ISAAC JOSE FELIPPE CORREA NETO

(Fonte: Lattes)
Índice h a partir de 2011
5
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • article 21 Citação(ões) na Scopus
    Are Obese Patients at an Increased Risk of Pelvic Floor Dysfunction Compared to Non-obese Patients?
    (2017) CORREA NETO, Isaac Jose Felippe; PINTO, Rodrigo Ambar; JORGE, Jose Marcio Neves; SANTO, Marco Aurelio; BUSTAMANTE-LOPEZ, Leonardo Alfonso; CECCONELLO, Ivan; NAHAS, Sergio Carlos
    Factors associated with increased intra-abdominal pressure such as chronic cough, morbid obesity, and constipation may be related to pelvic floor dysfunction. In this study, we compared anorectal manometry values and clinical data of class II and III morbidly obese patients referred to bariatric surgery with that of non-obese patients. We performed a case-matched study between obese patients referred to bariatric surgery and non-obese patients without anorectal complaints. The groups were matched by age and gender. Men and nulliparous women with no history of abdominal or anorectal surgery were included in the study. Anorectal manometry was performed by the stationary technique, and clinical evaluation was based on validated questionnaires. Mean age was 44.8 +/- 12.5 years (mean +/- SD) in the obese group and 44.1 +/- 11.8 years in the non-obese group (p = 0.829). In the obese group, 65.4% of patients had some degree of fecal incontinence. Mean squeeze pressure was significantly lower in obese than in non-obese patients (155.6 +/- 64.1 vs. 210.1 +/- 75.9 mmHg, p = 0.004), and there was no significant difference regarding mean rest pressure in obese patients compared to non-obese ones (63.7 +/- 23.1 vs. 74.1 +/- 21.8 mmHg, p = 0.051). There were no significant differences in anorectal manometry values between continent and incontinent obese patients. The prevalence of fecal incontinence among obese patients was high regardless of age, gender, and body mass index. Anal squeeze pressure was significantly lower in obese patients compared to non-obese controls.
  • article 1 Citação(ões) na Scopus
    Administration of an Anal Bulking Agent With Polyacrylate-Polyalcohol Copolymer Particles Versus Endoanal Electrical Stimulation With Biofeedback for the Management of Mild and Moderate Anal Incontinence: A Randomized Prospective Study
    (2022) CORREA NETO, Isaac J. F.; PINTO, Rodrigo A.; BRANDAO, Debora G.; BATISTA, Patricia A.; BUSTAMANTE-LOPEZ, Leonardo A.; CECCONELLO, Ivan; NAHAS, Sergio C.
    BACKGROUND: There are few treatment options for mild-to-moderate anal incontinence with isolated internal anal sphincter defects or anal incontinence without muscle damage. Less-invasive techniques are generally favored. OBJECTIVE: To compare the results between the use of an anal bulking agent with polyacrylate-polyalcohol copolymer particles and endoanal electrical stimulation with biofeedback in patients with mild or moderate anal incontinence. DESIGN: This was a prospective parallel-group, single-institution, randomized clinical trial. SETTINGS: This study was conducted in an ambulatory setting at the Colorectal Physiology Service of the Hospital das Clinicas, Medical School, University of Sao Paulo. PATIENTS: This study included patients who had anal incontinence for >6 months with isolated internal anal sphincter muscle damage or absence of anatomical defects in the anorectal sphincter complex. INTERVENTIONS: Anal bulking agent and endoanal electrical stimulation with biofeedback. MAIN OUTCOME MEASURES: The primary outcome measure was the Cleveland Clinic Florida Fecal Incontinence Score, and the secondary outcome measures included quality of life, recommended procedures, and anorectal manometry. RESULTS: There were no significant between-group differences in mean age, sex, BMI, stool consistency, and Cleveland Clinic Florida Fecal Incontinence Score (p = 0.20) at baseline. After 12 months, the Cleveland Clinic Florida Fecal Incontinence Score was found to be significantly improved in patients treated with the bulking agent compared to those treated with electrical stimulation (mean, 6.2 vs 9.2; p = 0.002), though the anorectal manometry parameters did not change significantly. The mean anal Cleveland Clinic Florida Fecal Incontinence Score declined by 4.2 points in the bulking agent group compared to a decline of 0.8 in the electrical stimulation group (mean difference in decline: 3.4 points; 95% CI, 1.2-5.5). Quality-of life evaluation showed similar results between groups comparing baseline parameters with 12-month follow-up. LIMITATIONS: The short follow-up period of 1 year, atypical method of biofeedback, and unmatched baseline in some of the quality-of-life scales between the 2 groups limited this study. CONCLUSIONS: In patients with mild or moderate anal incontinence, the Cleveland Clinic Florida Fecal Incontinence Score significantly improved in the bulking agent with polyacrylate-polyalcohol copolymer group compared with the endoanal electrical stimulation with biofeedback group.
  • article 1 Citação(ões) na Scopus
    ANORECTAL MANOMETRY STANDARD OF A BRAZILIAN POPULATION AT PRODUCTIVE AGE WITHOUT PELVIC FLOOR DISORDERS: A PROSPECTIVE VOLUNTEERED STUDY
    (2021) PINTO, Rodrigo Ambar; CORREA-NETO, Isaac Jose Felippe; BUSTAMANTE-LOPEZ, Leonardo Alfonso; NAHAS, Caio Sergio R.; MARQUES, Carlos Frederico S.; SOBRADO-JUNIOR, Carlos Walter; CECCONELLO, Ivan; NAHAS, Sergio Carlos
    Background: Due to the lack of normal standards of anorectal manometry in Brazil, data used are subject to normality patterns described at different nationalities. Aim: To determine the values and range of the parameters evaluated at anorectal manometry in people, at productive age, without pelvic floor disorders comparing the parameters obtained between male and female. Methods: Prospective analysis of clinical data, such as gender, age, race, body mass index (BMI) and anorectal manometry, of volunteers from a Brazilian university reference in pelvic floor disorders. Results: Forty patients were included, with a mean age of 45.5 years in males and 37.2 females (p=0.43). According to male and female, respectively in mmHg, resting pressures were similar (78.28 vs. 63.51, p=0.40); squeeze pressures (153.89 vs. 79.78, p=0.007) and total squeeze pressures (231.27 vs. 145.63, p=0.002). Men presented significantly higher values of anorectal squeeze pressures, as well as the average length of the functional anal canal (2.85 cm in male vs. 2.45 cm in female, p=0.003). Conclusions: Normal sphincter pressure levels in Brazilians differ from those used until now as normal literature standards. Male gender has higher external anal sphincter tonus as compared to female, in addition a greater extension of the functional anal canal