GEORGE BARBERIO COURA FILHO

(Fonte: Lattes)
Índice h a partir de 2011
11
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Câncer do Estado de São Paulo, Hospital das Clínicas, Faculdade de Medicina - Médico
LIM/43 - Laboratório de Medicina Nuclear, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 7 de 7
  • article 6 Citação(ões) na Scopus
    Estimating 131I biokinetics and radiation doses to the red marrow and whole body in thyroid cancer patients: probe detection versus image quantification
    (2016) WILLEGAIGNON, José; PELISSONI, Rogério Alexandre; LIMA, Beatriz Christine de Godoy Diniz; SAPIENZA, Marcelo Tatit; COURA-FILHO, George Barberio; QUEIROZ, Marcelo Araújo; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To compare the probe detection method with the image quantification method when estimating 131I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients. Materials and Methods: Fourteen patients with metastatic thyroid cancer, without metastatic bone involvement, were submitted to therapy planning in order to tailor the therapeutic amount of 131I to each individual. Whole-body scans and probe measurements were performed at 4, 24, 48, 72, and 96 h after 131I administration in order to estimate the effective half-life (Teff) and residence time of 131I in the body. Results: The mean values for Teff and residence time, respectively, were 19 ± 9 h and 28 ± 12 h for probe detection, compared with 20 ± 13 h and 29 ± 18 h for image quantification. The average dose to the red marrow and whole body, respectively, was 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq for probe detection, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq for image quantification. Statistical analysis proved that there were no significant differences between the two methods for estimating the Teff (p = 0.801), residence time (p = 0.801), dose to the red marrow (p = 0.708), and dose to the whole body (p = 0.811), even when we considered an optimized approach for calculating doses only at 4 h and 96 h after 131I administration (p > 0.914). Conclusion: There is full agreement as to the feasibility of using probe detection and image quantification when estimating 131I biokinetics and red-marrow/whole-body doses. However, because the probe detection method is inefficacious in identifying tumor sites and critical organs during radionuclide therapy and therefore liable to skew adjustment of the amount of 131I to be administered to patients under such therapy, it should be used with caution.
  • article 1 Citação(ões) na Scopus
    Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
    (2015) VALADARES, Agnes Araujo; DUARTE, Paulo Schiavom; WOELLNER, Eduardo Bechtloff; COURA-FILHO, George Barberio; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Objective: To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on 18FNaF PET/CT scans. Materials and Methods: A total of 254 18F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses covered 675 regions classified as normal (236 RH, 232 RF, and 207 LV1). Results: Mean SUV for each skeletal region was 3.8, 5.4 and 14.4 for RH, RF, and LV1, respectively. As the studies were grouped according to mAs value, the mean SUV values were 3.8, 3.9 and 3.7 for 10, 20 and 30 mAs, respectively, in the RH region; 5.4, 5.5 and 5.4 for 10, 20 and 30 mAs, respectively, in the RF region; 13.8, 14.9 and 14.5 for 10, 20 and 30 mAs, respectively, in the LV1 region. Conclusion: The three tube current values yielded similar results for SUV calculation.
  • article 9 Citação(ões) na Scopus
    O SUS na medicina nuclear do Brasil: avaliação e comparação dos dados fornecidos pelo Datasus e CNEN
    (2014) POZZO, Lorena; COURA FILHO, George; OSSO JÚNIOR, João Alberto; SQUAIR, Peterson Lima
    Objective: To investigate the outpatient access to nuclear medicine procedures by means of the Brazilian Unified Health System (SUS), analyzing the correspondence between data provided by this system and those from Comissão Nacional de Energia Nuclear (CNEN) (National Commission of Nuclear Energy). Materials and Methods: Data provided by Datasus regarding number of scintillation chambers, outpatient procedures performed from 2008 to 2012, administrative responsibility for such procedures, type of service providers and outsourced services were retrieved and evaluated. Also, such data were compared with those from institutions certified by CNEN. Results: The present study demonstrated that the system still lacks maturity in terms of correct data input, particularly regarding equipment available. It was possible to list the most common procedures and check the growth of the specialty along the study period. Private centers are responsible for most of the procedures covered and reimbursed by SUS. However, many healthcare facilities are not certified by CNEN. Conclusion: Datasus provides relevant data for analysis as done in the present study, although some issues still require attention. The present study has quantitatively depicted the Brazilian reality regarding access to nuclear medicine procedures offered by/for SUS.
