JOCIELLE SANTOS DE MIRANDA

(Fonte: Lattes)
Índice h a partir de 2011
7
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/08 - Laboratório de Anestesiologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • conferenceObject
    Bilateral Inguinal Hernia Repair and Male Fertility: A Randomized Clinical Trial Comparing Lichtenstein vs Laparoscopic Transabdominal Preperitoneal
    (2022) DAMOUS, Sergio H. B.; DAMOUS, Luciana L.; BORGES, Victor A.; FONTELLA, Amanda K.; MIRANDA, Jocielle S.; KOIKE, Marcia K.; SAITO, Osmar C.; BIROLINI, Claudio A. V.; UTIYAMA, Edivaldo M.
  • article 0 Citação(ões) na Scopus
    Bilateral inguinal hernia repair and male fertility: a randomized clinical trial comparing Lichtenstein versus laparoscopic transabdominal preperitoneal (TAPP) technique
    (2023) DAMOUS, Sergio Henrique Bastos; DAMOUS, Luciana Lamarao; BORGES, Victor Andre; FONTELLA, Amanda Karsburg; MIRANDA, Jocielle dos Santos; KOIKE, Marcia Kiyomi; SAITO, Osmar Cassio; BIROLINI, Claudio Augusto Vianna; UTIYAMA, Edivaldo Massazo
    Background The effects of hernia repair on testicular function remain uncertain, regardless of the technique used. Studies that analyze testicular volume and flow after hernia repair or hormonal measurements are scarce and show contradictory results. This study aimed to evaluate the impact of bilateral inguinal hernia repair on male fertility in surgical patients in whom the Lichtenstein and laparoscopic transabdominal preperitoneal (TAPP) techniques were used.Methods A randomized clinical trial comparing open (Lichtenstein) versus laparoscopic (TAPP) hernia repair using polypropylene mesh was performed in 48 adult patients (20 to 60 years old) with primary bilateral inguinal hernia. Patients were evaluated preoperatively and 90 and 180 postoperative (PO) days. Sex hormones (Testosterone, FSH, LH and SHGB) analysis, testicular ultrasonography, semen quality sexual activity changes and quality of life (QoL) were performed. Postoperative pain was evaluated using the visual analog scale (VAS).Results Thirty-seven patients with aged of 44 +/- 11 years were included, 19 operated on Lichtenstein and 18 operated on TAPP. The surgical time was similar between techniques. The pain was greater in the Lichtenstein group on the 7th PO day. The biochemical and hormonal analyses, testicular ultrasonography (Doppler, testicular volume, and morphological findings) and sperm quality were similar between groups. However, the sperm morphology was better in the Lichtenstein group after 180 days (p < 0.05 vs. preoperative) and two patients who underwent Lichtenstein hernia repair had oligospermia after 180 days. The QoL evaluation showed a significant improvement after surgery in the following domains: physical function, role emotional, bodily pain and general health (p < 0.05). On comparison of Lichtenstein vs. TAPP none of the domains showed statistically significant differences. No patient reported sexual changes.Conclusion Bilateral inguinal hernia repair with polypropylene mesh, whether using Lichtenstein or TAPP, does not impair male fertility in terms of long-term outcomes.Trial registration: Approved by the Ethics Committee for the Analysis of Research Projects (CAPPesq) of the HC/FMUSP, Number 2.974.457, in June 2015, Registered on Plataforma Brasil in October 2015 under Protocol 45535015.4.0000.0068. Registered on Clinicaltrials.gov, NCT 05799742. Enrollment of the first subject in January 2016.
  • article 1 Citação(ões) na Scopus
    Microbiology of chronic mesh infection
    (2023) BIROLINI, C.; FARO JUNIOR, M. P.; TERHOCH, C. B.; MIRANDA, J. S. de; TANAKA, E. Y.; UTIYAMA, E. M.
    PurposeMesh infection following hernia repair is one of the most dreaded complications of hernia surgery. Mesh sinus, infected seromas, mesh extrusion, and mesh-related enteric fistulas are common complications associated with synthetic mesh. This study aimed to review the microbiota of mesh infection in 100 patients submitted to mesh explantation.MethodsWe reviewed the charts of patients presenting with a history of mesh infection lasting or arising six months or more after mesh placement. All patients who submitted to abdominal wall repair with complete removal of an infected mesh and presenting a positive culture were included. The microbiology analysis was based on positive cultures obtained from the fluids and tissues surrounding the mesh or positive cultures of the mesh. Microorganisms were divided into gram-positive or gram-negative, aerobic or anaerobic, and fungi.ResultsPure aerobic gram-positive cultures were encountered in 50% of the patients, followed by a combination of aerobic gram-positive/gram-negative (8%) and pure gram-negative cultures (6%). Anaerobes were recovered from 31% of patients. Fungi were recovered from 6%. Staphylococcus aureus was identified in 64% of cultures, with methicillin-resistant Staphylococcus aureus present in 42% and methicillin-sensitive Staphylococcus aureus in 22%. Among aerobic gram-negative infections, six (17%) were caused by multi-resistant bacteria, including Pseudomonas aeruginosa, Proteus mirabilis, Acinetobacter baumanii, Klebsiella pneumoniae complex, and Enterobacter cloacae complex.ConclusionStaphylococcus aureus plays a significant role in the pathogenesis of synthetic mesh infection. Staphylococcus aureus, isolated in 64% of cultures, accounted for most single bacterial infections and was the prevalent germ in mesh sinus and infected seromas. Gram-negative infection occurred in 35%. Anaerobes occurred in 31%, commonly encountered in polymicrobial infections. Most fungi cultures happened in patients with enteric fistulas.