MARCELO HATANAKA

(Fonte: Lattes)
Índice h a partir de 2011
8
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/33 - Laboratório de Oftalmologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 8 de 8
  • article 2 Citação(ões) na Scopus
    Comparison of the hypotensor effect between latanoprost versus selective laser trabeculoplasty obtained with the water drinking test
    (2021) GERMANO, Renato Antunes Schiave; HATANAKA, Marcelo; GARCIA, Arthur Sonego; GERMANO, Flavio Augusto Schiave; GERMANO, Caroline Schiave; CID, Felipe Biscegli; GERMANO, Jorge Estefano
    Purpose: Glaucoma is the main cause of irreversible blindness worldwide. Peak intraocular pressure is one of the main risk factors for glaucoma progression, and intraocular pressure reduction remains the only therapeutic strategy for all types of glaucoma. The main purpose of our study was to compare the baseline and peak intraocular pressure reduction obtained with the water drinking test between the two eyes of the same patients using 0.005% latanoprost in one eye and selective laser trabeculoplasty application in the contralateral eye. Methods: This was a prospective, interventional, longitudinal, and randomized clinical trial, in which 30 consecutive glaucomatous patients, medically controlled using latanoprost monotherapy, were recruited from a single ophthalmological center. The patients' eyes were randomized, and one eye was selected for SLT treatment and topical 0.005% latanoprost was introduced in the contralateral eye. The baseline intraocular pressure and peak intraocular pressure were evaluated 1 month (water drinking test 2) and 6 months (water drinking test 3) after treatment. Results: There was no significant difference between the mean pre-washout intraocular pressure in the randomized eyes for selective laser trabeculoplasty and latanoprost (13.6 +/- 2.1 and 13.3 +/- 1.8 mmHg, respectively; p=0.182). Regarding baseline intraocular pressure, there was no significant difference in the water drinking test 2 (p=0.689) and water drinking test 3 (p=0.06) between the groups. There was no significant difference in the intraocular pressure peak between the SLT and latanoprost groups at water drinking test 2 (p=0.771) or water drinking test 3 (p=0.774). Conclusions: The intraocular pressure reduction efficacy is similar between latanoprost and selective laser trabeculoplasty. Glaucomatous patients who are medically controlled with latanoprost and switch treatment to selective laser trabeculoplasty maintain control of intraocular pressure.
  • article 0 Citação(ões) na Scopus
    The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug
    (2023) MACEDO, Marcelo; HATANAKA, Marcelo; BARBOZA, Wilma Lelis; MINGIONE, Gabriella Marranghello; AMBROSIO, Renato; JR, Remo Susanna
    This study aimed to investigate the effects of topical anesthetic and fluorescein drops on intraocular pressure (IOP), central corneal thickness (CCT) and biomechanical properties as measured by Corvis ST (CST-Oculus; Wezlar, Germany) in healthy eyes. A cross-sectional observational study was conducted on 46 healthy patients. The CST measurements were obtained before and immediately after the instillation of topical anesthetic and fluorescein drops. Pre-post instillation data were statistically analyzed. IOP measurements were compared to Goldmann's Applanation Tonometry (GAT), which was also performed after drops instillation. Biomechanical parameters analyzed included applanation 1 velocity, applanation 2 velocity, applanation 1 time, applanation 2 time, whole eye movement, deflection amplitude, and stiffness parameter at first applanation. A statistically significant difference in IOP, both for non-corrected IOP (IOPnct) and biomechanically corrected IOP (bIOP), was observed before and after the instillation of eyedrops. Despite this statistical significance, the observed difference lacked clinical relevance. The IOPnct demonstrated a significant difference pre and post-anesthetic and fluorescein instillation compared to GAT (14.99 +/- 2.27 mmHg pre-instillation and 14.62 +/- 2.50 mmHg post-instillation, versus 13.98 +/- 2.04 mmHg, with p-values of 0.0014 and 0.0490, respectively). Comparable findings were noted when justaposing bIOP to GAT (14.53 +/- 2.10 mmHg pre-instillation and 13.15 +/- 2.25 mmHg post-instillation, against 13.98 +/- 2.04 mmHg, with p-values of 0.0391 and 0.0022, respectively). Additionally, CCT measurements revealed a statistically significant elevation following the administration of topical anesthetic and fluorescein drops (from 544.64 +/- 39.85 mu m to 586.74 +/- 41.71 mu m, p < 0.01. None of the analyzed biomechanical parameters showed statistically significant differences after drops instillation. While the administration of topical anesthetic and fluorescein drops induced a statistically significant alteration in both IOPnct and bIOP readings, these changes were not clinically consequential. Furthermore, a notable statistical rise was observed in CCT measurements post-drops instillation, as determined by CST. Yet, corneal biomechanical parameters remained unaffected.
