MARCOS EDUARDO LERA DOS SANTOS

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina - Médico

Resultados de Busca

Agora exibindo 1 - 10 de 28
  • article 1 Citação(ões) na Scopus
    Managing adverse events after endoscopic ultrasound-guided drainage of the biliary tract and pancreatic fluid collections: Narrative review (with video)
    (2022) FUNARI, Mateus Pereira; RIBEIRO, Igor Braga; SANTOS, Marcos Eduardo Lera dos; MATUGUMA, Sergio Eiji; MOURA, Eduardo Guimaraes Hourneaux de
    Endoscopic ultrasound (EUS)-guided therapeutic procedures have become increasingly common in clinical practice. The development of EUS-guided fine needle aspiration cytology led to the concept of interventional EUS. However, it carries a considerable risk of adverse events (AEs), which occur in approximately 23% of the procedures performed for the drainage of pancreatic fluid collections and 2.5-37.0% of those performed for drainage of the biliary tract. Although the vast majority of AEs occurring after EUS-guided drainage are mild, a deep understanding of such events is necessary for their appropriate management. Because EUS-guided drainage is a novel procedure, there have been few studies of the topic. To our knowledge, this is the first narrative review that focuses on the management and resolution of AEs occurring after EUS-guided drainage of pancreatic fluid collections or the biliary tract. We also include an explanatory video.
  • article 0 Citação(ões) na Scopus
    Acute esophageal necrosis (black esophagus) with active upper gastrointestinal bleeding: What to do?
    (2021) RIBEIRO, Igor Braga; LUZ, Gustavo de Oliveira; SOUZA, Gabriel Mayo Vieira de; BOGHOSSIAN, Mateus Bond; MONTE JUNIOR, Epifanio Silvino do; SANTOS, Marcos Eduardo Lera dos; MOURA, Eduardo Guimaraes Hourneaux de
  • article 24 Citação(ões) na Scopus
    A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis
    (2018) GUEDES, Hugo Goncalo; MOURA, Diogo Turiani Hourneaux de; DUARTE, Ralph Braga; CORDERO, Martin Andres Coronel; SANTOS, Marcos Eduardo Lera dos; CHENG, Spencer; MATUGUMA, Sergio Eiji; CHAVES, Dalton Marques; BERNARDO, Wanderley Marques; MOURA, Eduardo Guimaraes Hourneaux de
    Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 studies were found in the search, among which 4 randomized studies were selected for inclusion in the analysis. A total of 462 patients were evaluated (233: 25G needle/229: 22G needle). The diagnostic sensitivity was 93% for the 25G needle and 91% for the 22G needle. The specificity of the 25G needle was 87%, and that of the 22G needle was 83%. The positive likelihood ratio was 4.57 for the 25G needle and 4.26 for the 22G needle. The area under the sROC curve for the 25G needle was 0.9705, and it was 0.9795 for the 22G needle, with no statistically significant difference between them (p=0.497). Based on randomized studies, this meta-analysis did not demonstrate a significant difference between the 22G and 25G needles used during EUS-FNA in the diagnosis of solid pancreatic lesions.
  • article 1 Citação(ões) na Scopus
    Pure Cut or Endocut for Biliary Sphincterotomy? A Multicenter Randomized Clinical Trial
    (2023) FUNARI, Mateus Pereira; BRUNALDI, Vitor Ottoboni; PROENCA, Igor Mendonca; GOMES, Pedro Victor Aniz; QUEIROZ, Lucas Tobias Almeida; VIEIRA, Yuri Zamban; MATUGUMA, Sergio Eiji; IDE, Edson; FRANZINI, Tomazo Antonio Prince; SANTOS, Marcos Eduardo Lera dos; CHENG, Spencer; MINATA, Mauricio Kazuyoshi; SANTOS, Jose Sebastio dos; MOURA, Diogo Turiani Hourneaux de; KEMP, Rafael; MOURA, Eduardo Guimares Hourneaux de
    INTRODUCTION: Adverse events (AE) after endoscopic retrograde cholangiopancreatography (ERCP) are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger PEP or bleeding. Therefore, this study evaluated the outcomes of 2 electric current modes used during biliary sphincterotomy. METHODS: From October 2019 to August 2021, consecutive patients with native papilla undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation. RESULTS: A total of 550 patients were randomized (272 pure cut and 278 endocut). The overall PEP rate was 4.0% and significantly higher in the endocut group (5.8% vs 2.2%, P = 0.034). Univariate analysis revealed >5 attempts (P = 0.004) and endocut mode (P = 0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (P = 0.005) and a trend for endocut mode as risk factors for PEP (P = 0.052). Intraprocedural bleeding occurred more often with pure cut (P = 0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with endocut (P = 0.047). There was no difference in perforation (P = 1.0) or infection (P = 0.4999) between the groups. DISCUSSION: Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCT assessing the impact of electric current on AE with overlapping preventive measures such as rectal nonsteroidal anti-inflammatory drugs and hyperhydration are needed. The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.
