RENATA MOTA MAMEDE CARVALLO

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
Departamento de Fisioterapia, Fonoaudiologia e Terapia Ocupacional, Faculdade de Medicina - Docente
LIM/34 - Laboratório de Ciências da Reabilitação, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • article 7 Citação(ões) na Scopus
    Alteration of distortion product otoacoustic emission input/output functions in subjects with a previous history of middle ear dysfunction
    (2012) CAMPOS, Ualace De P.; SANCHES, Seisse G.; HATZOPOULOS, Stavros; CARVALLO, Renata M. M.; KOCHANEK, Krzysztof; SKARZYNSKI, Henryk
    Background: The aim of this study was to investigate the effects of sub-clinical alterations on the amplitudes and slopes of the DPOAE input-output responses from subjects with previous history of middle ear dysfunction. Material/Methods: The study included 15 subjects with and 15 subjects without a history of otitis media in the last 10 years. All participants were assessed with acoustic immittance, pure-tone audiometry, and DPOAEs. For the later, I/O functions and I/O slopes were estimated at 1501, 2002, 3174, 4004 and 6384Hz. Results: No statistically significant differences were found between the 2 groups in terms of behavioral thresholds. The group with a previous history of middle ear dysfunction presented significantly lower mean DPOAE amplitudes at 2002, 3174 and 4004 Hz. In terms of DPOAE slopes, no statistically significant differences were observed at the tested frequencies, except at 3174 Hz. Conclusions: Middle ear pathologies can produce subclinical alterations that are undetectable with traditional pure-tone audiometry. The data from the present study show that reduced amplitude DPOAEs are associated with a previous history of middle ear complications. The corresponding DPOAE slopes were affected at only 1 tested frequency, suggesting that the cochlear non-linearity is preserved. Considering these results, it remains to be elucidated to what degree the DPOAE amplitude attenuation interferes with higher-order auditory tasks.
  • article 2 Citação(ões) na Scopus
    Relationship Between Distortion Product - Otoacoustic Emissions (DPOAEs) and High-Frequency Acoustic Immittance Measures
    (2016) CAMPOS, Ualace De Paula; HATZOPOULOS, Stavros; SLIWA, Lech K.; SKARZYNSKI, Piotr H.; JEDRZEJCZAK, Wieslaw W.; SKARZYNSKI, Henryk; CARVALLO, Renata Mota Mamede
    Background: Pathologies that alter the impedance of the middle ear may consequently modify the DPOAE amplitude. The aim of this study was to correlate information from 2 different clinical procedures assessing middle ear status. Data from DPOAE responses (both DP-Gram and DP I/O functions) were correlated with data from multi-component tympanometry at 1000 Hz. Material/Methods: The subjects were divided into a double-peak group (DPG) and a single-peak group (SPG) depending on 1000 Hz tympanogram pattern. Exclusion criteria (described in the Methods section) were applied to both groups and finally only 31 ears were assigned to each group. The subjects were also assessed with traditional tympanometry and behavioral audiometry. Results: Compared to the single-peak group, in terms of the 226 Hz tympanometry data, subjects in the DPG group presented: (i) higher values of ear canal volume; (ii) higher peak pressure, and (iii) significantly higher values of acoustic admittance. DPOAE amplitudes were lower in the DPG group only at 6006 Hz, but the difference in amplitude between the DPG and SPG groups decreased as the frequency increased. Statistical differences were observed only at 1001 Hz and a borderline difference at 1501 Hz. In terms of DPOAE I/O functions, significant differences were observed only in 4 of the 50 tested points. Conclusions: The 1000-Hz tympanometric pattern significantly affects the structure of DPOAE responses only at 1001 Hz. In this context, changes in the properties of the middle ear (as detected by the 1000 Hz tympanometry) can be considered as prime candidates for the observed variability in the DP-grams and the DP I/O functions.
  • article 1 Citação(ões) na Scopus
    Contralateral suppression of otoacoustic emissions: Input-Output functions in neonates
    (2011) CAMPOS, Ualace De Paula; HATZOPOULOS, Stavros; KOCHANEK, Krzysztof; SLIWA, Lech; SKARZYNSKI, Henryk; CARVALLO, Renata Mota Mamede
    Background: The literature suggests that contralateral acoustic stimulation (CAS) alters the amplitude of the distortion product otoacoustic emissions (DPOAEs), but it is still unknown whether the DPOAE Input/Output (I/O) functions are also affected. To elucidate this aspect of the DPOAEs, the present study assessed the effects of CAS on DPOAE I/O functions at the frequencies of 2 kHz and 4 kHz, in a sample of term neonatal subjects. Material/Methods: Sixty randomly selected neonates were included in the study. The DPOAE I/O functions were obtained at 2 kHz and 4 kHz, in the presence of a 60 dB SPL broad band-contralateral white noise, using the TDH39 headphones contralaterally. DPOAEs were recorded up to a stimulus level of L(2)=35 dB peSPL. Results: Significant DPOAE amplitude suppression effects were observed at various L(2) stimulus levels for both tested frequencies at 2 and 4 kHz. In contrast, the corresponding DPOAE slopes showed various alterations that were not statistically significant. Conclusions: The data from the present study show that contralateral acoustic stimulation significantly affects only the amplitude of the DPOAE I/O functions; the slope is affected, but not significantly. This observation can shed light on the nature of CAS, suggesting that the latter is primarily a linear phenomenon without the cochlear compression and non-linear components seen in the healthy cochlea. From the available data it is not possible to infer whether the sample size has influenced the obtained results and the study should be repeated with a larger sample size and assessing more frequencies.