LEONARDO PROVETTI CUNHA

(Fonte: Lattes)
Índice h a partir de 2011
7
Projetos de Pesquisa
Unidades Organizacionais
LIM/33 - Laboratório de Oftalmologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 9 de 9
  • article 20 Citação(ões) na Scopus
    Non-Mydriatic Fundus Retinography in Screening for Diabetic Retinopathy: Agreement Between Family Physicians, General Ophthalmologists, and a Retinal Specialist
    (2018) CUNHA, Leonardo Provetti; FIGUEIREDO, Evelyn Alvernaz; ARAUJO, Henrique Pereira; COSTA-CUNHA, Luciana Virginia Ferreira; COSTA, Carolina Ferreira; COSTA NETO, Jose de Melo; MATOS, Aline Mota Freitas; OLIVEIRA, Marise Machado de; BASTOS, Marcus Gomes; MONTEIRO, Mario Luiz Ribeiro
    Purpose: To determine the level of agreement between trained family physicians (FPs), general ophthalmologists (GOs), and a retinal specialist (RS) in the assessment of non-mydriatic fundus retinography in screening for diabetic retinopathy (DR) in the primary health-care setting. Methods: 200 Diabetic patients were submitted to two-field non-mydriatic digital fundus camera. The images were examined by four trained FPs, two GOs, and one RS with regard to the diagnosis and severity of DR and the diagnosis of macular edema. The RS served as gold standard. Reliability and accuracy were determined with the kappa test and diagnostic measures. Results: A total of 397 eyes of 200 patients were included. The mean age was 55.1 (+/- 11.7) years, and 182 (91%) had type 2 diabetes. The mean levels of serum glucose and glycosylated hemoglobin A1c were 195.6 (+/- 87.3) mg/dL and 8.9% (+/- 2.1), respectively. DR was diagnosed in 166 eyes by the RS and in 114 and 182 eyes by GO(1) and GO(2), respectively. For severity, DR was graded as proliferative in 8 eyes by the RS vs. 15 and 9 eyes by GO(1) and GO(2), respectively. The agreement between the RS and the GOs was substantial for both DR diagnosis (GO(1) k = 0.65; GO(2) k = 0.74) and severity (GO(1) k = 0.60; GO(2) k = 0.71), and fair or moderate for macular edema (GO(1) k = 0.27; GO(2) k = 0.43). FP1, FP2, FP3, and FP4 diagnosed DR in 108, 119, 163, and 117 eyes, respectively. The agreement between the RS and the FPs with regard to DR diagnosis was substantial (FP2 k = 0.69; FP3 k = 0.73; FP4 k = 0.71) or moderate (FP1 k = 0.56). As for DR severity, the agreement between the FPs and the RS was substantial (FP2 k = 0.66; FP3 k = 069; FP4 k = 0.64) or moderate (FP1 k = 0.51). Agreement between the FPs and the RS with regard to macular edema was fair (FP1 k = 0.33; FP2 k = 0.39; FP3 k = 0.37) or moderate (FP4 k = 0.51). Conclusion: Non-mydriatic fundus retinography was shown to be useful in DR screening in the primary health-care setting. FPs made assessments with good levels of agreement with an RS. Non-mydriatic fundus retinography associated with appropriate general physicians training is essential for the DR screening.
  • article 2 Citação(ões) na Scopus
    Ultrastructural changes detected using swept-source optical coherence tomography in severe vitreopapillary traction: a case report
    (2019) CUNHA, Leonardo Provetti; COSTA-CUNHA, Luciana Virginia Ferreira; COSTA, Carolina Ferreira; MONTEIRO, Mario Luiz Ribeiro
    Vitreopapillaiy traction is an uncommon condition characterized by strong adhesion and the traction of the posterior hyaloid onto the optic disc and peripapillary retina, leading to optic disc elevation and visual loss. An 85-year-old man presented with a 6-month history of slow, progressive visual loss in the left eye along with optic disc edema. Swept-source optical coherence tomography B-scans revealed circumpapillaiy anterior-posterior persistent traction of dense vitreous strands onto the optic disc. Visual field examination demonstrated mild, generalized, diffuse sensitivity loss and blind-spot enlargement. A 25-gauge posterior vitrectomy was performed with posterior hyaloid separation from the optic disc, resulting in significant anatomical and visual improvement. In conclusion, swept-source optical coherence tomography aids in understanding the mechanism underlying visual loss in vitreopapillary traction. Moreover, posterior vitrectomy can effectively promote anatomical and visual improvements in these cases.