  • article 0 Citação(ões) na Scopus
    Effect of panretinal photocoagulation on the peripapillary retinal nerve fiber layer in diabetic retinopathy patients
    (2019) ZACHARIAS, Leandro Cabral; AZEVEDO, Breno M. S.; ARAUJO, Rafael B. de; CIONGOLI, Marina R.; HATANAKA, Marcelo; PRETI, Rony C.; MONTEIRO, Mario Luiz Ribeiro
    OBJECTIVES: To determine the effect of panretinal photocoagulation (PRP) on the peripapillary retinal nerve fiber layer (RNFL) in nonglaucomatous patients with proliferative diabetic retinopathy (PDR). METHODS: This is a prospective, single center, observational study. Thirty-eight eyes of 26 diabetic patients underwent PRP for proliferative diabetic retinopathy. Peripapillary RNFL thickness was measured using scanning laser polarimetry (SLP) with variable corneal compensation (GDx VCC; by Carl Zeiss Meditec, Dublin, CA) and spectral-domain optical coherence tomography (OCT) (Heidelberg Spectralis, Carlsbad, USA) at baseline and 12 months after PRP was performed. RESULTS: Thirty-eight eyes of 26 patients (15 female) with a mean age of 53.7 years (range 26 to 74 years) were recruited. No significant difference was found among all RNFL thickness parameters tested by GDx VCC software (p=0.952, 0.464 and 0.541 for temporal-superior-nasal-inferior-temporal (TSNIT) average, superior average, inferior average, respectively). The nerve fiber indicator (NFI) had a nonsignificant increase (p=0.354). The OCT results showed that the average RNFL thickness (360 degrees measurement) decreased nonsignificantly from 97.2 mm to 96.0 mm at 1 year post-PRP (p=0.469). There was no significant difference when separately analyzing all the peripapillary sectors (nasal superior, temporal superior, temporal, temporal inferior, nasal inferior and nasal thickness). CONCLUSION: Our results suggest that PRP, as performed in our study, does not cause significant changes in peripapillary RNFL in diabetic PDR patients after one year of follow-up.
  • article 7 Citação(ões) na Scopus
    Twenty-four-hour repeatability of diurnal intraocular pressure patterns in glaucomatous and ocular hypertensive individuals
    (2011) HATANAKA, Marcelo; BABIC, Mirko; SUSANNA JUNIOR, Remo
    OBJECTIVE: To verify the 24-hour repeatability of diurnal intraocular pressure patterns in glaucomatous and ocular hypertensive individuals. METHODS: A prospective analysis of 88 eyes from 88 ocular hypertensive or open-angle glaucoma patients was conducted on diurnal tension curves obtained by the same examiner on two consecutive days. The intraclass correlation coefficient test was used for statistical analysis. RESULTS: Eighty-eight eyes from 88 patients were analyzed. Fifty-seven patients (64.8%) were female. The mean age of all participants was 68.7 (SD 10.8, range 51-79) years. The intraclass correlation coefficient values for measurements at 8 AM, 11 AM, 2 PM, and 4 PM were 0.80, 0.82, 0.83, and 0.86, respectively (all intraclass correlation coefficient values, p<0.001). CONCLUSION: Diurnal intraocular pressure data collected on a single day characterize the diurnal intraocular pressure variability over 24 hours in primary open-angle glaucoma and ocular hypertensive patients.
