marcelo; CESTARI, Idagene; NEIROTTI, Rodolfo A.; JATENE, Marcelo B.; WANG, Shigang; UNDAR, Akif; CHANG JUNIOR, Joao; JATENE, Fabio B.
    Objective: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. Methods: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16"" ID venous limbs (Circuit A) or to a single 1/4"" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4"" ID venous limbs (Circuit C) or a single 3/8"" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36 degrees C and 28 degrees C. Results: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. Conclusion: A single 1/4"" venous limb is better than dual 3/16"" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8"" venous limb is better than dual 1/4"" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.
  • article 1 Citação(ões) na Scopus
    Rational Use of Mechanical Circulatory Support as a Bridge to Pediatric and Congenital Heart Transplantation
    (2018) MIANA, Leonardo A.; SILVA, Guilherme Viotto Rodrigues da; CANEO, Luiz Fernando; TURQUETTO, Aida Luisa; TANAMATI, Carla; FORONDA, Gustavo; MASSOTI, Maria Raquel; PENHA, Juliano G.; AZEKA, Estela; GALAS, Filomena R. B. G.; JATENE, Fabio B.; JATENE, Marcelo B.
    Introduction: Donor shortage and organ allocation is the main problem in pediatric heart transplant. Mechanical circulatory support is known to increase waiting list survival, but it is not routinely used in pediatric programs in Latin America. Methods: All patients listed for heart transplant and supported by a mechanical circulatory support between January 2012 and March 2016 were included in this retrospective single-center study. The endpoints were mechanical circulatory support time, complications, heart transplant survival and discharge from the hospital. Results: Twenty-nine patients from our waiting list were assessed. Twelve (45%) patients were initially supported by extracorporeal membrane oxygenation (ECMO) and a centrifugal pump was implanted in 17 (55%) patients. Five patients initially supported by ECMO were bridged to another device. One was bridged to a centrifugal pump and four were bridged to Berlin Heart Excor (R). Among the 29 supported patients, 18 (62%) managed to have a heart transplant. Thirty-day survival period after heart transplant was 56% (10 patients). Median support duration was 12 days (interquartile range [IQR] 4-26 days) per run and the waiting time for heart transplant was 9.5 days (IQR 2.5-25 days). Acute kidney injury was identified as a mortality predictor (OR=22.6 [CI=1.04-494.6]; P=0.04). Conclusion: Mechanical circulatory support was able to bridge most INTERMACS 1 and 2 pediatric patients to transplant with an acceptable complication rate. Acute renal failure increased mortality after mechanical circulatory support in our experience.
  • article 7 Citação(ões) na Scopus
    In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach
    (2017) WANG, Shigang; CANEO, Luiz F.; JATENE, Marcelo B.; JATENE, Fabio B.; CESTARI, Idagene A.; KUNSELMAN, Allen R.; UNDAR, Akif
    The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygenator or a Maquet Quadrox-I Pediatric oxygenator without integrated arterial filter (parallel arrangement), 1/4 in. ID tubing A-V loop, and a 12-Fr arterial cannula, primed with lactated Ringer's solution and packed red blood cells. Trials were conducted at flow rates ranging from 500 to 2000 mL/min (500 mL/min increment) at 35 degrees C and 28 degrees C. Real-time pressure and flow data were recorded using a custom-based data acquisition system. ForGME testing, 5 cc of air was manually injected into the venous line. GME were recorded using the Emboli Detection and Classification Quantifier (EDAC) System. An additional experiment using a separate arterial filter was conducted. There was no difference in the mean circuit pressure, pressure drop, total hemodynamic energy level, and energy loss between the two oxygenators. The venous line pressures were higher in the Braile than in the Quadrox group during all trials (P < 0.01). GME count and volume at pre-/post oxygenator and pre-cannula sites in the Quadrox were lower than the Braile group at high flow rates (P<0.05). In the additional experiment, an arterial filter captured a significant number of microemboli at all flow rates. The Braile Infant oxygenator has a matched hemodynamic characteristic with the Quadrox-i Pediatric oxygenator. The Quadrox-i has a better GME handling ability compared with the Braile Infant oxygenator. Regardless of type of oxygenator an additional arterial filter decreases the number of GME.
  • article 4 Citação(ões) na Scopus
    Impact of COVID-19 Pandemic in a Pediatric and Congenital Cardiovascular Surgery Program in Brazil
    (2021) MIANA, Leonardo A.; MANUEL, Valdano; CANEO, Luiz Fernando; STRABELLI, Tania Mara Varejao; ARITA, Elisandra Trevisan; MONTEIRO, Rosangela; JATENE, Marcelo Biscegli; JATENE, Fabio B.
