FAUZE MALUF FILHO

(Fonte: Lattes)
Índice h a partir de 2011
16
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina - Médico
Instituto do Câncer do Estado de São Paulo, Hospital das Clínicas, Faculdade de Medicina - Médico
LIM/37 - Laboratório de Transplante e Cirurgia de Fígado, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 6 de 6
  • article 4 Citação(ões) na Scopus
    PEG rescue with gastropexy after early tube withdrawal: an application of natural orifice transluminal endoscopic surgery (with video)
    (2011) MARTINS, Bruno da Costa; TAKADA, Jonas; KAWAGUTI, Fabio Shiguehissa; RIBEIRO, Joao Paulo Aguiar; HONDO, Fabio Yuji; LIMA, Marcelo Simas de; NEVES, Carla Zanellatto; NAHAS, Caio Sergio R.; MARQUES, Carlos Frederico Sparapan; SAKAI, Paulo; MALUF-FILHO, Fauze
  • article 3 Citação(ões) na Scopus
    OCULAR MELANOMA WITH MULTIPLE GASTROINTESTINAL METASTASES
    (2011) KAWAGUTI, Fabio Shiguehissa; MALUF-FILHO, Fauze; MEDEIROS, Raphael Salles S.; MARTINS, Bruno Da Costa; LIMA, Marcelo Simas De; HONDO, Fabio Yuji; NAHAS, Caio Sergio Rizkallah; MARQUES, Carlos Frederico Sparapan; SAKAI, Paulo
  • article 11 Citação(ões) na Scopus
    A new large-caliber trocar for percutaneous endoscopic gastrostomy by the introducer technique in head and neck cancer patients
    (2011) GIORDANO-NAPPI, J. H.; MALUF-FILHO, F.; ISHIOKA, S.; HONDO, F. Y.; MATUGUMA, S. E.; LIMA, M. Simas de; SANTOS, M. Lera dos; RETES, F. A.; SAKAI, P.
    Background and study aims In many patients, percutaneous endoscopic gastrostomy (PEG) can be limited by digestive tract stenosis. PEG placement using an introducer is the safest alternative for this group of patients, but the available devices are difficult to implement and require smaller-caliber tubes. The aim of this study was to evaluate the modification of an introducer technique device for PEG placement with regard to the following: procedure feasibility, possibility of using a 20-Fr balloon gastrostomy tube, tube-related function and problems, complications, procedure safety, and mortality. Patients and methods Between March 2007 and February 2008, 30 consecutive patients with head and neck malignancies underwent introducer PEG placement with the modified device and gastropexy. Each patient was evaluated for 60 days after the procedure for the success of the procedure, infection, pain, complications, mortality, and problems with the procedure. Results The procedure was successful in all cases with no perioperative complications. No signs of stomal infection were observed using the combined infection score. The majority of patients experienced mild-to-moderate pain both in the immediate postoperative period and at 72 hours. One major early complication (3.3%) and two minor complications (6.7%) were observed. No procedure-related deaths occurred during the first 60 days after the procedure. Conclusion The device modification for PEG using the introducer technique is feasible, safe, and efficient in outpatients with obstructive head and neck cancer. In this series, it allowed the use of a larger-caliber tube with low complication rates and no procedure-related mortality.
  • article 35 Citação(ões) na Scopus
    Narrow-band imaging without magnification for detecting early esophageal squamous cell carcinoma
    (2011) IDE, Edson; MALUF-FILHO, Fauze; CHAVES, Dalton Marques; MATUGUMA, Sergio Eiji; SAKAI, Paulo
    AIM: To compare narrow-band imaging (NBI) without image magnification, and chromoendoscopy with Lugol's solution for detecting high-grade dysplasia and intramucosal esophageal squamous cell carcinoma (SCC) in patients with head and neck cancer. METHODS: This was a prospective observational study of 129 patients with primary head and neck tumors consecutively referred to the Gastrointestinal Endoscopy Unit of Hospital das Clinicas, Sao Paulo University Medical School, Brazil, between August 2006 and February 2007. Conventional examinations with NBI and Lugol chromoendoscopy were consecutively performed, and the discovered lesions were mapped, recorded and sent for biopsy. The results of the three methods were compared regarding sensitivity, specificity, accuracy, positive predictive value, negative predictive value, positive likelihood value and negative likelihood value. RESULTS: Of the 129 patients, nine (7%) were diagnosed with SCC, 5 of which were in situ and 4 which were intramucosal. All carcinomas were detected through NBI and Lugol chromoendoscopy. Only 4 lesions were diagnosed through conventional examination, all of which were larger than 10 mm. CONCLUSION: NBI technology with optical filters has high sensitivity and high negative predictive value for detecting superficial esophageal SCC, and produces results comparable to those obtained with 2.5% Lugol chromoendoscopy.