  • article 4 Citação(ões) na Scopus
    II Brazilian consensus statement on endoscopic ultrasonography
    (2017) MALUF-FILHO, Fauze; OLIVEIRA, Joel Fernandez de; MENDONCA, Ernesto Quaresma; CARBONARI, Augusto; MACIENTE, Bruno Antonio; SALOMAO, Bruno Chaves; MEDRADO, Bruno Frederico; DOTTI, Carlos Marcelo; LOPES, Cesar Vivian; BRAGA, Claudia Utsch; DUTRA, Daniel Alencar M.; RETES, Felipe; NAKAO, Frank; SOUSA, Giovana Biasia de; PAULO, Gustavo Andrade de; ARDENGH, Jose Celso; SANTOS, Juliana Bonfim dos; SAMPAIO, Luciana Moura; OKAWA, Luciano; ROSSINI, Lucio; CARDOSO, Manoel Carlos de Brito; CAMUNHA, Marco Antonio Ribeiro; CLARENCIO, Marcos; SANTOS, Marcos Eduardo Lera dos; FRANCO, Matheus; SCHNEIDER, Nutianne Camargo; MASCARENHAS, Ramiro; RODA, Rodrigo; MATUGUMA, Sergio; GUARALDI, Simone; FIGUEIREDO, Viviane
    Background and Objectives: At the time of its introduction in the early 80s, endoscopic ultrasonography (EUS) was indicated for diagnostic purposes. Recently, EUS has been employed to assist or to be the main platform of complex therapeutic interventions. Methods: From a series of relevant new topics in the literature and based on the need to complement the I Brazilian consensus on EUS, twenty experienced endosonographers identified and reviewed the pertinent literature in databases. The quality of evidence, strength of recommendations, and level of consensus were graded and voted on. Results: Consensus was reached for eight relevant topics: treatment of gastric varices, staging of nonsmall cell lung cancer, biliary drainage, tissue sampling of subepithelial lesions (SELs), treatment of pancreatic fluid collections, tissue sampling of pancreatic solid lesions, celiac neurolysis, and evaluation of the incidental pancreatic cysts. Conclusions: There is a high level of evidence for staging of nonsmall cell lung cancer; biopsy of SELs as the safest method; unilateral and bilateral injection techniques are equivalent for EUS-guided celiac neurolysis, and in patients with visible ganglia, celiac ganglia neurolysis appears to lead to better results. There is a moderate level of evidence for: yield of tissue sampling of pancreatic solid lesions is not influenced by the needle shape, gauge, or employed aspiration technique; EUS-guided and percutaneous biliary drainage present similar clinical success and adverse event rates; plastic and metallic stents are equivalent in the EUS-guided treatment of pancreatic pseudocyst. There is a low level of evidence in the routine use of EUS-guided treatment of gastric varices.
  • article 0 Citação(ões) na Scopus
    The feared postdilation complication in caustic esophageal stenosis: combined endoscopic and surgical treatment
    (2021) SAGAE, Vitor Massaro Takamatsu; RIBEIRO, Igor Braga; PONTE NETO, Alberto Machado da; MATUGUMA, Sergio Eiji; CHENG, Spencer; SANTOS, Marcos Eduardo Lera dos; MOURA, Eduardo Guimaraes Hourneaux de
  • article 8 Citação(ões) na Scopus
    Pancreatitis after endoscopic retrograde cholangiopancreatography: A narrative review
    (2021) RIBEIRO, Igor Braga; MONTE JUNIOR, Epifanio Silvino do; MIRANDA NETO, Antonio Afonso; PROENCA, Igor Mendonca; MOURA, Diogo Turiani Hourneaux de; MINATA, Mauricio Kazuyoshi; IDE, Edson; SANTOS, Marcos Eduardo Lera dos; LUZ, Gustavo de Oliveira; MATUGUMA, Sergio Eiji; CHENG, Spencer; BARACAT, Renato; MOURA, Eduardo Guimaraes Hourneaux de
    Acute post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is a feared and potentially fatal complication that can be as high as up to 30% in high-risk patients. Pre-examination measures, during the examination and after the examination are the key to technical and clinical success with a decrease in adverse events. Several studies have debated on the subject, however, numerous topics remain controversial, such as the effectiveness of prophylactic medications and the amylase dosage time. This review was designed to provide an update on the current scientific evidence regarding PEP available in the literature.
