Effect of a Perioperative Intra-Aortic Balloon Pump in High-Risk Cardiac Surgery Patients: A Randomized Clinical Trial
Carregando...
Citações na Scopus
19
Tipo de produção
article
Data de publicação
2018
Título da Revista
ISSN da Revista
Título do Volume
Editora
LIPPINCOTT WILLIAMS & WILKINS
Autores
LANDONI, Giovanni
VINCENT, Jean Louis
FOMINSKIY, Evgeny
Citação
CRITICAL CARE MEDICINE, v.46, n.8, p.E742-E750, 2018
Resumo
Objectives: The aim of this study was to evaluate the efficacy of perioperative intra-aortic balloon pump use in high-risk cardiac surgery patients. Design: A single-center randomized controlled trial and a meta-analysis of randomized controlled trials. Setting: Heart Institute of SAo Paulo University. Patients: High-risk patients undergoing elective coronary artery bypass surgery. Intervention: Patients were randomized to receive preskin incision intra-aortic balloon pump insertion after anesthesia induction versus no intra-aortic balloon pump use. Measurements and Main Results: The primary outcome was a composite endpoint of 30-day mortality and major morbidity (cardiogenic shock, stroke, acute renal failure, mediastinitis, prolonged mechanical ventilation, and a need for reoperation). A total of 181 patients (mean [sd] age 65.4 [9.4] yr; 32% female) were randomized. The primary outcome was observed in 43 patients (47.8%) in the intra-aortic balloon pump group and 42 patients (46.2%) in the control group (p = 0.46). The median duration of inotrope use (51hr [interquartile range, 32-94 hr] vs 39hr [interquartile range, 25-66 hr]; p = 0.007) and the ICU length of stay (5 d [interquartile range, 3-8 d] vs 4 d [interquartile range, 3-6 d]; p = 0.035) were longer in the intra-aortic balloon pump group than in the control group. A meta-analysis of 11 randomized controlled trials confirmed a lack of survival improvement in high-risk cardiac surgery patients with perioperative intra-aortic balloon pump use. Conclusions: In high-risk patients undergoing cardiac surgery, the perioperative use of an intra-aortic balloon pump did not reduce the occurrence of a composite outcome of 30-day mortality and major complications compared with usual care alone.
Palavras-chave
cardiac surgery, intra-aortic balloon pump, meta-analysis, morbidity, mortality, randomized controlled trial
Referências
- Baskett RJF, 2005, AM HEART J, V150, P1122, DOI 10.1016/j.ahj.2005.01.043
- Baskett RJF, 2003, ANN THORAC SURG, V76, P1988, DOI 10.1016/S0003-4975(03)01197-4
- Cheng JM, 2013, INT J CARDIOL, V168, P3758, DOI 10.1016/j.ijcard.2013.06.009
- Christenson JT, 1997, EUR J CARDIO-THORAC, V11, P1097, DOI 10.1016/S1010-7940(97)00087-0
- Christenson JT, 1997, ANN THORAC SURG, V64, P1237, DOI 10.1016/S0003-4975(97)00898-9
- Christenson JT, 2003, J CARDIAC SURG, V18, P286, DOI 10.1046/j.1540-8191.2003.02030.x
- Christenson JT, 1997, J CARDIOVASC SURG, V38, P397
- Christenson JT, 1999, ANN THORAC SURG, V68, P934, DOI 10.1016/S0003-4975(99)00687-6
- Cooley DA, 2000, CIRCULATION, V102, P87
- Dyub AM, 2008, J CARDIAC SURG, V23, P79, DOI 10.1111/j.1540-8191.2007.00499.x
- Hashemzadeh K, 2012, J CARDIOVASC SURG, V53, P387
- Higgins J. P., 2011, COCHRANE HDB SYSTEMA
- Lamy A, 2013, NEW ENGL J MED, V369, P196
- Lomivorotov VV, 2012, J CARDIOTHOR VASC AN, V26, P596, DOI 10.1053/j.jvca.2011.09.006
- Metz D, 2011, MED KLIN, V106, P125, DOI 10.1007/s00063-011-0048-z
- Moher D, 2009, PLOS MED, V6, DOI 10.1371/journal.pmed.1000097
- Ouweneel DM, 2017, J AM COLL CARDIOL, V69, P278, DOI 10.1016/j.jacc.2016.10.022
- Poirier Y, 2016, INT J CARDIOL, V207, P67, DOI 10.1016/j.ijcard.2016.01.045
- Prondzinsky R, 2012, SHOCK, V37, P378, DOI 10.1097/SHK.0b013e31824a67af
- Ranucci M, 2013, CRIT CARE MED, V41, P2476, DOI 10.1097/CCM.0b013e3182978dfc
- Scott BH, 2005, J CARDIOTHOR VASC AN, V19, P26, DOI 10.1053/j.jvca.2004.11.005
- Shahian DM, 2009, ANN THORAC SURG, V88, pS2, DOI 10.1016/j.athoracsur.2009.05.053
- Shi M, 2011, J INT MED RES, V39, P1163, DOI 10.1177/147323001103900404
- Thiele H, 2013, LANCET, V382, P1638, DOI 10.1016/S0140-6736(13)61783-3
- Unverzagt S, 2015, COCHRANE DB SYST REV, DOI 10.1002/14651858.CD007398.pub3
- Welsby IJ, 2002, ANESTH ANALG, V94, P1072, DOI 10.1097/00000539-200205000-00004
- Wilczynski M, 2010, KARDIOL POL, V68, P1361
- Zangrillo A, 2015, CRIT CARE, V19, DOI 10.1186/s13054-014-0728-1
Coleções
Artigos e Materiais de Revistas Científicas - FM/MCG
Artigos e Materiais de Revistas Científicas - FM/MCP
Artigos e Materiais de Revistas Científicas - HC/ICESP
Artigos e Materiais de Revistas Científicas - HC/InCor
Artigos e Materiais de Revistas Científicas - LIM/08
Artigos e Materiais de Revistas Científicas - LIM/11
Carregar mais Artigos e Materiais de Revistas Científicas - FM/MCP
Artigos e Materiais de Revistas Científicas - HC/ICESP
Artigos e Materiais de Revistas Científicas - HC/InCor
Artigos e Materiais de Revistas Científicas - LIM/08
Artigos e Materiais de Revistas Científicas - LIM/11