Sustained safety and clinical performance of a drug-eluting absorbable metal scaffold up to 24 months: pooled outcomes of BIOSOLVE-II and BIOSOLVE-III

Carregando...
Imagem de Miniatura
Citações na Scopus
121
Tipo de produção
article
Data de publicação
2017
Editora
EUROPA EDITION
Indexadores
Título da Revista
ISSN da Revista
Título do Volume
Autores
HAUDE, Michael
INCE, Huseyin
KISCHE, Stephan
ABIZAID, Alexandre
TOLG, Ralph
MIEGHEM, Nicolas M. Van
VERHEYE, Stefan
BIRGELEN, Clemens von
CHRISTIANSEN, Evald Hoj
Autor de Grupo de pesquisa
BIOSOLVE-II BIOSOLVE-III Investig
Editores
Coordenadores
Organizadores
Citação
EUROINTERVENTION, v.13, n.4, p.432-439, 2017
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
Aims: We aimed to assess the safety and performance of the DREAMS 20 scaffold up to 24 months post implant. Methods and results: The present study population comprises a total of 184 patients with 189 lesions who were enrolled in the prospective, multicentre BIOSOLVE-II and BIOSOLVE-III trials. Clinical follow-up was scheduled at one, six, 12, 24 and 36 months. The present report includes pooled follow-up data at six months and BIOSOLVE-II data at 24 months. Patients were 65.51 +/- 10.8 years old, and lesions were 12.5 +/- 5.1 mm long with reference diameters of 2.7 +/- 0.4 mm. Procedural success was obtained in 97.8%. At six months, the composite clinical endpoint target lesion failure was 3.3% (95% CI: 1.2-7.1), based on two cardiac deaths (1.1%, one unknown and one not device-related), one target vessel myocardial infarction (0.6%), and three clinically driven target lesion revascularisations (1.7%). For BIOSOLVE-II at 24 months, the target lesion failure rate was 5.9% (95% CI: 2.4-11.8), based on two cardiac deaths (1.7%), one target vessel myocardial infarction (0.9%) and four target lesion revascularisations (3.4%). There was no definite or probable scaffold thrombosis. Conclusions: The present analysis provides additional evidence on the safety of a drug-eluting absorbable metal scaffold with promising clinical outcomes up to 24 months and absence of definite or probable scaffold thrombosis.
Palavras-chave
bioresorbable scaffolds, myocardial infarction, stable angina, stent thrombosis
Referências
  1. Abizaid A, 2016, JACC-CARDIOVASC INTE, V9, P565, DOI 10.1016/j.jcin.2015.12.004
  2. Byrne RA, 2015, EUR HEART J, V36, P2608, DOI 10.1093/eurheartj/ehv203
  3. Capodanno D, 2017, JACC-CARDIOVASC INTE, V10, P425, DOI 10.1016/j.jcin.2016.12.279
  4. Chevalier B, 2016, EUROINTERVENTION, V12, P1102, DOI 10.4244/EIJY16M08_01
  5. Cutup DE, 2007, CIRCULATION, V115, P2344
  6. Eggebrecht H, 2005, CIRCULATION, V112, pE303, DOI 10.1161/CIRCULATIONAHA.104.521641
  7. Fajadet J, 2016, EUROINTERVENTION, V12, P828, DOI 10.4244/EIJV12I7A137
  8. Haude M, 2016, EUR HEART J, V37, P2701, DOI 10.1093/eurheartj/ehw196
  9. Haude M, 2016, EUROINTERVENTION, V12, pE160, DOI [10.4244/EIJ-D-15-00371, 10.4244/EIJY16M06_01]
  10. Haude M, 2016, LANCET, V387, P31, DOI 10.1016/S0140-6736(15)00447-X
  11. Lipinski MJ, 2016, JACC-CARDIOVASC INTE, V9, P12, DOI 10.1016/j.jcin.2015.09.024
  12. Moussa ID, 2013, J AM COLL CARDIOL, V62, P1563, DOI 10.1016/j.jacc.2013.08.720
  13. Mukherjee D, 2017, NEW ENGL J MED, V376, P2388, DOI 10.1056/NEJMe1703202
  14. Onuma Y, 2016, EUROINTERVENTION, V12, P1090, DOI 10.4244/EIJY16M09_01
  15. Raber L, 2015, J AM COLL CARDIOL, V66, P1901, DOI 10.1016/j.jacc.2015.08.853
  16. Schmidt W, 2016, CARDIOVASC REVASCULA, V17, P375, DOI 10.1016/j.carrev.2016.05.001
  17. Toyota T, 2017, JACC-CARDIOVASC INTE, V10, P27, DOI 10.1016/j.jcin.2016.10.027
  18. von Birgelen C, 2016, LANCET, V388, P2607, DOI 10.1016/S0140-6736(16)31920-1
  19. Waksman R, 2017, EUROINTERVENTION, V13, P440
  20. Waksman R, 2007, CATHETER CARDIO INTE, V70, P407, DOI 10.1002/ccd.21176
  21. Waksman R, 2009, JACC-CARDIOVASC INTE, V2, P312, DOI 10.1016/j.jcin.2008.09.015
  22. Windecker S, 2015, CIRC-CARDIOVASC INTE, V8, DOI 10.1161/CIRCINTERVENTIONS.114.001441
  23. Wykrzykowska JJ, 2017, NEW ENGL J MED, V376, P2319, DOI 10.1056/NEJMoa1614954