  • bookPart
    Ecoendoscopia terapêutica
    (2014) ARTIFON, Everson Luiz de Almeida; SANTOS, Marcos Eduardo Lera dos; CHENG, Spencer; MATUGUMA, Sergio Eiji
  • article
    Endoscopic Treatment of Complex Walled-Off Necrosis in Necrotizing Pancreatitis With Two Simultaneous Lumen-Apposing Metal Stents: A Case Report
    (2022) SANTOS, Marcos Eduardo Lera dos; PROENCA, Igor Mendonca; SASSO, Joao Guilherme Ribeiro Jordao; OLIVEIRA, Victor Lira de; RIBAS, Pedro Henrique Boraschi Vieira; BESTETTI, Alexandre Moraes; RIBEIRO, Igor Braga; ANNA, Raoni Salomao Sant; OLIVEIRA, Guilherme Henrique Peixoto de; MOURA, Eduardo Guimaraes Hourneaux de
    Organized pancreatic and peripancreatic collections are complications of pancreatitis and should be treated when symptomatic or complicated. When feasible, the endoscopic ultrasound approach presents high efficacy and low morbidity and mortality, making it the first likely option. Among the available accessories for endoscopic drainage, the lumen-apposing metal stent can be a better option, with a low migration rate; furthermore, it allows endoscopic necrosectomy. Here, we present the case of complex walled-off necrosis treated with two lumen-apposing metal stents in the same procedure. A 41-year-old male patient with walled-off necrosis presented with delayed gastric emptying and obstruction of the main biliary duct. Magnetic resonance imaging and endoscopic ultrasound revealed two non-communicating collections. We opted for endoscopic ultrasound-guided drainage with the deployment of two simultaneous lumen-apposing metal stents: one transduodenal and the other transgastric, with clinical improvement. After three weeks, endoscopic retrograde cholangiopancreatography showed a biliary fistula communicating with the periduodenal collection, which was treated with a biliary plastic stent. An endoscopic necrosectomy was performed, and the metal stents were removed. Control magnetic resonance imaging demonstrated improvement. The patient was asymptomatic at the six-month follow-up. The treatment of symptomatic complex walled-off necrosis remains a challenge and may require multiple endoscopic approaches; moreover, surgical treatment may be necessary in case of failure. In the present report, we demonstrate that the deployment of two lumen-apposing metal stents in the same procedure is feasible when necessary as it was associated with technical success and short-term clinical success.
  • article 33 Citação(ões) na Scopus
    Efficacy of digital single-operator cholangioscopy in the visual interpretation of indeterminate biliary strictures: a systematic review and meta-analysis
    (2020) OLIVEIRA, Pedro Victor Aniz Gomes de; MOURA, Diogo Turiani Hourneaux de; RIBEIRO, Igor Braga; BAZARBASHI, Ahmad Najdat; FRANZINI, Tomazo Antonio Prince; SANTOS, Marcos Eduardo Lera dos; BERNARDO, Wanderley Marques; MOURA, Eduardo Guimaraes Hourneaux de
    Objective Indeterminate biliary strictures remain a significant diagnostic challenge. Digital single-operator cholangioscopy (D-SOC) incorporates digital imaging which enables higher resolution for better visualization and diagnosis of biliary pathology. We aimed to conduct a systematic review and meta-analysis of available literature in an attempt to determine the efficacy of D-SOC in the visual interpretation of indeterminate biliary strictures. Material and methods Electronic searches were performed using Medline (PubMed), EMBASE, and Cochrane Library. All D-SOC studies that reported the diagnostic performance in visual interpretation of indeterminate biliary strictures and biliary malignancies were included. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was used to evaluate the quality of the included studies. All data were extracted and pooled to construct a 2 x 2 table. The visual interpretation of D-SOC was compared to resected surgical specimens or clinical follow-up in the included patients. Pooled sensitivity, specificity, positive predictive value, negative predictive value, prevalence, positive likelihood ratio (+LR), negative likelihood ratio (-LR), and diagnostic odds ratio (OR) were calculated. The summarized receiver operating characteristic (SROC) curve corresponding with the area under the curve (AUC) was also analyzed. Results The search yielded 465 citations. Of these, only six studies with a total of 283 procedures met inclusion criteria and were included in the meta-analysis. The overall pooled sensitivity and specificity of D-SOC in the visual interpretation of biliary malignancies was 94% (95% CI 89-97) and 95% (95%CI 90-98), respectively, while +LR, -LR, diagnostic OR, and AUC were 15.20 (95%CI 5.21-44.33), 0.08 (95%CI 0.04-0.14), 308.83 (95%CI 106.46-872.82), and 0.983, respectively. The heterogeneity among 6 included studies was moderate for specificity (I-2 = 0.51) and low for sensitivity (I-2 = 0.17) and diagnostic OR (I-2 = 0.00). Conclusion D-SOC is associated with high sensitivity and specificity in the visual interpretation of indeterminate biliary strictures and malignancies. D-SOC should be considered routinely in the diagnostic workup of indeterminate biliary lesions.