ALINE GOMES BITTENCOURT

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
LIM/32 - Laboratório de Otorrinolaringologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 5 de 5
  • article 10 Citação(ões) na Scopus
    Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation
    (2013) BENTO, Ricardo Ferreira; MONTEIRO, Tatiana Alves; BITTENCOURT, Aline Gomes; GOFFI-GOMEZ, Maria Valeria Schmidt; BRITO, Rubens de
    INTRODUCTION: Few cases of cochlear implantation (CI) in neurofibromatosis type 2 (NF2) patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. OBJECTIVES: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. RESUMED REPORT: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. CONCLUSION: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.
  • article 15 Citação(ões) na Scopus
    Cochlear Implantation Via the Middle Fossa Approach: Surgical and Programming Considerations
    (2012) BENTO, Ricardo Ferreira; BITTENCOURT, Aline Gomes; GOFFI-GOMEZ, Maria Valeria Schmidt; SAMUEL, Paola; TSUJI, Robinson Koji; BRITO, Rubens de
    Objectives: To report the results of cochlear implantation via the middle fossa approach in 4 patients, discuss the complications, and present a detailed description of the programming specifications in these cases. Study Design: Retrospective case review. Setting: Tertiary-care referral center with a well-established cochlear implant program. Patients: Four patients with bilateral canal wall down mastoid cavities who underwent the middle fossa approach for cochlear implantation. Interventions: Cochlear implantation and subsequent rehabilitation. A middle fossa approach with cochleostomy was successfully performed on the most superficial part of the apical turn in 4 patients. A Nucleus 24 cochlear implant system was used in 3 patients and a MED-EL Sonata Medium device in 1 patient. The single electrode array was inserted through a cochleostomy from the cochlear apex and occupied the apical, middle, and basal turns. Telemetry and intraoperative impedance recordings were performed at the end of surgery. A CT scan of the temporal bones was performed to document electrode insertion for all of the patients. Main Outcome Measures: Complications, hearing thresholds, and speech perception outcomes were evaluated. Results: Neural response telemetry showed present responses in all but 1 patient, who demonstrated facial nerve stimulation during the test. Open-set speech perception varied from 30% to 100%, despite the frequency allocation order of the MAP. Conclusion: Cochlear implantation via the middle cranial fossa is a safe approach, although it is a challenging procedure, even for experienced surgeons.
  • article 11 Citação(ões) na Scopus
    Remote programming of cochlear implants
    (2014) SAMUEL, Paola Angelica; GOFFI-GOMEZ, Maria Valéria Schmidt; BITTENCOURT, Aline Gomes; TSUJI, Robinson Koji; BRITO, Rubens de
    PURPOSE: To verify the effectiveness of remote programming of cochlear implants by stimulation levels and results in the perception of speech and free-field audiometry tests. METHODS: Twelve patients from both genders, aged between 18 and 59 years, users of internal cochlear implant and speech processor of the same model for at least 12 months, were selected. Both the remote programming (RP) and the live programming (LP) were performed on the same day, measuring the minimum (T) and maximum (C) stimulation levels of five electrodes with the interpolation of the remaining ones. Speech perception tests were applied using 65 dBSPL (recorded open context sentences and monosyllables). The patients were submitted to free-field audiometry at 250-8,000 Hz frequencies. The results for the RP and LP were compared. RESULTS: Differences in mean of the T levels for three electrodes and the C levels for one electrode were found. No difference between the results was obtained in the speech perception tests and audiometric thresholds in the RP and LP. CONCLUSION: The RP is a simple and effective procedure for programming cochlear implant devices and, although there were differences in the stimulation levels of some electrodes, it did not interfere in the speech perception outcomes.
  • article 7 Citação(ões) na Scopus
    Cochlear implants and bacterial meningitis: a speech recognition study in paired samples
    (2013) BRITO, Rubens de; BITTENCOURT, Aline Gomes; GOFFI-GOMEZ, Maria Valéria; MAGALHÃES, Ana Tereza; SAMUEL, Paola; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira
    INTRODUCTION: Cochlear implants may guarantee sound perception and the ability to detect speech at a close-to-normal hearing intensity; however, differences have been observed among implantees in terms of performance on discrimination tests and speech recognition. OBJECTIVE: To identify whether patients with post-meningitis deafness perform similarly to patients with hearing loss due to other causes. METHOD: A retrospective clinical study involving post-lingual patients who had been using Nucleus-22 or Nucleus-24 cochlear implants for at least 1 year. These patients were matched with respect to age (± 2 years), time since the onset of deafness (± 1 year), and the duration of implant use with implant users who had hearing loss due to other causes. Speech perception was assessed using the Portuguese version of the Latin-American Protocol for the Evaluation of Cochlear Implants. RESULTS: The sample consisted of 52 individuals (26 in each of the 2 groups). The post-meningitic group had a median of 18.5 active electrodes. The group with hearing loss due to other causes had a median of 21, but no significant statistical difference was observed (p = 0.07). The results of closed- and open-set speech recognition tests showed great variability in speech recognition between the studied groups. These differences were more pronounced for the most difficult listening tasks, such as the medial consonant task (in the vowel-consonant-vowel format). CONCLUSION: Cochlear implant recipients with hearing loss due to bacterial meningitis, who had been using the device for 1 year performed more poorly on closed- and open-set speech recognition tests than did implant recipients with hearing loss due to other causes.
  • article 5 Citação(ões) na Scopus
    Programming peculiarities in two cochlear implant users with superficial siderosis of the central nervous system
    (2012) BITTENCOURT, Aline Gomes; GOFFI-GOMEZ, Maria Valeria Schmidt; PINNA, Mariana Hausen; BENTO, Ricardo Ferreira; BRITO, Rubens de; TSUJI, Robinson Koji
    To report the audiological outcomes of cochlear implantation in two patients with severe to profound sensorineural hearing loss secondary to superficial siderosis of the CNS and discuss some programming peculiarities that were found in these cases. Retrospective review. Data concerning clinical presentation, diagnosis and audiological assessment pre- and post-implantation were collected of two patients with superficial siderosis of the CNS. Both patients showed good hearing thresholds but variable speech perception outcomes. One patient did not achieve open-set speech recognition, but the other achieved 70% speech recognition in quiet. Electrical compound action potentials could not be elicited in either patient. Map parameters showed the need for increased charge. Electrode impedances showed high longitudinal variability. The implants were fairly beneficial in restoring hearing and improving communication abilities although many reprogramming sessions have been required. The hurdle in programming was the need of frequent adjustments due to the physiologic variations in electrical discharges and neural conduction, besides the changes in the impedances. Patients diagnosed with superficial siderosis may achieve limited results in speech perception scores due to both cochlear and retrocochlear reasons. Careful counseling about the results must be given to the patients and their families before the cochlear implantation indication.