LEONARDO PROVETTI CUNHA

(Fonte: Lattes)
Índice h a partir de 2011
7
Projetos de Pesquisa
Unidades Organizacionais
LIM/33 - Laboratório de Oftalmologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 6 de 6
  • article 0 Citação(ões) na Scopus
    Relationship between automated choroidal thickness measurements and retinal sensitivity using microperimetry in patients with myopia and different stages of myopic maculopathy
    (2024) SILVA, Fillipe de Biaggi Borges da; SILVA, Luis Claudio Pimentel; CUNHA, Leonardo Provetti; ZACHARIAS, Leandro Cabral; NAVAJAS, Eduardo V.; MONTEIRO, Mario L. R.; PRETI, Rony C.
    Purpose To assess the relationship between macular choroidal thickness (CT) measurements and retinal sensitivity (RS) in eyes with myopia and different stages of myopic maculopathy. Methods A masked, cross-sectional, and consecutive study involving patients with emmetropia/myopia (control group) and high myopia (HM) eyes. Automated choroidal thickness (CT) and manual outer retinal layer (ORL) thickness were acquired using swept-source optical coherence tomography, while retinal sensitivity (RS) assessed by microperimetry (MP3) in all regions of the macular Early Treatment Diabetic Retinopathy Study (ETDRS) grid. Comparisons were made between groups, and correlations were performed among these measurements, demographic and ocular parameters and myopic maculopathy classification. Results A total of 37 (74 eyes) patients were included in the study. The mean age was 39 +/- 13 years, and 28 patients (76%) were female. HM eyes exhibited inferior best-corrected visual acuity and a more advanced myopic maculopathy classification compared to the control group. The mean macular CT were 255 and 179 mu m in the control and HM eyes (P < 0.001), respectively. In the HM eyes, superior ETDRS region presented the greatest values. Mean RS in control and HM groups was 28 and 24 dB (P = 0.001), respectively. Inner temporal followed by superior, were the regions of higher RS. Mean ORL thickness was 83 and 79 mu m (P < 0.001), in the control and HM groups, respectively. The inner temporal ETDRS region presented the thickest measure. CT correlated significantly with RS (r = 0.41, P < 0.001) and ORL thickness, (r = 0.58, P < 0.001), which also correlated with RS (r = 0.40, P < 0.001). Spherical equivalent, axial length and myopic maculopathy stage were the parameters that most correlated with CT, RS and ORL thickness. For every 100 mu m increase in thickening of CT there was an average increase of 3.4 mu m in ORL thickness and 2.7 dB in RS. Myopic maculopathy classification demonstrated influence only with CT. Conclusion Myopia degree is related to ORL and choroidal thinning and deterioration of retinal sensitivity in some ETDRS regions of the macula. Choroidal thinning is associated to with a decline of retinal sensitivity, thinning of ORL, and worsening of myopic maculopathy classification, so new treatments are necessary to prevent myopia progression.
  • article 3 Citação(ões) na Scopus
    Safety and cost-effectiveness of single-use endolaser probe reprocessing in vitreoretinal surgery
    (2021) ZACHARIAS, Leandro Cabral; CONCI, Livia da Silva; MEGNIS, Bianca Partezani; FALABRETTI, Janaina Guerra; RODRIGUES NETO, Taurino dos Santos; SILVA NETO, Epitacio Dias da; PRETI, Rony Carlos; CUNHA, Leonardo Proveti; MONTEIRO, Mario Luiz Ribeiro
    BackgroundEndolaser probes have been designed and sold for single-use only. However, in Brazil, they are not included in the list of single-use medical products that are prohibited from being reprocessed and could potentially be reused if safety requirements are accomplished. Therefore, this study aimed to determine and compare the quality, safety and costs of reprocessed versus original single-use endolaser probes of a specific brand and model.MethodsThe study, conducted at a university hospital in Sao Paulo, Brazil, was divided in two phases. The first one tested the feasibility, sterility and physical integrity of ten reprocessed laser probes. In the second phase, all vitrectomy procedures using endolaser probes (reprocessed and original ones) from August 2017 to October 2019 were evaluated. The operated cases were followed for any signs of infection and number of defective probes for each group were counted. The cost of acquiring a new probe and for all reprocessing stages were evaluated and quantified in US dollars($).ResultsMicrobiologic, residual ethilen oxide and microscopic evaluation of integrity of reprocessed laser probes were all within acceptable range. The second phase of this study included 590 endolaser probes, of which 375 were original and 215 were reprocessed. Functionality rates differed significantly between groups. Among the original probes, 373 (99.47%) were functioning and 2 (0.53%) were non-functioning. Among the reprocessed ones, 201 (93.5%) were functioning and 14 (6.5%) were non-functioning (p<.001). The average cost of one reprocessing was $3.00, and the average cost of an original probe was $150.00. Considering the loss rates, potential savings were $147.60 for each once-reprocessed probe. The frequency of infectious endophthalmitis was null in both groups.ConclusionsOur study showed that a single cycle endolaser probe reprocessing was safe and efficient, not associated with increase in endophthalmitis rate and proved to be significantly cost-effective, even considering a greater malfunction rate when compared to the original devices.
