Title: Comparison of Visual Acuity and Automated Perimetry Findings in Patients With Neuromyelitis Optica or Multiple Sclerosis After Single or Multiple Attacks of Optic Neuritis
Authors: FERNANDES, Danilo B.RAMOS, Renata de Iracema P.FALCOCHIO, CarolinaAPOSTOLOS-PEREIRA, SamiraCALLEGARO, DagobertoMONTEIRO, Mario Luiz Ribeiro
Citation: JOURNAL OF NEURO-OPHTHALMOLOGY, v.32, n.2, p.102-106, 2012
Abstract: Objective: To review the clinical characteristics of patients with neuromyelitis optica (NMO) and to compare their visual outcome with those of patients with optic neuritis (ON) and multiple sclerosis (MS). Methods: Thirty-three patients with NMO underwent neuro-ophthalmic evaluation, including automated perimetry along with 30 patients with MS. Visual function in both groups was compared overall and specifically for eyes after a single episode of ON. Results: Visual function and average visual field (VF) mean deviation were significantly worse in eyes of patients with NMO. After a single episode of ON, the VF was normal in only 2 of 36 eyes of patients with NMO compared to 17 of 35 eyes with MS (P < 0.001). The statistical analysis indicated that after a single episode of ON, the odds ratio for having NMO was 6.0 (confidence interval [CI]: 1.6-21.9) when VF mean deviation was worse than -20.0 dB while the odds ratio for having MS was 16.0 (CI: 3.6-68.7) when better than -3.0 dB. Conclusion: Visual outcome was significantly worse in NMO than in MS. After a single episode of ON, suspicion of NMO should be raised in the presence of severe residual VF deficit with automated perimetry and lowered in the case of complete VF recovery.
Appears in Collections:

Artigos e Materiais de Revistas Científicas - FM/MOF
Departamento de Otorrinolaringologia e Oftalmologia - FM/MOF

Artigos e Materiais de Revistas Científicas - HC/ICHC
Instituto Central - HC/ICHC

Artigos e Materiais de Revistas Científicas - LIM/33
LIM/33 - Laboratório de Oftalmologia

Artigos e Materiais de Revistas Científicas - LIM/45
LIM/45 - Laboratório de Fisiopatologia Neurocirúrgica


Files in This Item:
File Description SizeFormat 
art_FERNANDES_Comparison_of_Visual_Acuity_and_Automated_Perimetry_Findings_2012.PDF
  Restricted Access
publishedVersion (English)93.06 kBAdobe PDFView/Open Request a copy

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.