  • article 3 Citação(ões) na Scopus
    Safety and cost-effectiveness of single-use endolaser probe reprocessing in vitreoretinal surgery
    (2021) ZACHARIAS, Leandro Cabral; CONCI, Livia da Silva; MEGNIS, Bianca Partezani; FALABRETTI, Janaina Guerra; RODRIGUES NETO, Taurino dos Santos; SILVA NETO, Epitacio Dias da; PRETI, Rony Carlos; CUNHA, Leonardo Proveti; MONTEIRO, Mario Luiz Ribeiro
    BackgroundEndolaser probes have been designed and sold for single-use only. However, in Brazil, they are not included in the list of single-use medical products that are prohibited from being reprocessed and could potentially be reused if safety requirements are accomplished. Therefore, this study aimed to determine and compare the quality, safety and costs of reprocessed versus original single-use endolaser probes of a specific brand and model.MethodsThe study, conducted at a university hospital in Sao Paulo, Brazil, was divided in two phases. The first one tested the feasibility, sterility and physical integrity of ten reprocessed laser probes. In the second phase, all vitrectomy procedures using endolaser probes (reprocessed and original ones) from August 2017 to October 2019 were evaluated. The operated cases were followed for any signs of infection and number of defective probes for each group were counted. The cost of acquiring a new probe and for all reprocessing stages were evaluated and quantified in US dollars($).ResultsMicrobiologic, residual ethilen oxide and microscopic evaluation of integrity of reprocessed laser probes were all within acceptable range. The second phase of this study included 590 endolaser probes, of which 375 were original and 215 were reprocessed. Functionality rates differed significantly between groups. Among the original probes, 373 (99.47%) were functioning and 2 (0.53%) were non-functioning. Among the reprocessed ones, 201 (93.5%) were functioning and 14 (6.5%) were non-functioning (p<.001). The average cost of one reprocessing was $3.00, and the average cost of an original probe was $150.00. Considering the loss rates, potential savings were $147.60 for each once-reprocessed probe. The frequency of infectious endophthalmitis was null in both groups.ConclusionsOur study showed that a single cycle endolaser probe reprocessing was safe and efficient, not associated with increase in endophthalmitis rate and proved to be significantly cost-effective, even considering a greater malfunction rate when compared to the original devices.
  • article 3 Citação(ões) na Scopus
    Prevalence of Focal Inner, Middle, and Combined Retinal Thinning in Diabetic Patients and Its Relationship With Systemic and Ocular Parameters
    (2021) PRETI, Rony Carlos; IOVINO, Claudio; ABALEM, Maria Fernanda; GARCIA, Rafael; SANTOS, Helen Nazareth Veloso dos; SAKUNO, Gustavo; AU, Adrian; CUNHA, Leonardo Provetti; ZACHARIAS, Leandro Cabral; MONTEIRO, Mario Luiz Ribeiro; SADDA, Srinivas Reddy; SARRAF, David
    Purpose: To determine the prevalence of focal inner, middle, and combined inner/middle retinal thinning (FIRT, FMRT, and FCRT, respectively) in different stages of diabetic retinopathy (DR) without diabetic macular edema and to assess the relationship between such findings with ocular and systemic parameters. Methods: This was a cross-sectional, comparative study comprising healthy participants and diabetic patients with different stages of DR. Forty-nine horizontal macular B-scans from the selected eye were obtained using spectral-domain optical coherence tomography (SD-OCT) and analyzed for the presence of FIRT, FMRT, or FCRT and any relationship with systemic and ocular parameters. Focal retinal thinning (FRT) was subjectively defined as any evidence of inner and/or middle retinal thinning. Results: A total of 190 participants (52 healthy participants and 138 diabetic patients) were included. A higher prevalence of FRT was observed in eyes with advanced DR versus healthy eyes and versus diabetic eyes with no DR or mild DR. FIRT and FCRT were significantly greater in eyes with proliferative DR treated with pan-retinal photocoagulation, and FMRT was significantly more common in eyes with severe nonproliferative DR. FRT was significantly more common in patients with coronary artery disease and was positively correlated with diabetes duration, serum creatinine, and glycosylated hemoglobin and negatively correlated with age, estimated glomerular filtration rate, and visual acuity. Conclusions: FRT occurs in all stages of DR and is increasingly prevalent with increasing severity of DR. Translational Relevance: OCT identification of FRT may provide a surrogate biomarker of retinal and systemic disease in diabetic patients.