  • article 0 Citação(ões) na Scopus
    Optical coherence tomography detection of retinal neural loss in patients with tuberous sclerosis
    (2024) DIAS, Paula Basso; LINHARES, Anna Carolina Badotti; URZEDO, Ana Barbara Dias Lopes; PRETI, Rony Carlos; ZACHARIAS, Leandro Cabral; CUNHA, Leonardo Provetti; MONTEIRO, Mario Luiz Ribeiro; HOKAZONO, Kenzo
    PurposeTuberous Sclerosis (TS) is a rare, multisystem genetic disease caused by mutations in the TSC1 and TSC2 genes, leading to abnormalities in cell differentiation and proliferation. This study aimed to evaluate the neural integrity of individuals with TS by using Optical Coherence Tomography (OCT) to examine the peripapillary retinal nerve fiber layer (RNFL) thickness and the macular thickness in patients with TS and to compare with healthy controls.MethodsPeripapillary and macular OCT scans (Optopol Revo NX SD OCT) were performed on 41 eyes from 22 TS patients, divided into two groups based on the presence of retinal hamartomas, and compared to 20 eyes from a control group. The average peripapillary RNFL thickness was measured for each quadrant. The macular total thickness and ganglion cell layer (GCL) + inner plexiform layer (IPL) thickness were measured based on the Early Treatment Diabetic Retinopathy Study (ETDRS) map. All measurements were then compared between the groups and controls.ResultsThe TS group showed significantly reduced RNFL thickness and macular thickness when compared to the control group. Specifically, patients with retinal hamartomas exhibited an even more pronounced thinning of both RNFL and macular thickness.ConclusionsThese findings suggest that TS patients undergo significant changes in retinal neurodevelopment and experience axonal loss. This finding may have significant prognostic utility regarding central nervous system degeneration in TS, particularly among patients with retinal hamartomas. OCT may serve as a valuable tool for assessing axonal structural abnormalities in TS patients.Trial Registration Number: Not applicable.ConclusionsThese findings suggest that TS patients undergo significant changes in retinal neurodevelopment and experience axonal loss. This finding may have significant prognostic utility regarding central nervous system degeneration in TS, particularly among patients with retinal hamartomas. OCT may serve as a valuable tool for assessing axonal structural abnormalities in TS patients.Trial Registration Number: Not applicable.
