CESAR AUGUSTO MARTINS PEREIRA

(Fonte: Lattes)
Índice h a partir de 2011
8
Projetos de Pesquisa
Unidades Organizacionais
Departamento de Ortopediae Traumatologia, Faculdade de Medicina
LIM/41 - Laboratório de Investigação Médica do Sistema Músculoesquelético, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • article 3 Citação(ões) na Scopus
    Simple suture and anchor in rabbit hips
    (2012) GARCIA FILHO, Fernando Cal; GUARNIERO, Roberto; GODOY JR., Rui Maciel de; PEREIRA, Cesar Augusto Martins; MATOS, Marcos Almeida; GARCIA, Lucas Cortizo
    Objective: Using biomechanical studies, this research aims to compare hip capsulorrhaphy in rabbits, carried out with two different techniques: capsulorrhaphy with simple sutures and with anchors. Method: Thirteen New Zealand Albino (Oryctolaguscuniculus) male rabbits, twenty-six hip joints, were used. First, a pilot project was performed with three rabbits (six hip joints). This experiment consisted of ten rabbits divided into two groups: group 1 underwent capsulorrhaphy on both right and left hips with simple suture using polyglycolic acid absorbable thread, and group 2 underwent capsulorrhaphy with titanium anchors. After a four-week postoperative period, the animals were euthanized and the hip joints were frozen. On the same day of the biomechanical studies, after the hip joints were previously unfrozen, the following parameters were evaluated: rigidity, maximum force, maximum deformity and energy. Results: There was no relevant statistical difference in rigidity, maximum force, maximum deformity and energy between the simple suture and anchor groups. Conclusion: Through biomechanical analyses, using parameters of rigidity, maximum force, maximum deformity and energy, it has been shown that capsulorrhaphy with simple suture and with anchors has similar results in rabbit hip joints.
  • article 3 Citação(ões) na Scopus
    Método de ensaio biomecânico para análise da isometricidade na reconstrução do ligamento patelofemoral medial
    (2012) SADIGURSKY, David; GOBBI, Riccardo Gomes; PEREIRA, César Augusto Martins; PÉCORA, José Ricardo; CAMANHO, Gilberto Luis
    OBJECTIVE: To present a biomechanical device for evaluating medial patellofemoral ligament (MPFL) reconstruction and its isometricity. METHODS: An accessible biomechanical method that allowed application of physiological and non-physiological forces to the knee using a mechanical arm and application of weights and counterweights was developed, so as to enable many different evaluations and have a very accurate measurement system for distances between different structures, for analysis on experiments. This article describes the assembly of this system, and suggests some practical applications. Six cadaver knees were studied. The knees were prepared in a testing machine developed at the Biomechanics Laboratory of IOT-HCFMUSP, which allowed dynamic evaluation of patellar behavior, with quantification of patellar lateralization between 0° and 120°. The differences between the distances found with and without load applied to the patella were grouped according to the graft fixation angle (0°, 30°, 60° or 90°) and knee position (intact, damaged or reconstructed). RESULTS: There was a tendency for smaller lateral displacement to occur at fixation angles greater than 30 degrees of flexion, especially between the angles of 45° and 60° degrees of flexion, after the reconstruction. For the other angles, there was no statistical significance. CONCLUSION: The method developed is a useful tool for studies on the patellofemoral joint and the MPFL, and has a very accurate measurement system for distances between different structures. It can be used in institutions with fewer resources available.