ANDERSON VICENTE DE PAULA

Índice h a partir de 2011
7
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina
LIM/52 - Laboratório de Virologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • article 25 Citação(ões) na Scopus
    Evaluation of serological cross-reactivity between yellow fever and other flaviviruses
    (2019) SOUZA, Nathalia Caroline Santiago e; FELIX, Alvina Clara; PAULA, Anderson Vicente de; LEVI, Jose Eduardo; PANNUTI, Claudio Sergio; ROMANO, Camila Malta
    Objectives: This study was performed to determine whether neutralizing antibodies against yellow fever virus (YFV) generated by YFV vaccine could interfere in the specificity of dengue virus (DENV) and Zika virus (ZIKV) IgG ELISA tests. Methods: Seventy-nine pairs of serum samples (pre- and post-vaccination), collected during the years 1997-1998 from children with no history of yellow fever disease who had been vaccinated against YFV, were tested. The seroconversion post-vaccination was evaluated through plaque reduction neutralization test (PRNT), and four different commercial ELISA kits were used for the detection of DENV and ZIKV IgG antibodies. Results: A cross-reactivity rate of 3.9% with DENV IgG antibodies was found only with the Dengue Virus IgG Dx Select kit (Focus Diagnostics). Conclusions: As several countries have local transmission of multiple arboviruses, the absence of cross-reactivity or minimum cross-reactivity of YFV neutralizing antibodies with DENV and ZIKV antigens is a relevant finding, since the interpretation of sero-epidemiological investigations would be seriously impacted in many regions where YFV vaccination is mandatory. (C) 2019 The Authors.
  • article 12 Citação(ões) na Scopus
    Zika virus infection among symptomatic patients from two healthcare centers in Sao Paulo State, Brazil: prevalence, clinical characteristics, viral detection in body fluids and serodynamics
    (2019) TOZETTO-MENDOZA, Tania Regina; AVELINO-SILVA, Vivian Iida; FONSECA, Silvia; CLARO, Ingra Morales; PAULA, Anderson Vicente de; LEVIN, Anna Sara; SABINO, Ester Cerdeira; MENDES-CORREA, Maria Cassia; FIGUEIREDO, Walter Manso; FELIX, Alvina Clara; SOUZA, Nathalia C. Santiago; COSTA, Angela Aparecida; INENAMI, Maria; SILVA, Rosangela M. Gasparetto da; LEVI, Jose Eduardo; ROMANO, Camila Malta; PARANHOS-BACCALA, Glaucia; SEGURADO, Aluisio Cotrim; MAYAUD, Philippe
    Zika virus (ZIKV) clinical presentation and frequency/duration of shedding need further clarification. Symptomatic ZIKV-infected individuals identified in two hospitals in Sao Paulo State, Brazil, were investigated regarding clinical characteristics, shedding in body fluids, and serodynamics. Ninety-four of 235 symptomatic patients (Site A: 58%; Site B: 16%) had Real-Time PCR-confirmed ZIKV infection; fever, headache and gastrointestinal symptoms were less frequent, and rash was more frequent compared to ZIKV-negative patients. Real-Time PCR in serum had worse performance compared to plasma, while urine had the highest sensitivity. Shedding in genital fluids and saliva was rare. IgM positivity was the highest <14 days after the symptoms onset (86%), decreasing >28 days (24%); IgG positivity increased >14 days (96%) remaining positive in 94% of patients >28 days. ZIKV prevalence varied importantly in two neighboring cities during the same transmission season. Urine Real-Time PCR can improve diagnostic sensitivity; serum testing is less useful. Accurate serological tests are needed to improve diagnosis and surveillance.
  • article 4 Citação(ões) na Scopus
    Modulated Zika virus NS1 conjugate offers advantages for accurate detection of Zika virus specific antibody in double antigen binding and Ig capture enzyme immunoassays
    (2019) TEDDER, Richard S.; DICKS, Steve; IJAZ, Samreen; SOUZA, Nathalia Caroline Santiago de; PAULA, Anderson Vincente de; LEVY, Flavia; MEDIALDEA-CARRERA, Raquel; LEVI, Jose Eduardo; PANNUTI, Claudio S.; SEQUEIRA, Patricia Carvalho de; BROWN, David W. G.; LUMB, Ines Ushiro
    The accurate diagnosis and seroprevalence investigations of Zika virus (ZKV) infections remain complex due to cross reactivity with other flaviviruses. Two assay formats, both using labelled Zika virus NS1 antigen as a revealing agent (a double antigen binding assay, DABA, and an immunoglobulin Ig capture assay, G capture) were initially developed and compared with the indirect EuroimmunZ assay for the detection of anti-Zika antibody. Of 147 pre-Zika period serum samples, 39 (27%) were reactive in the EuroimmunZ or the DABA assays, 28 sera concordantly so. Such false reactivity was influenced by the serotype of Dengue virus (DV) to which individuals had been exposed to. Thus, of sera from patients undergoing secondary Dengue virus infection of known serotype, 91%, 45% and 28% of Dengue virus serotype 2, 3 and 4 respectively were reactive in one or more of the three assays. A novel method of quenching false sero-reactivity was therefore developed for the DABA and G capture assays. Initial addition of a single homologous Dengue virus serotype 3 NS1Ag quench significantly ablated false reactivities in the pre-Zika period sera. An equipotent quadrivalent quench comprising homologous Dengue virus serotypes 1 to 4 NS1Ag was shown to be optimum yet retained sensitivity for the detection of specific anti-Zika antibody. Comparing DABA and G capture assays using quenched and unquenched conjugates in comparison with EuroimmunZ early in the course of PCR-confirmed infection indicated that a significant component of the apparent early anti-ZIKA antibody response is likely to be due to a Zika virus-driven anamnestic anti-Dengue virus response. The increased specificity provided by homologous antigen quenching is likely to provide a significant improvement in sero-diagnostics and to be of clinical value.