TAISA GROTTA RAGAZZO

(Fonte: Lattes)
Índice h a partir de 2011
2
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/07 - Laboratório de Gastroenterologia Clínica e Experimental, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • article 16 Citação(ões) na Scopus
    Concordance of non-invasive mechanical and serum tests for liver fibrosis evaluation in chronic hepatitis C
    (2017) PARANAGUA-VEZOZZO, Denise C.; ANDRADE, Adriana; MAZO, Daniel F. C.; NUNES, Vinicius; GUEDES, Ana L.; RAGAZZO, Taisa G.; MOUTINHO, Renata; NACIF, Lucas S.; ONO, Suzane K.; ALVES, Venancio A. F.; CARRILHO, Flair J.
    AIM To determine the sensitivity and specificity of liver stiffness measurement (LSM) and serum markers (SM) for liver fibrosis evaluation in chronic hepatitis C. METHODS Between 2012 and 2014, 81 consecutive hepatitis C virus (HCV) patients had METAVIR score from liver biopsy compared with concurrent results from LSM [transient elastography (TE) [FibroScan (R)/ARFI technology (Virtual Touch (R))] and SM [FIB-4/aspartate aminotransferase-to-platelet ratio index (APRI)]. The diagnostic performance of these tests was assessed using receiver operating characteristic curves. The optimal cut-off levels of each test were chosen to define fibrosis stages F >= 2, F >= 3 and F = 4. The Kappa index set the concordance analysis. RESULTS Fifty point six percent were female and the median age was 51 years (30-78). Fifty-six patients (70%) were treatment-naive. The optimal cut-off values for predicting F >= 2 stage fibrosis assessed by TE were 6.6 kPa, for acoustic radiation force impulse (ARFI) 1.22 m/s, for APRI 0.75 and for FIB-4 1.47. For F >= 3 TE was 8.9 kPa, ARFI was 1.48 m/s, APRI was 0.75, and FIB-4 was 2. For F = 4, TE was 12.2 kPa, ARFI was 1.77 m/s, APRI was 1.46, and FIB-4 was 3.91. The APRI could not distinguish between F2 and F3, P = 0.92. The negative predictive value for F = 4 for TE and ARFI was 100%. Kappa index values for F >= 3 METAVIR score for TE, ARFI and FIB-4 were 0.687, 0.606 and 0.654, respectively. This demonstrates strong concordance between all three screening methods, and moderate to strong concordance between them and APRI (Kappa index = 0.507). CONCLUSION Given the costs and accessibility of LSM methods, and the similarity with the outcomes of SM, we suggest that FIB-4 as well as TE and ARFI may be useful indicators of the degree of liver fibrosis. This is of particular importance to developing countries.
  • article 42 Citação(ões) na Scopus
    Accuracy of transient elastography-FibroScan (R), acoustic radiation force impulse (ARFI) imaging, the enhanced liver fibrosis (ELF) test, APRI, and the FIB-4 index compared with liver biopsy in patients with chronic hepatitis C
    (2017) RAGAZZO, Taisa Grotta; PARANAGUA-VEZOZZO, Denise; LIMA, Fabiana Roberto; MAZO, Daniel Ferraz de Campos; PESSOA, Mario Guimaraes; OLIVEIRA, Claudia Pinto; ALVES, Venancio Avancini Ferreira; CARRILHO, Flair Jose
    OBJECTIVES: Although liver biopsy is the gold standard for determining the degree of liver fibrosis, issues regarding its invasiveness and the small amount of liver tissue evaluated can limit its applicability and interpretation in clinical practice. Non-invasive evaluation methods for liver fibrosis can address some of these limitations. The aim of this study was to evaluate the accuracy of transient elastography-FibroScan (R), acoustic radiation force impulse (ARFI), enhanced liver fibrosis (ELF), the aspartate aminotransferase-to-platelet ratio index (APRI), and the FIB-4 index compared with liver biopsy in hepatitis C. METHODS: We evaluated chronic hepatitis C patients who were followed at the Division of Clinical Gastroenterology and Hepatology, Hospital das Clinicas, Department of Gastroenterology of University of Sao Paulo School of Medicine, Sao Paulo, Brazil, and who underwent liver biopsy. The accuracy of each method was determined by a receiver operating characteristic (ROC) curve analysis, and fibrosis was classified as significant fibrosis (>= F2), advanced fibrosis (>= F3), or cirrhosis (F4). The Obuchowski method was also used to determine the diagnostic accuracy of each method at the various stages of fibrosis. In total, 107 FibroScan (R), 51 ARFI, 68 ELF, 106 APRI, and 106 FIB-4 analyses were performed. RESULTS: A total of 107 patients were included in the study. The areas under the ROC curve (AUROCs) according to fibrosis degree were as follows: significant fibrosis (>= F2): FibroScan (R) : 0.83, FIB-4: 0.76, ELF: 0.70, APRI: 0.69, and ARFI: 0.67; advanced fibrosis (>= F3): FibroScan (R) : 0.85, ELF: 0.82, FIB-4: 0.77, ARFI: 0.74, and APRI: 0.71; and cirrhosis (F4): APRI: 1, FIB-4: 1, FibroScan (R) : 0.99, ARFI: 0.96, and ELF: 0.94. The accuracies of transient elastography, ARFI, ELF, APRI and FIB-4 determined by the Obuchowski method were F0-F1: 0.81, 0.78, 0.44, 0.72 and 0.67, respectively; F1-F2: 0.73, 0.53, 0.62, 0.60, and 0.68, respectively; F2-F3: 0.70, 0.64, 0.77, 0.60, and 0.67, respectively; and F3-F4: 0.98, 0.96, 0.82, 1, and 1, respectively. CONCLUSION: Transient elastography remained the most effective method for evaluating all degrees of fibrosis. The accuracy of all methodologies was best at F4.
  • conferenceObject
    NON-INVASIVE ASSESSMENT ON HEPATIC FIBROSIS BEFORE AND AFTER HCV CURE AND CORRELATION WITH CLINICAL OUTCOMES
    (2021) RAGAZZO, Taisa Grotta; GARCIA-TSAO, Guadalupe; MAZO, Daniel; OLIVEIRA, Claudia P. M. S.; ZITELI, Patricia; SINGER, Julio Da Motta; CARRILHO, Flair J.; PESSOA, Mario