  • article 10 Citação(ões) na Scopus
    Multifocal pattern electroretinography for the detection of neural loss in eyes with permanent temporal hemianopia or quadrantanopia from chiasmal compression
    (2012) MONTEIRO, Mario Luiz Ribeiro; HOKAZONO, Kenzo; CUNHA, Leonardo Provetti; OYAMADA, Maria Kiyoko
    Aims To evaluate the ability of multifocal transient pattern electroretinography (mfPERG) to detect neural loss and assess the relationship between mfPERG and visual-field (VF) loss in eyes with chiasmal compression. Methods 23 eyes from 23 patients with temporal VF defects and band atrophy of the optic nerve and 21 controls underwent standard automated perimetry and mfPERG using a stimulus pattern of 19 rectangles, each consisting of 12 squares. The response was determined for the central rectangle, for the nasal and temporal hemifields (eight rectangles each) and for each quadrant (three rectangles) in both patients and controls. Comparisons were made using variance analysis. Correlations between VF and mfPERG measurements were verified by linear regression analysis. Results Mean +/- SD mfPERG amplitudes from the temporal hemifield (0.50 +/- 0.17 and 0.62 +/- 0.32) and temporal quadrants (superior 0.42 +/- 0.21 and 0.52 +/- 0.35, inferior 0.51 +/- 0.23 and 0.74 +/- 0.40) were significantly lower in eyes with band atrophy than in controls (0.78 +/- 0.24, 0.89 +/- 0.28, 0.73 +/- 60.26, 0.96 +/- 0.36, 0.79 +/- 0.26 and 0.91 +/- 0.31, respectively). No significant difference was observed in nasal hemifield measurements. Significant correlations (0.36-0.73) were found between VF relative sensitivity and mfPERG amplitude in different VF sectors. Conclusions mfPERG amplitude measurements clearly differentiate eyes with temporal VF defect from controls. The good correlation between mfPERG amplitudes and the severity of VF defect suggests that mfPERG may be used as an indicator of ganglion cell dysfunction.
  • article 0 Citação(ões) na Scopus
    Optical coherence tomography detection of retinal neural loss in patients with tuberous sclerosis
    (2024) DIAS, Paula Basso; LINHARES, Anna Carolina Badotti; URZEDO, Ana Barbara Dias Lopes; PRETI, Rony Carlos; ZACHARIAS, Leandro Cabral; CUNHA, Leonardo Provetti; MONTEIRO, Mario Luiz Ribeiro; HOKAZONO, Kenzo
    PurposeTuberous Sclerosis (TS) is a rare, multisystem genetic disease caused by mutations in the TSC1 and TSC2 genes, leading to abnormalities in cell differentiation and proliferation. This study aimed to evaluate the neural integrity of individuals with TS by using Optical Coherence Tomography (OCT) to examine the peripapillary retinal nerve fiber layer (RNFL) thickness and the macular thickness in patients with TS and to compare with healthy controls.MethodsPeripapillary and macular OCT scans (Optopol Revo NX SD OCT) were performed on 41 eyes from 22 TS patients, divided into two groups based on the presence of retinal hamartomas, and compared to 20 eyes from a control group. The average peripapillary RNFL thickness was measured for each quadrant. The macular total thickness and ganglion cell layer (GCL) + inner plexiform layer (IPL) thickness were measured based on the Early Treatment Diabetic Retinopathy Study (ETDRS) map. All measurements were then compared between the groups and controls.ResultsThe TS group showed significantly reduced RNFL thickness and macular thickness when compared to the control group. Specifically, patients with retinal hamartomas exhibited an even more pronounced thinning of both RNFL and macular thickness.ConclusionsThese findings suggest that TS patients undergo significant changes in retinal neurodevelopment and experience axonal loss. This finding may have significant prognostic utility regarding central nervous system degeneration in TS, particularly among patients with retinal hamartomas. OCT may serve as a valuable tool for assessing axonal structural abnormalities in TS patients.Trial Registration Number: Not applicable.ConclusionsThese findings suggest that TS patients undergo significant changes in retinal neurodevelopment and experience axonal loss. This finding may have significant prognostic utility regarding central nervous system degeneration in TS, particularly among patients with retinal hamartomas. OCT may serve as a valuable tool for assessing axonal structural abnormalities in TS patients.Trial Registration Number: Not applicable.
