Comparative analysis of scaphoid nonunion treatment with screw fixation and angular stable plate

Carregando...
Imagem de Miniatura
Citações na Scopus
4
Tipo de produção
article
Data de publicação
2023
Título da Revista
ISSN da Revista
Título do Volume
Editora
SPRINGER
Citação
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v.143, n.4, p.2247-2253, 2023
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
Introduction Scaphoid fractures represent 5-10% of nonunion rate and the treatment options consist of an open reduction with correction of deformity, restoration of the scaphoid length with autologous wedge grafting and fixation. However, there is still no consensus in the literature on the best fixation method. Therefore, the purpose of the study is to compare plate fixation and screw fixation in treating scaphoid nonunion with humpback deformity and carpal instability. Methods Prospective, non-randomised study comparing the treatment of two groups of patients with scaphoid nonunion. A total of 19 patients were included in the study, the first ten patients were included in group 1 (plate fixation), subsequently nine patients were included in group 2 (screw fixation). The nonunion duration was longer than 6 months and patients did not present type III Scaphoid Nonunion Advanced Collapse (SNAC). Clinical evaluations included pain intensity, range of motion, grip strength, pinch test and functional scales Disabilities of the Arm, Shoulder and Hand (DASH) and Mayo Wrist Score. Radiographic evaluations consisted of radiographs of both wrists in AP, AP with ulnar deviation, lateral and oblique views. Patients further underwent a tomography of the affected wrist for bone deformity, carpal collapse and later consolidation evaluation. Results According to post-operative measurements, group 1 showed a significant improvement in the scapholunate angle (p = 0.011) and in the intrascaphoid angle (p = 0.002). Group 2 only showed an improvement in the scapholunate angle (p = 0.011). All patients in group 1 achieved consolidation in 8 weeks, while group 2 patients had a slower consolidation, with a mean of 14 weeks and standard deviation (SD) of 4.2, with statistical significance (p = 0.006). Conclusion Our prospective study, despite the limitations, contributes to the literature for demonstrating a better fixation using plate, with a better correction of humpback deformity and Dorsal Intercalated Segment Instability (DISI) and a faster consolidation.
Palavras-chave
Pseudoarthrosis, Scaphoid bone, surgery, Fracture fixation, internal, Bone plates, Bone screws, Scaphoid bone, injuries
Referências
  1. ALNOT JY, 1988, REV CHIR ORTHOP, V74, P700
  2. AMADIO PC, 1989, J HAND SURG-AM, V14A, P679, DOI 10.1016/0363-5023(89)90191-3
  3. BRAUN C, 1993, UNFALLCHIRURG, V96, P9
  4. BURGESS RC, 1987, J HAND SURG-AM, V12A, P774, DOI 10.1016/S0363-5023(87)80067-9
  5. Burgos FH, 2019, ACTA ORTOP BRAS, V27, P141, DOI 10.1590/1413-785220192703214849
  6. Capito AE, 2013, J HAND SURG-AM, V38A, P2419, DOI 10.1016/j.jhsa.2013.09.035
  7. Dias J, 2020, HEALTH TECHNOL ASSES, V24, P1, DOI 10.3310/hta24520
  8. Duckworth AD, 2012, J TRAUMA ACUTE CARE, V72, pE41, DOI 10.1097/TA.0b013e31822458e8
  9. ENDER HG, 1977, UNFALLHEILKUNDE, V80, P509
  10. Hove LM, 1999, SCAND J PLAST RECONS, V33, P423, DOI 10.1080/02844319950159145
  11. Jurkowitsch J, 2016, ARCH ORTHOP TRAUM SU, V136, P1623, DOI 10.1007/s00402-016-2556-z
  12. Leixnering M, 2011, J TRAUMA, V71, P933, DOI 10.1097/TA.0b013e3181f65721
  13. Mathoulin CL, 2018, J HAND SURG-EUR VOL, V43, P13, DOI 10.1177/1753193417739526
  14. NAKAMURA R, 1993, J HAND SURG-BRIT EUR, V18B, P219, DOI 10.1016/0266-7681(93)90114-U
  15. NAKAMURA R, 1987, J HAND SURG-AM, V12A, P1000, DOI 10.1016/S0363-5023(87)80097-7
  16. Pinder RM, 2015, J HAND SURG-AM, V40, P1797, DOI 10.1016/j.jhsa.2015.05.003
  17. Talia AJ, 2019, J ORTHOP, V16, P337, DOI 10.1016/j.jor.2019.03.005
  18. Van Tassel DC, 2010, J HAND SURG-AM, V35A, P1242, DOI 10.1016/j.jhsa.2010.05.017
  19. WARRENSMITH CD, 1988, J HAND SURG-BRIT EUR, V13B, P83, DOI 10.1016/0266-7681(88)90060-5