  • article 5 Citação(ões) na Scopus
    Bone marrow uptake of 18F-fluorodeoxyglucose in Hodgkin lymphoma without bone involvement: comparison between patients with and without B symptoms
    (2018) VALE, Rômulo Hermeto Bueno do; FERRARO, Daniela Andrade; DUARTE, Paulo Schiavom; CARVALHO, Giovana; LIMA, Marcos Santos; COURA FILHO, George Barbério; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To compare the degree of benign bone marrow uptake of 18F-fluorodeoxyglucose (18F-FDG) between Hodgkin lymphoma patients with and without B symptoms. Materials and Methods: We analyzed the medical charts of 74 Hodgkin lymphoma patients who underwent 18F-FDG positron emission tomography/computed tomography (PET/CT) prior to the initiation of therapy between October 2010 and September 2013. In all of the patients, the bone marrow biopsy was negative and the 18F-FDG PET/CT images did not suggest bone marrow involvement. Of the 74 patients evaluated, 54 presented inflammatory (B) symptoms and 20 did not. Regions of interest (ROIs) were drawn on the sternum, the proximal thirds of the humeri, the proximal thirds of the femora, and both iliac wings (totaling seven ROIs per patient). To compare the patients with and without B symptoms, in terms of standardized uptake values (SUVs) for the seven ROIs, we used the Mann-Whitney U test. Results: For six of the ROIs, the SUVs were higher in the patients with B symptoms than in those without, and the difference was statistically significant (p < 0.05). There was also a tendency toward a statistically significant difference between the two groups in terms of the SUV for the right iliac wing ROI (p = 0.06). Conclusion: In our sample, the presence of B symptoms was associated with increased 18F-FDG uptake in bone marrow.
  • article 2 Citação(ões) na Scopus
    Radiation safety measures in diagnostic nuclear medicine, based on the potential radiation dose emitted by radioactive patients
    (2023) WILLEGAIGNON, José; FERNANDES, Samantha Cristina Pereira; PELISSONI, Rogério Alexandre; COURA-FILHO, George Barbério; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To measure the potential radiation dose emitted by patients who have recently undergone diagnostic nuclear medicine procedures, in order to establish optimal radiation safety measures for such procedures. Materials and Methods: We evaluated the radiation doses emitted by 175 adult patients in whom technetium-99m, iodine-131, and fluorine-18 radionuclides were administered for bone, kidney, heart, brain, and whole-body scans, as measured with a radiation detector. Those values served as the basis for evaluating whole-body radiopharmaceutical clearance, as well as the risk for the exposure of others to radiation, depending on the time elapsed since administration of the radiopharmaceutical. Results: The mean time to clearance of the radiopharmaceuticals administered, expressed as the effective half-life, ranged from 1.18 ± 0.30 h to 11.41 ± 0.02 h, and the mean maximum cumulative radiation dose at 1.0 m from the patients was 149.74 ± 56.72 µSv. Even at a distance of 0.5 m, the cumulative dose was found to be only half and one tenth of the limits established for exposure of the general public and family members/caregivers (1.0 mSv and 5.0 mSv per episode, respectively). Conclusion: Cumulative radiation doses emitted by patients immediately after diagnostic nuclear medicine procedures are considerably lower than the limits established by the International Commission on Radiological Protection and the International Atomic Energy Agency, and precautionary measures to avoid radiation exposure are therefore not required after such procedures.
  • article 2 Citação(ões) na Scopus
    Dose calibrator linearity test: 99mTc versus 18F radioisotopes
    (2015) WILLEGAIGNON, José; SAPIENZA, Marcelo Tatit; COURA-FILHO, George Barberio; GARCEZ, Alexandre Teles; ALVES, Carlos Eduardo Gonzalez Ribeiro; CARDONA, Marissa Anabel Rivera; GUTTERRES, Ricardo Fraga; BUCHPIGUEL, Carlos Alberto
    Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.
  • article 4 Citação(ões) na Scopus
    Receiver operating characteristic (ROC) curve for classification of18F-NaF uptake on PET/CT
    (2016) VALADARES, Agnes Araujo; DUARTE, Paulo Schiavom; CARVALHO, Giovanna; ONO, Carla Rachel; COURA-FILHO, George Barberio; SADO, Heitor Naoki; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To assess the cutoff values established by ROC curves to classify18F-NaF uptake as normal or malignant. Materials and Methods: PET/CT images were acquired 1 hour after administration of 185 MBq of18F-NaF. Volumes of interest (VOIs) were drawn on three regions of the skeleton as follows: proximal right humerus diaphysis (HD), proximal right femoral diaphysis (FD) and first vertebral body (VB1), in a total of 254 patients, totalling 762 VOIs. The uptake in the VOIs was classified as normal or malignant on the basis of the radiopharmaceutical distribution pattern and of the CT images. A total of 675 volumes were classified as normal and 52 were classified as malignant. Thirty-five VOIs classified as indeterminate or nonmalignant lesions were excluded from analysis. The standardized uptake value (SUV) measured on the VOIs were plotted on an ROC curve for each one of the three regions. The area under the ROC (AUC) as well as the best cutoff SUVs to classify the VOIs were calculated. The best cutoff values were established as the ones with higher result of the sum of sensitivity and specificity. Results: The AUCs were 0.933, 0.889 and 0.975 for UD, FD and VB1, respectively. The best SUV cutoffs were 9.0 (sensitivity: 73%; specificity: 99%), 8.4 (sensitivity: 79%; specificity: 94%) and 21.0 (sensitivity: 93%; specificity: 95%) for UD, FD and VB1, respectively. Conclusion: The best cutoff value varies according to bone region of analysis and it is not possible to establish one value for the whole body.