  • article 0 Citação(ões) na Scopus
    Correlation between retinal sensitivity assessed by microperimetry and structural abnormalities on optical coherence tomography after successful epiretinal membrane surgery
    (2024) MATOS, Aline Mota Freitas; DEFINA, Raphael Lucas Sampaio; COSTA-CUNHA, Luciana Virginia Ferreira; ZACHARIAS, Leandro Cabral; PRETI, Rony Carlos; MONTEIRO, Mario Luiz Ribeiro; CUNHA, Leonardo Provetti
    BackgroundTo verify the correlation between retinal sensitivity (RS) assessed by the microperimetry (MP) and optical coherence tomography (OCT) parameters measured in eyes submitted to pars-plana vitrectomy (PPV) for idiopathic epiretinal membrane (ERM) treatment.Methods43 patients underwent PPV. Best-corrected visual acuity (BCVA) and OCT imaging were acquired preoperatively and 6 months after surgery. The RS values were recorded 6 months after the surgery. Total macular thickness (TMT) measurements and OCT-evaluated structural findings were also analyzed. The MP examination tested 44 points, with direct topographic correspondence with the OCT-ETDRS map. Correlations between BCVA, RS, and OCT parameters were assessed.ResultsTMT measurements in patients were significantly thicker preoperatively and reduced after surgery. All patients demonstrated BCVA improvements after surgery. The RS parameters after surgery were significantly lower in patients. For OCT structural analyses, patients with lower RS at the fovea correlated with the preexisting disorganization of retinal inner layers (DRIL). In addition, lower RS values were associated with DRIL, outer retinal changes (ORC), and intraretinal microcysts after surgery.ConclusionsThe RS values after surgery were significantly lower when compared to controls. The DRIL presence before and after surgery, and microcysts and ORC after surgery were related to worse visual outcomes.
  • article 0 Citação(ões) na Scopus
    Morning glory disc anomaly associated with large facial infantile hemangioma as the presenting signs of PHACE syndrome
    (2020) HOKAZONO, Kenzo; OKUYAMA, Vinicius Tadashi; CUNHA, Leonardo Provetti; MONTEIRO, Mario Luiz Ribeiro
    Infantile hemangioma, the most common benign tumor in infancy, is usually an isolated condition occurring in many different locations in the body. However, large infantile hemangioma may be associated with other systemic malformations, including central nervous system, cerebrovascular, cardiac, and ophthalmology abnormalities, a condition termed PHACE syndrome. In this paper, we describe a case of PHACE syndrome that was presented with the unique association of a large facial infantile hemangioma and morning glory anomaly.
  • article 2 Citação(ões) na Scopus
    Optic coherence tomography features of subretinal vitreous substitutes
    (2020) ZACHARIAS, Leandro Cabral; SILVA NETO, Epitacio Dias da; RODRIGUES NETO, Taurino dos Santos; CARVALHO JUNIOR, Jose Ronaldo Lima de; PRETI, Rony Carlos; CUNHA, Leonardo Provetti; TANAKA, Tatiana; MONTEIRO, Mario Luiz Ribeiro
    BackgroundTo draw comparisons between spectral domain optic coherence tomography (SD-OCT) features of subretinal silicon oil (SO), perfluoro-n-octane (PFO) or C3F8 gas.MethodsCases diagnosed with retained subretinal vitreous substitutes (VS) were retrospectively selected. Demographic data were collected and OCT features were analyzed.ResultsIn the 13 cases with subretinal PFO, hyper-reflectivity under the bubble was noted in 8 eyes (61.5%); choroidal shadow at the borders of the bubble in 11 eyes (84.6%); hyper-reflective halo around the bubble in 5 eyes (38.4%) and a hyper-reflective apical dot in 8 eyes (61.5%).The two cases with multiple PFO bubbles had complete septum dividing the bubbles. The one case with subretinal SO had hyper reflectivity under the bubble; no choroidal shadow at the edge of the bubble; hyper-reflective halo was noted around the bubble and the apical hyper-reflective dot was present; there was no complete septum dividing multiple bubbles. The single case with subretinal C3F8 had some bubbles with totally round base, incomplete septum, hyper reflectivity under the bubble, choroidal shadow at the edge of the bubble, a hyper-reflective halo and an apical dot.ConclusionDifferent subretinal VS share similar SD-OCT characteristics. Round base bubbles are only observed with subretinal C3F8 gas, while incomplete septum are related to retained subretinal SO or gas.