    Introduction: The coronavirus disease 2019 (COVID-19) has negatively impacted healthcare services worldwide. We hypothesized that the pandemic would affect our case mix and mortality. Our objective was to study this impact. Methods: We retrospectively studied all patients who underwent congenital heart surgeries from March 21st to August 21st in 2019 and 2020 using the institutional electronic database. We compared demographic data, preoperative and postoperative length of stay (LOS), risk stratification using Risk Adjustment for Congenital Heart Surgery (RACHS) classification and outcomes in both periods. Results: We observed a 66.7% decrease in our surgical volume (285 x 95 patients). Patients operated in the pre-pandemic period were older (911.3 [174.8 - 5953.8] days-old) compared to the pandemic period (275 days-old; P<0.05). When the case mix was compared between periods, the percentage of neonatal surgery was increased in the pandemic era (8% x 21.1%; P<0.05), and the number of RACHS 1-2 surgeries decreased significantly (60.7 x 27.4%; P<0.05). Preoperative LOS was increased in the pandemic period (1.2 x 7 days; P=0.001). There was no significant increment in mortality (P=0.1). Two patients tested positive for COVID-19 in the postoperative period and both died. Conclusion: Our program observed a sudden decrease in surgical volume and a consequent increase in surgical complexity. There was a non-significant increment in mortality.
  • article 0 Citação(ões) na Scopus
    Initial experience with del Nido cardioplegia solution at a Pediatric and Congenital Cardiac Surgery Program in Brazil
    (2022) CANEO, Luiz Fernando; MATTE, Gregory S.; TURQUETTO, Aida Luiza R.; PEGOLLO, Luana Marques de Carvalho; MIGLIOLI, Maria Clara Amato; SOUZA, Gisele T. de; AMATO, Luciana Patrick; MIANA, Leonardo A.; MASSOTI, Maria Raquel B.; PENHA, Juliano G.; TANAMATI, Carla; JATENE, Marcelo B.; JATENE, Fabio B.
    Objective: The aim of this study was to evaluate outcome measures between our standard multidose cardioplegia protocol and a del Nido cardioplegia protocol in congenital heart surgery patients. Methods: Retrospective single-center study including 250 consecutive patients that received del Nido cardioplegia (DN group) with a mandatory reperfusion period of 30% of cross clamp time and 250 patients that received a modified St. Thomas' solution (ST group). Groups were matched by age, weight, gender, and Risk Adjustment for Congenital Heart Surgery (RACHS-1) scores. Preoperative hematocrit and oxygen saturation were also recorded. Outcomes analyzed were the vasoactive inotropic score (VIS), lactate, ventilation time, ventricular dysfunction with low cardiac output syndrome (LCOS), intensive care unit (ICU) length of stay (LOS), hospital LOS, bypass and aortic cross-clamp times, and in-hospital mortality. Results: Both groups were comparable demographically. Statistically significant differences (p <= 0.05) were noted for cardiac dysfunction with LCOS, hematocrit at end of surgery (p = 0.0038), VIS on ICU admission and at end of surgery (p = 0.0111), and ICU LOS (p = 0.00118) with patients in the DN group having more desirable values for those parameters. Other outcome measures did not reach statistical significance. Conclusion: In our congenital cardiac surgery population, del Nido cardioplegia strategy was associated with less ventricular dysfunction with LCOS, a lower VIS and decreased ICU LOS compared with patients that received our standard myocardial protection using a modified St. Thomas' solution. Despite the limitation of this study, including its retrospective nature and cohort size, these data supported our transition to incorporate del Nido cardioplegia solution with a mandatory reperfusion period as the preferred myocardial protection method in our program.
  • article 6 Citação(ões) na Scopus
    Preoperative Neutrophil-Lymphocyte Ratio Can Predict Outcomes for Patients Undergoing Tetralogy of Fallot Repair
    (2021) MANUEL, Valdano; MIANA, Leonardo A.; GUERREIRO, Gustavo Pampolha; TURQUETTO, Aida; SANTOS, Romullo Medeiros; FERNANDES, Natalia; TENORIO, Davi Freitas; CANEO, Luiz Fernando; JATENE, Fabio B.; JATENE, Marcelo Biscegli
    Introduction: Elevated neutrophil-lymphocyte ratio (NLR) has been associated with poorer outcomes in cyanotic patients undergoing single ventricle palliation. Little is known about this biomarker on patients with tetralogy of Fallot (TOF), the most common cyanotic congenital heart disease. Our objective is to study the impact of preoperative NLR on outcomes of TOF patients undergoing total repair. Methods: This retrospective study included 116 consecutive patients between January 2014 and December 2018. Preoperative NLR was measured from the last complete blood count test before the surgery. Using the cutoff value of 0.80, according to the receiver-operating characteristic (ROC) curve, the sample was divided into two groups (NLR < 0.80 and >= 0.80). The primary endpoint was hospital length of stay (LOS). Results: ROC curves showed that higher preoperative NLR was associated with longer hospital LOS, with an area under the curve of 0.801 +/- 0.040 (95% confidence interval 0.722 - 0.879; P<0.001). High preoperative NLR was also associated with long intensive care unit (ICU) LOS (P=0.035). Preoperative NLR predicted longer hospital LOS with a sensitivity of 63% and a specificity of 81.4%. Conclusion: Higher preoperative NLR was associated with long ICU and hospital LOS in patients undergoing TOF repair.