Endoscopic gastrostomy replacement tubes: Long-term randomized trial with five silicone commercial models

Carregando...
Imagem de Miniatura
Citações na Scopus
13
Tipo de produção
article
Data de publicação
2014
Editora
CHURCHILL LIVINGSTONE
Indexadores
Título da Revista
ISSN da Revista
Título do Volume
Autor de Grupo de pesquisa
Editores
Coordenadores
Organizadores
Citação
CLINICAL NUTRITION, v.33, n.2, p.221-225, 2014
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
Trial design: No analysis of the long-term performance of percutaneous endoscopic gastrostomy (PEG) replacement tubes was identified. A randomized partially blinded trial was designed hypothesizing that clinically relevant limitations of the tubes would be identified. Methods: Patients (N = 100, age 58.3 +/- 20.7 years, 42.0% males, time with PEG 27.0 +/- 22.5 months) were randomized in five parallel intervention groups, each with a tested device (Silmag (R), Bard (R), Freka (R), Kangaroo (R) and Wilson Cook (R)). Eligibility criteria included age 18-90 years, males and females, on home enteral nutrition, and the setting was a large academic hospital. Patients were allocated according to a random numbers list, and independent professionals were responsible for data collection. Primary outcome was tube longevity, calculated by Kaplan-Meier curves and Cox regression analysis. A sample of 18 was calculated based on a 10% effect size and 80% power. Results: Twenty patients were randomized in each group and all were analyzed. There was no morbidity and mortality, however tube dysfunction was common with all models. Fastener sliding occurred in 57.0% and balloon rupture in 32.0%, along with other mishaps. Best tube longevity corresponded to the Wilson Cook model (158.0 +/- 10.0 days, P < 0.05), mostly on account of diminished balloon ruptures. Conclusions: PEG replacement was safe however relatively frequent and affecting longevity, therefore longer-lasting tubes are needed. Specific attention should be given to cap, feeding line, external clamp, tube fastener; tube length, and notably balloon performance, which may be disappointing.
Palavras-chave
Percutaneous endoscopic gastrostomy, Replacement tubes, Longevity, Complications, Kaplan-Meier curves, Balloon rupture
Referências
  1. Akay B, 2010, J PEDIATR SURG, V45, P1147, DOI 10.1016/j.jpedsurg.2010.02.079
  2. Avery C, 2008, INT J ORAL MAX SURG, V37, P140, DOI 10.1016/j.ijom.2007.08.465
  3. Beres A, 2009, SEMIN PEDIAT SURG, V18, P87, DOI 10.1053/j.sempedsurg.2009.02.005
  4. Blacka J, 2004, ALIMENT PHARM THERAP, V20, P875, DOI 10.1111/j.1365-2036.2004.02191.x
  5. Broad JB, 2011, AGE AGEING, V40, P487, DOI 10.1093/ageing/afr056
  6. Campoli P, 2011, DIGEST ENDOSC, V23, P135, DOI 10.1111/j.1443-1661.2010.01051.x
  7. Eibach U, 2002, MED KLIN, V97, P558, DOI 10.1007/s00063-002-1196-y
  8. Gomes Jr CA, 2012, COCHRANE DB SYST REV, V3, DOI 10.1002/14651858.CD008096]
  9. Grant MD, 1998, JAMA-J AM MED ASSOC, V279, P1973, DOI 10.1001/jama.279.24.1973
  10. Horiuchi A, 2008, ENDOSCOPY, V40, P722, DOI 10.1055/s-2008-1077490
  11. James A, 1998, AGE AGEING, V27, P671, DOI 10.1093/ageing/27.6.671
  12. Nishiwaki S, 2011, GASTROINTEST ENDOSC, V74, P784, DOI 10.1016/j.gie.2011.05.032
  13. Rosenberger LH, 2011, SURG ENDOSC, V25, P3307, DOI 10.1007/s00464-011-1709-y
  14. Sartori S, 2003, ALIMENT PHARM THERAP, V17, P853, DOI 10.1046/j.0269-2813.2003.01538.x
  15. Schrag SP, 2007, J GASTROINTEST LIVER, V16, P407
  16. Shah Anish M, 2012, JOP, V13, P54
  17. Wilhelm SM, 2010, AM J SURG, V199, P396, DOI 10.1016/j.amjsurg.2009.08.023