GUILHERME VIOTTO RODRIGUES DA SILVA

Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina - Médico

Resultados de Busca

Agora exibindo 1 - 4 de 4
  • article 5 Citação(ões) na Scopus
    Functional Performance of Different Venous Limb Options in Simulated Neonatal/Pediatric Cardiopulmonary Bypass Circuits
    (2018) CANEO, Luiz Fernando; MATTE, Gregory S.; GUIMARAES, Daniel Peres; VIOTTO, Guilherme; MAZZETO, Marcelo; CESTARI, Idagene; NEIROTTI, Rodolfo A.; JATENE, Marcelo B.; WANG, Shigang; UNDAR, Akif; CHANG JUNIOR, Joao; JATENE, Fabio B.
    Objective: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. Methods: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16"" ID venous limbs (Circuit A) or to a single 1/4"" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4"" ID venous limbs (Circuit C) or a single 3/8"" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36 degrees C and 28 degrees C. Results: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. Conclusion: A single 1/4"" venous limb is better than dual 3/16"" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8"" venous limb is better than dual 1/4"" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.
  • article 1 Citação(ões) na Scopus
    Rational Use of Mechanical Circulatory Support as a Bridge to Pediatric and Congenital Heart Transplantation
    (2018) MIANA, Leonardo A.; SILVA, Guilherme Viotto Rodrigues da; CANEO, Luiz Fernando; TURQUETTO, Aida Luisa; TANAMATI, Carla; FORONDA, Gustavo; MASSOTI, Maria Raquel; PENHA, Juliano G.; AZEKA, Estela; GALAS, Filomena R. B. G.; JATENE, Fabio B.; JATENE, Marcelo B.
    Introduction: Donor shortage and organ allocation is the main problem in pediatric heart transplant. Mechanical circulatory support is known to increase waiting list survival, but it is not routinely used in pediatric programs in Latin America. Methods: All patients listed for heart transplant and supported by a mechanical circulatory support between January 2012 and March 2016 were included in this retrospective single-center study. The endpoints were mechanical circulatory support time, complications, heart transplant survival and discharge from the hospital. Results: Twenty-nine patients from our waiting list were assessed. Twelve (45%) patients were initially supported by extracorporeal membrane oxygenation (ECMO) and a centrifugal pump was implanted in 17 (55%) patients. Five patients initially supported by ECMO were bridged to another device. One was bridged to a centrifugal pump and four were bridged to Berlin Heart Excor (R). Among the 29 supported patients, 18 (62%) managed to have a heart transplant. Thirty-day survival period after heart transplant was 56% (10 patients). Median support duration was 12 days (interquartile range [IQR] 4-26 days) per run and the waiting time for heart transplant was 9.5 days (IQR 2.5-25 days). Acute kidney injury was identified as a mortality predictor (OR=22.6 [CI=1.04-494.6]; P=0.04). Conclusion: Mechanical circulatory support was able to bridge most INTERMACS 1 and 2 pediatric patients to transplant with an acceptable complication rate. Acute renal failure increased mortality after mechanical circulatory support in our experience.
  • article 7 Citação(ões) na Scopus
    Early and Long-Term Outcomes of Surgical Treatment of Ebstein's Anomaly
    (2019) SILVA, Guilherme Viotto Rodrigues da; MIANA, Leonardo Augusto; CANEO, Luiz Fernando; TURQUETTO, Aida Luiza Ribeiro; TANAMATI, Carla; PENHA, Juliano G.; JATENE, Fabio B.; JATENE, Marcelo B.
    Objective: This study aimed to evaluate Ebstein's anomaly surgical correction and its early and long-term outcomes. Methods: A retrospective analysis of 62 consecutive patients who underwent surgical repair of Ebstein's anomaly in our institution from January 2000 to July 2016. The following long-term outcomes were evaluated: survival, reoperations, tricuspid regurgitation, and postoperative right ventricular dysfunction. Results: Valve repair was performed in 46 (74.2%) patients - 12 of them using the Da Silva cone reconstruction; tricuspid valve replacement was performed in 11 (17.7%) patients; univentricular palliation in one (1.6%) patient; and the one and a half ventricle repair in four (6.5%) patients. The patients' mean age at the time of surgery was 20.5 +/- 14.9 years, and 46.8% of them were male. The mean follow-up time was 8.8 +/- 6 years. The 30-day mortality rate was 8.06% and the one and 10-year survival rates were 91.9% both. Eleven (17.7%) of the 62 patients required late reoperation due to tricuspid regurgitation, in an average time of 7.1 +/- 4.9 years after the first procedure. Conclusion: In our experience, the long-term results of the surgical treatment of Ebstein's anomaly demonstrate an acceptable survival rate and a low incidence of reinterventions.
  • article 1 Citação(ões) na Scopus
    Outcomes of the Conversion of the Fontan-Kreutzer Operation to a Total Cavopulmonary Connection for the Failing Univentricular Circulation
    (2019) FERNANDES, Gabriel Carmona; SILVA, Guilherme Viotto Rodrigues da; CANEO, Luiz Fernando; TANAMATI, Carla; TURQUETTO, Aida Luiza Ribeiro; JATENE, Marcelo Biscegli
    Background: The Fontan-Kreutzer procedure (FK) was widely performed in the past, but in the long-term generated many complications resulting in univentricular circulation failure. The conversion to total cavopulmonary connection (TCPC) is one of the options for treatment. Objective: To evaluate the results of conversion from FK to TCPC. Methods: A retrospective review of medical records for patients who underwent the conversion of FK to TCPC in the period of 1985 to 2016. Significance p < 0,05. Results: Fontan-type operations were performed in 420 patients during this period: TCPC was performed in 320, lateral tunnel technique in 82, and FK in 18. Ten cases from the FK group were elected to conversion to TCPC. All patients submitted to Fontan Conversion were included in this study. In nine patients the indication was due to uncontrolled arrhythmia and in one, due to protein-losing enteropathy. Death was observed in the first two cases. The average intensive care unit (ICU) length of stay (LOS) was 13 days, and the average hospital LOS was 37 days. A functional class by New York Heart Association (NYHA) improvement was observed in 80% of the patients in NYHA I or II. Fifty-seven percent of conversions due to arrhythmias had improvement of arrhythmias; four cases are cured. Conclusions: The conversion is a complex procedure and requires an experienced tertiary hospital to be performed. The conversion has improved the NYHA functional class despite an unsatisfactory resolution of the arrhythmia.