Please use this identifier to cite or link to this item: https://observatorio.fm.usp.br/handle/OPI/8941
Title: Accuracy of multidetector computed tomography for detection of coronary artery stenosis in acute coronary syndrome compared with stable coronary disease: A CORE64 multicenter trial substudy
Authors: SARA, LeonardoROCHITTE, Carlos E.LEMOS, Pedro A.NIINUMA, HiroyukiDEWEY, MarcSHAPIRO, Edward P.GOTTLIEB, IlanMANSUR, Antonio P.NICOLAU, Jose C.LARDO, Albert C.AZEVEDO, Clerio F.KALIL-FILHO, RobertoVAVERE, Andrea L.COHN, SilviaCOX, ChristopherBRINKER, JeffreyMILLER, Julie M.LIMA, Joao A. C.
Citation: INTERNATIONAL JOURNAL OF CARDIOLOGY, v.177, n.2, p.385-391, 2014
Abstract: Background: Multi-detector computed tomography angiography (MDCTA) is a promising method for risk assessment of patients with acute chest pain. However, its diagnostic performance in higher-risk patients has not been investigated in a large international multicenter trial. Therefore, in the present study we sought to estimate the diagnostic accuracy of MDCTA to detect significant coronary stenosis in patients with acute coronary syndrome (ACS). Methods: Patients included in the CORE64 study were categorized as suspected-ACS or non-ACS based on clinical data. A 64-row coronary MDCTA was performed before invasive coronary angiography (ICA) and both exams were evaluated by blinded, independent core laboratories. Results: From 371 patients included, 94 were categorized as suspected ACS and 277 as non-ACS. Patient-based analysis showed an area under the receiver-operating-characteristic curve (AUC) for detecting >= 50% coronary stenosis of 0.95 (95% CI: 0.88-0.98) in ACS and 0.92 (95% CI: 0.88-0.95) in non-ACS group (P = 0.29). The sensitivity, specificity, positive and negative predictive values of MDCTA were 0.90(0.80-0.96), 0.88(0.70-0.98), 0.95(0.87-0.99) and 0.77(0.58-0.90) in suspected ACS patients and 0.87(0.81-0.92), 0.86(0.79-0.92), 0.91(0.85-0.95) and 0.82(0.74-0.89) in non-ACS patients (P NS for all comparisons). The mean calcium scores (CS) were 282 +/- 449 in suspected ACS and 435 +/- 668 in non-ACS group. The accuracy of CS to detect significant coronary stenosis was only moderate and the absence or minimal coronary artery calcification could not exclude the presence of significant coronary stenosis, particularly in ACS patients. Conclusions: The diagnostic accuracy of MDCTA to detect significant coronary stenosis is high and comparable for both ACS and non-ACS patients.
Appears in Collections:

Artigos e Materiais de Revistas Científicas - FM/MCP
Departamento de Cardio-Pneumologia - FM/MCP

Artigos e Materiais de Revistas Científicas - HC/InCor
Instituto do Coração - HC/InCor

Artigos e Materiais de Revistas Científicas - LIM/11
LIM/11 - Laboratório de Cirurgia Cardiovascular e Fisiopatologia da Circulação

Artigos e Materiais de Revistas Científicas - ODS/03
ODS/03 - Saúde e bem-estar


Files in This Item:
File Description SizeFormat 
art_SARA_Accuracy_of_multidetector_computed_tomography_for_detection_of_2014.PDF
  Restricted Access
publishedVersion (English)589.6 kBAdobe PDFView/Open Request a copy

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.