  • article 4 Citação(ões) na Scopus
    Use of multiple channel pH monitoring for evaluation of ultra-distal reflux in patients after fundoplication for treatment of Barrett's esophagus
    (2011) SEGURO, F. C. B. C.; SANTO, M. A.; SZACHNOWICZ, S.; MALUF FILHO, F.; KISHI, H. S.; FALCAO, A. M.; NASI, A.; SALLUM, R. A. A.; CECCONELLO, I.
    Dysplasia and esophageal adenocarcinoma may arise in patients with Barrett's esophagus after fundoplication esophageal pH monitoring showing no acid in esophagus. This suggests the need to develop methodology to evaluate the occurrence of ultra-distal reflux (1 cm above the LES). The objective of the study was to compare acid exposition in three different levels: 5 cm above the upper border of the LES, 1 cm above the LES and in the intrasphincteric region. Eleven patients with Barrett's esophagus after Nissen fundoplication with no clinical, endoscopic and radiologic evidence of reflux were selected. Four-channel pH monitoring took place: channel A, 5 cm above the upper border of the LES; channel B, 1 cm above the LES; channel C, intrasphincteric; channel D, intragastric. The results of channels A, B and C were compared. There was significant increase in number of reflux episodes and a higher fraction of time with pH <4.0 in channel B compared to channel A. There was significant decrease in fraction of time with pH <4.0 in channel B compared to channel C. Two cases of esophageal adenocarcinoma were diagnosed in the studied patients. The region 1 cm above the upper border of the LES is more exposed to acid than the region 5 cm above the upper border of the LES, although this exposure occurred in reduced levels. The region 1 cm above the upper border of the LES is less exposed to acid than the intrasphincteric region.
  • article 34 Citação(ões) na Scopus
    Endoscopic treatment of Zenker's diyerticulum by harmonic scalpel
    (2011) HONDO, Fabio Yuji; MALUF-FILHO, Fauze; GIORDANO-NAPPI, Jose Humberto; NEVES, Carla Zanelatto; CECCONELLO, Ivan; SAKAI, Paulo
    Background: Zenker's diverticulum (ZD) is a rare condition with a reported prevalence of 0.01% to 0.11% in the general population. Endoscopic treatment consists of the division of the septum between the diverticulum and the esophagus, within which the cricopharyngeal muscle is contained. Diathermic monopolar current, argon plasma coagulation, and laser have been used to incise the muscular septum with satisfactory results. The main limitation of endoscopic treatment is the occurrence of complications. Perforation and hemorrhage are reported in as many as 23% and 10% of patients, respectively. Objective: The aim of this study was to use the technique of endoscopic diverticulotomy by using a harmonic scalpel in patients with ZD and to demonstrate the feasibility of using flexible and rigid devices in ZD treatment. Design: Case series study. Standard protocol was used for patient management, endoscopic procedure, and data collection. Setting: Single endoscopist demonstrating preliminary results. Patients: Five patients (4 men; median standard deviation [SD] age 69.6 +/- 9.06 years, range 59-83 years) with ZD were treated with this technique. All patients reported dysphagia and halitosis. The diagnosis was based on clinical, endoscopic, and radiographic findings. Interventions: All patients received general anesthesia and were placed in the left lateral position. A standard videogastroscope (9.8 mm) and a stiff guidewire were used to insert and achieve an adequate exposure of the ZD septum. The septum was divided using a harmonic scalpel under thin endoscope (5.2 mm) visualization through a soft diverticuloscope. Main Outcome Measurement: Feasibility of an endoscopic technique by using rigid and flexible devices to treat ZD. Results: Four patients (80%) were successfully treated in 1 session. The median SD size of the diverticulum was 3.6 +/- 0.89 cm (range 3-5 cm). Median SD procedure time was 17.33 +/- 2.33 minutes (range 15-20 minutes) in 6 procedures. No hemorrhage or perforation occurred. One patient (20%) required a second session to complete dissection of the ZD septum. All patients demonstrated improvement of dysphagia score after treatment. Limitations: Small case series design. Conclusions: Endoscopic treatment of ZD by harmonic scalpel through a soft diverticuloscope was feasible and effective in this small case series. Larger studies are warranted to further evaluate this technique.