RAMES MATTAR JUNIOR

(Fonte: Lattes)
Índice h a partir de 2011
11
Projetos de Pesquisa
Unidades Organizacionais
Departamento de Ortopediae Traumatologia, Faculdade de Medicina - Docente
LIM/41 - Laboratório de Investigação Médica do Sistema Músculoesquelético, Hospital das Clínicas, Faculdade de Medicina - Líder

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • article 63 Citação(ões) na Scopus
    Single, Superiorly Placed Reconstruction Plate Compared with Flexible Intramedullary Nailing for Midshaft Clavicular Fractures A Prospective, Randomized Controlled Trial
    (2015) ANDRADE-SILVA, Fernando Brandao; KOJIMA, Kodi Edson; JOERIS, Alexander; SILVA, Jorge Santos; MATTAR, Rames
    Background: Previous studies have shown good clinical results in patients with midshaft clavicular fractures treated with reconstruction plate fixation or elastic stable intramedullary nailing. The objective of this study was to compare these methods in terms of clinical and radiographic results. Methods: In this prospective, randomized controlled trial, fifty-nine patients with displaced midshaft clavicular fractures were randomly assigned to receive fixation with either a reconstruction plate (thirty-three patients), known as the plate group, or elastic stable intramedullary nailing (twenty-six patients), known as the nail group. The primary outcome was the six-month Disabilities of the Arm, Shoulder and Hand (DASH) score. The secondary outcomes included the Constant-Murley score, time to fracture union, residual shortening, level of postoperative pain, percentage of satisfied patients, and complication rates. Results: The mean six-month DASH score was 9.9 points in the plate group and 8.5 points in the nail group (p = 0.329). Similarly, there were no differences in the twelve-month DASH and Constant-Murley scores. Time to union was equivalent (p = 0.352) between the groups at 16.8 weeks for the plate group and 15.9 weeks for the nail group, whereas the residual shortening was 0.4 cm greater in the plate group (p = 0.032). The visual analog scale pain score and the satisfaction rate were similar between the groups. Implant-related pain was more frequent in the nail group (p = 0.035). There were no differences in terms of major complications. Conclusions: Reconstruction plates and elastic stable intramedullary nailing yielded similar functional results, time to union, level of postoperative pain, and patient satisfaction rates. Both methods were safe in terms of major complications.
  • article 16 Citação(ões) na Scopus
    INTERCOSTAL NERVE TRANSFER TO THE BICEPS MOTOR BRANCH IN COMPLETE TRAUMATIC BRACHIAL PLEXUS INJURIES
    (2015) BAIK, Alvaro; IAMAGUCHI, Raquel Bernardelli; SILVA, Gustavo Bersani; PAULOS, Renata Gregorio; KIYOHARA, Leandro Yoshinobu; SORRENTI, Luiz; MENEZES, Klicia de Oliveira Costa Riker Teles de; REZENDE, Marcelo Rosa de; WEI, Teng Hsiang; MATTAR JUNIOR, Rames
    The purpose of this report is to critically evaluate our results of two intercostal nerve transfers directly to the biceps motor branch in complete traumatic brachial plexus injuries. From January 2007 to November 2012, 19 patients were submitted to this type of surgery, but only 15 of them had a follow-up for >= 2 years and were included in this report. The mean interval from trauma to surgery was 6.88 months (ranging from 3 to 9 months). Two intercostals nerves were dissected and transferred directly to the biceps motor branch. The mean follow-up was 38.06 months (ranging from 24 to 62 months). Ten patients (66.6%) recovered an elbow flexion strength >= M3. Four of them (26.66%) recovered a stronger elbow flexion >= M4. One patient (6.25%) recovered an M2 elbow flexion and four patients (26.66%) did not regain any movement. We concluded that two intercostal nerve transfers to the biceps motor branch is a procedure with moderate results regarding elbow flexion recovery, but it is still one of the few options available in complete brachial plexus injuries, especially in five roots avulsion scenario. (C) 2015 Wiley Periodicals, Inc.
  • article 7 Citação(ões) na Scopus
    COMPARATIVE STUDY BETWEEN OSTEOSYNTHESIS IN CONVENTIONAL AND BIOABSORBABLE IMPLANTS IN ANKLE FRACTURES
    (2015) GAIARSA, Guilherme Pelosini; REIS, Paulo Roberto dos; MATTAR JUNIOR, Rames; SILVA, Jorge dos Santos; FERNANDEZ, Tlio Diniz
    Objective: To compare the functional results of ankle fractures treated with metallic and absorbable plates. Twenty patients were randomized into two groups (metallic and absorbable implant groups) and followed prospectively. In the immediate postoperative period, patients were immobilized with plaster casts for one week, which was replaced by a removable cast for another four weeks. Partial weight-bearing was allowed after three weeks, and full weight-bearing after six weeks. Functional recovery was similar in both groups. At six months, three patients in the metallic group complained of local pain, and had their implants removed. One patient in the absorbable group exhibited early dehiscence of the suture and underwent debridement and suturing with good evolution. The American Orthopaedic Foot and Ankle Society (AOFAS) score was similar between the two groups after six and nine months of follow-up. The absorbable implants showed clinical and functional results that were similar to those of metallic implants.