  • article 0 Citação(ões) na Scopus
    Correlation between retinal sensitivity assessed by microperimetry and structural abnormalities on optical coherence tomography after successful epiretinal membrane surgery
    (2024) MATOS, Aline Mota Freitas; DEFINA, Raphael Lucas Sampaio; COSTA-CUNHA, Luciana Virginia Ferreira; ZACHARIAS, Leandro Cabral; PRETI, Rony Carlos; MONTEIRO, Mario Luiz Ribeiro; CUNHA, Leonardo Provetti
    BackgroundTo verify the correlation between retinal sensitivity (RS) assessed by the microperimetry (MP) and optical coherence tomography (OCT) parameters measured in eyes submitted to pars-plana vitrectomy (PPV) for idiopathic epiretinal membrane (ERM) treatment.Methods43 patients underwent PPV. Best-corrected visual acuity (BCVA) and OCT imaging were acquired preoperatively and 6 months after surgery. The RS values were recorded 6 months after the surgery. Total macular thickness (TMT) measurements and OCT-evaluated structural findings were also analyzed. The MP examination tested 44 points, with direct topographic correspondence with the OCT-ETDRS map. Correlations between BCVA, RS, and OCT parameters were assessed.ResultsTMT measurements in patients were significantly thicker preoperatively and reduced after surgery. All patients demonstrated BCVA improvements after surgery. The RS parameters after surgery were significantly lower in patients. For OCT structural analyses, patients with lower RS at the fovea correlated with the preexisting disorganization of retinal inner layers (DRIL). In addition, lower RS values were associated with DRIL, outer retinal changes (ORC), and intraretinal microcysts after surgery.ConclusionsThe RS values after surgery were significantly lower when compared to controls. The DRIL presence before and after surgery, and microcysts and ORC after surgery were related to worse visual outcomes.
  • article 2 Citação(ões) na Scopus
    Optic coherence tomography features of subretinal vitreous substitutes
    (2020) ZACHARIAS, Leandro Cabral; SILVA NETO, Epitacio Dias da; RODRIGUES NETO, Taurino dos Santos; CARVALHO JUNIOR, Jose Ronaldo Lima de; PRETI, Rony Carlos; CUNHA, Leonardo Provetti; TANAKA, Tatiana; MONTEIRO, Mario Luiz Ribeiro
    BackgroundTo draw comparisons between spectral domain optic coherence tomography (SD-OCT) features of subretinal silicon oil (SO), perfluoro-n-octane (PFO) or C3F8 gas.MethodsCases diagnosed with retained subretinal vitreous substitutes (VS) were retrospectively selected. Demographic data were collected and OCT features were analyzed.ResultsIn the 13 cases with subretinal PFO, hyper-reflectivity under the bubble was noted in 8 eyes (61.5%); choroidal shadow at the borders of the bubble in 11 eyes (84.6%); hyper-reflective halo around the bubble in 5 eyes (38.4%) and a hyper-reflective apical dot in 8 eyes (61.5%).The two cases with multiple PFO bubbles had complete septum dividing the bubbles. The one case with subretinal SO had hyper reflectivity under the bubble; no choroidal shadow at the edge of the bubble; hyper-reflective halo was noted around the bubble and the apical hyper-reflective dot was present; there was no complete septum dividing multiple bubbles. The single case with subretinal C3F8 had some bubbles with totally round base, incomplete septum, hyper reflectivity under the bubble, choroidal shadow at the edge of the bubble, a hyper-reflective halo and an apical dot.ConclusionDifferent subretinal VS share similar SD-OCT characteristics. Round base bubbles are only observed with subretinal C3F8 gas, while incomplete septum are related to retained subretinal SO or gas.
  • article 2 Citação(ões) na Scopus
    Spontaneous closure of degenerative lamellar macular hole with epiretinal membrane proliferation
    (2021) PRETI, Rony C.; ZACHARIAS, Leandro C.; CUNHA, Leonardo P.; MONTEIRO, Mario L. R.; SARRAF, David
    Background To describe the spontaneous closure of a degenerative lamellar macular hole with epiretinal proliferation (LHEP) as documented with tracked spectral domain optical coherence tomography (SD-OCT). Case presentation A 54-years-old diabetic female patient presented with progressive vision loss in the left eye. SD-OCT illustrated LHEP associated with cystic fluid in the outer nuclear layer. Sequentially tracked SD-OCT showed progressive closure of the degenerative lamellar macular hole and resolution of the CME over almost 4 years, in the absence of any surgical intervention. Discussion/conclusion LHEP may represent a specialized form of degenerative epiretinal membrane associated with Muller cell activation. Spontaneous degenerative LMH closure may rarely occur with these lesion types, in the absence of surgical intervention, possibly due to Muller cell proliferation preceded by PVD.