  • article 3 Citação(ões) na Scopus
    Choroidal thickness variation in highly myopic eyes during the water drinking test
    (2016) GERMANO, Renato Antunes Schiave; HATANAKA, Marcelo; SUSANNA JUNIOR, Remo
    Purpose: To evaluate variations in choroidal thickness (CT) during the water drinking test (WDT) in emmetropic eyes (EE) and highly myopic eyes (ME) using spectral-domain optical coherence tomography (SD-OCT). Methods: Clinical trial performed at a tertiary care hospital comprising 30 randomly selected eyes. The WDT and SD-OCT macular scans were performed 10 and 45 min after water ingestion in 15 myopic and 15 EE of 15 healthy patients in each group. Primary study outcomes were average macular CT measured by SD-OCT and intraocular pressure (IOP) during the WDT. Results: The mean spherical equivalent refraction was 0.15 +/- 0.24 D in emmetropic and -7.1 +/- 1.75 D in ME (p < 0.001). No statistical differences between EE and ME were observed during the WDT response. EE had higher CT compared with ME at the fovea (361.4 +/- 55.4 vs 257.9 +/- 95.3; p < 0.001), 3 mm nasal to the fovea (158.0 +/- 71.8 vs 122.5 +/- 54.5; p = 0.047), and 3 mm temporally to the fovea (310.6 +/- 52.4 vs 247.6 +/- 90.1; p = 0.05). Regarding CT variation, significant differences in foveal CT at 10 min after water ingestion were observed in both EE and ME, with no statistically significant difference observed between groups. A moderate correlation between IOP peak during the WDT and CT was demonstrated in ME (r = 0.52; p = 0.04). Conclusions: No statistically significant differences in CT variation during the WDT were observed between EE and ME, indicating similar behavior of the choroidal bed during the WDT in both groups. Further, CT was thinner in highly ME, with CT variation unable to explain elevations in IOP observed during the WDT.
  • conferenceObject
  • article 0 Citação(ões) na Scopus
    The effect of panretinal photocoagulation on confocal laser scanning ophthalmoscopy and stereo photographic parameters of optic disk topography in patients with diabetic retinopathy
    (2019) AZEVEDO, Breno Marques da Silva; ARAUJO, Rafael Barbosa de; CIONGOLI, Marina R.; HATANAKA, Marcelo; PRETI, Rony Carlos; MONTEIRO, Mario Luiz Ribeiro; ZACHARIAS, Leandro Cabral
    Purpose: To determine the effect of panretinal photocoagulation on optic disk topographic parameters in non-glaucomatous patients with proliferative diabetic retinopathy. Methods: This was a prospective, single-center, observational study. Thirty-eight eyes of 26 patients with diabetes underwent panretinal photocoagulation for proliferative diabetic retinopathy. Stereoscopic disk photographs and optic nerve head parameters were evaluated using the Zeiss fundus camera and the confocal scanning laser ophthalmoscope (Heidelberg Retinal Tomograph), respectively, at baseline and 12 months after the completion of panretinal photocoagulation. Results: Thirty-eight eyes of 26 patients (15 female) with a mean age of 53.7 (range 26-74) years were recruited. No significant difference was found between the stereo photography determined mean horizontal and vertical cup-to-disk ratio before and after panretinal photocoagulation treatment (p=0.461 and 0.839, respectively). The global values of the optic nerve head parameters analyzed with the HRT3 showed no significant change from baseline to 12 months, including the disk area, cup area, rim area, cup volume, rim volume, cup-to-disk area ratio, linear cup-to-disk ratio, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness, and cross-sectional area. Conclusion: Our results suggest that panretinal photocoagulation does not cause morphological optic disk changes in patients with diabetic proliferative retinopathy after 1 year of follow-up.
  • article 3 Citação(ões) na Scopus
    The role of pattern-reversal electroretinography in the diagnosis of glaucoma
    (2014) KREUZ, Andre Carvalho; OYAMADA, Maria Kiyoko; HATANAKA, Marcelo; MONTEIRO, Mario Luiz Ribeiro
    Pattern electroretinography is used to assess the function of the inner retinal layers, particularly the retinal ganglion cell layer, using a reversing checkerboard or grating pattern that maintains a constant overall mean luminance over time. A normal transient response comprises a positive component of the wave (P50) followed by a longer negative component of the wave (N95). Glaucomatous optic neuropathy causes progressive loss of retinal ganglion cells, potentially detectable as abnormalities on examination, particularly in the N95 component. Therefore, pattern electroretinography may be useful in the diagnosis and evaluation of glaucoma. The present article is an updated review of published data regarding the use of pattern electroretinography for the detection of glaucoma-induced retinal changes.