    Validation of automated image co-registration integrated into in-house software for voxel-based internal dosimetry on single-photon emission computed tomography images
    (2023) LEITÃO, André Luiz Alberti; FONDA, Uysha de Souza; BUCHPIGUEL, Carlos Alberto; WILLEGAIGNON, José; SAPIENZA, Marcelo Tatit
    Abstract Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in relation to the bed axis), with and without a fiducial marker. Two rigid co-registration software packages-SPM12 and NMDose-coreg-were employed, and the percent root mean square error (%RMSE) was calculated in order to assess the quality of the co-registrations. Uniformity, contrast, and resolution were measured before and after co-registration. The NMDose-coreg software was employed to calculate the renal doses in 12 patients treated with 177Lu-DOTATATE, and we compared those with the values obtained with the Organ Level INternal Dose Assessment for EXponential Modeling (OLINDA/EXM) software. Results: The use of a fiducial marker had no significant effect on the quality of co-registration on SPECT images, as measured by %RMSE (p = 0.40). After co-registration, uniformity, contrast, and resolution did not differ between the images acquired with fiducial markers and those acquired without. Preliminary clinical application showed mean total processing times of 9 ± 3 min/patient for NMDose-coreg and 64 ± 10 min/patient for OLINDA/EXM, with a strong correlation between the two, despite the lower renal doses obtained with NMDose-coreg. Conclusion: The use of NMDose-coreg allows fast co-registration of SPECT images, with no loss of uniformity, contrast, or resolution. The use of a fiducial marker does not appear to increase the accuracy of co-registration on phantoms.
  • article 2 Citação(ões) na Scopus
    Radiation safety measures in diagnostic nuclear medicine, based on the potential radiation dose emitted by radioactive patients
    (2023) WILLEGAIGNON, José; FERNANDES, Samantha Cristina Pereira; PELISSONI, Rogério Alexandre; COURA-FILHO, George Barbério; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To measure the potential radiation dose emitted by patients who have recently undergone diagnostic nuclear medicine procedures, in order to establish optimal radiation safety measures for such procedures. Materials and Methods: We evaluated the radiation doses emitted by 175 adult patients in whom technetium-99m, iodine-131, and fluorine-18 radionuclides were administered for bone, kidney, heart, brain, and whole-body scans, as measured with a radiation detector. Those values served as the basis for evaluating whole-body radiopharmaceutical clearance, as well as the risk for the exposure of others to radiation, depending on the time elapsed since administration of the radiopharmaceutical. Results: The mean time to clearance of the radiopharmaceuticals administered, expressed as the effective half-life, ranged from 1.18 ± 0.30 h to 11.41 ± 0.02 h, and the mean maximum cumulative radiation dose at 1.0 m from the patients was 149.74 ± 56.72 µSv. Even at a distance of 0.5 m, the cumulative dose was found to be only half and one tenth of the limits established for exposure of the general public and family members/caregivers (1.0 mSv and 5.0 mSv per episode, respectively). Conclusion: Cumulative radiation doses emitted by patients immediately after diagnostic nuclear medicine procedures are considerably lower than the limits established by the International Commission on Radiological Protection and the International Atomic Energy Agency, and precautionary measures to avoid radiation exposure are therefore not required after such procedures.
  • article 2 Citação(ões) na Scopus
    Dose calibrator linearity test: 99mTc versus 18F radioisotopes
    (2015) WILLEGAIGNON, José; SAPIENZA, Marcelo Tatit; COURA-FILHO, George Barberio; GARCEZ, Alexandre Teles; ALVES, Carlos Eduardo Gonzalez Ribeiro; CARDONA, Marissa Anabel Rivera; GUTTERRES, Ricardo Fraga; BUCHPIGUEL, Carlos Alberto
    Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.