A COMPUTERIZED SYSTEM FOR THE APPLICATION OF BASSO, BEATTIE AND BRESNAHAN SCALE IN WISTAR RATS
dc.contributor | Sistema FMUSP-HC: Faculdade de Medicina da Universidade de São Paulo (FMUSP) e Hospital das Clínicas da FMUSP | |
dc.contributor.author | MOLINA, Alessandra Eira Iague Sleiman | |
dc.contributor.author | CRISTANTE, Alexandre Fogca | |
dc.contributor.author | BARROS FILHO, Tarcisio Eloy Pessoa de | |
dc.contributor.author | MOLINA, Marcos Sleiman | |
dc.contributor.author | MOLINA, Taina Peral | |
dc.date.accessioned | 2015-10-26T16:30:50Z | |
dc.date.available | 2015-10-26T16:30:50Z | |
dc.date.issued | 2015 | |
dc.description.abstract | Objectives: To develop and test a computer program to assist researchers in assigning scores in the application of the Basso, Beattie and Bresnahan (BBB) scale and to compare these scores when doing so in free, targeted and automated computer-assisted modes. Method: To test the program, the participants used the Impactor methodology recommended by the New York University (USA), in which 12 Wistar rats submitted to spinal cord injury were filmed on the 28th day after the injury. Eight researchers from the Laboratory of Medical Investigation, Faculdade de Medicina da Universidade de Sao Paulo, SP, Brazil took part in the study. The two heads of the laboratory, with 15 years of experience in the application of the scale, were considered the gold standard. Results: The results of the scale application were not significantly different in relation to the gold standard, considering the mean of the evaluators in each method: free, targeted and automated form (with the help of the computer). Conclusions: The application of the BBB scale in the automated mode, using the computer program, did not present any difference in relation to the gold standard for all the evaluators. | |
dc.description.index | PubMed | |
dc.identifier.citation | ACTA ORTOPEDICA BRASILEIRA, v.23, n.4, p.179-183, 2015 | |
dc.identifier.doi | 10.1590/1413-78522015230400673 | |
dc.identifier.eissn | 1809-4406 | |
dc.identifier.issn | 1413-7852 | |
dc.identifier.uri | https://observatorio.fm.usp.br/handle/OPI/11739 | |
dc.language.iso | eng | |
dc.publisher | ATHA COMUNICACAO & EDITORA | |
dc.relation.ispartof | Acta Ortopedica Brasileira | |
dc.rights | openAccess | |
dc.rights.holder | Copyright ATHA COMUNICACAO & EDITORA | |
dc.subject | Spine | |
dc.subject | Methods | |
dc.subject | Spinal cord compression | |
dc.subject | Evaluation | |
dc.subject | Diagnosis, computer-assisted | |
dc.subject | Rats | |
dc.subject.other | spinal-cord-injury | |
dc.subject.other | rating-scale | |
dc.subject.wos | Orthopedics | |
dc.title | A COMPUTERIZED SYSTEM FOR THE APPLICATION OF BASSO, BEATTIE AND BRESNAHAN SCALE IN WISTAR RATS | |
dc.type | article | |
dc.type.category | original article | |
dc.type.version | publishedVersion | |
dspace.entity.type | Publication | |
hcfmusp.author.external | MOLINA, Alessandra Eira Iague Sleiman:Univ Sao Paulo, Fac Med, Dept Ortopedia & Traumatol, Sao Paulo, SP, Brazil | |
hcfmusp.author.external | MOLINA, Marcos Sleiman:Univ Sao Paulo, Hosp Clin, Fac Med, Inst Coracao InCor, Sao Paulo, SP, Brazil | |
hcfmusp.author.external | MOLINA, Taina Peral:Fundacao Lusiada, Fac Ciencias Med Santos, Santos, SP, Brazil | |
hcfmusp.citation.scopus | 8 | |
hcfmusp.contributor.author-fmusphc | ALEXANDRE FOGACA CRISTANTE | |
hcfmusp.contributor.author-fmusphc | TARCISIO ELOY PESSOA DE BARROS FILHO | |
hcfmusp.description.beginpage | 179 | |
hcfmusp.description.endpage | 183 | |
hcfmusp.description.issue | 4 | |
hcfmusp.description.volume | 23 | |
hcfmusp.origem | WOS | |
hcfmusp.origem.scielo | SCIELO:S1413-78522015000400179 | |
hcfmusp.origem.scopus | 2-s2.0-84940371060 | |
hcfmusp.origem.wos | WOS:000359477000001 | |
hcfmusp.publisher.city | SAO PAULO SP | |
hcfmusp.publisher.country | BRAZIL | |
hcfmusp.relation.reference | Barros Filho TEP, 1995, COLUNA VERTEBRAL DIA | |
hcfmusp.relation.reference | Basso DM, 1996, EXP NEUROL, V139, P244, DOI 10.1006/exnr.1996.0098 | |
hcfmusp.relation.reference | BASSO DM, 1995, J NEUROTRAUM, V12, P1, DOI 10.1089/neu.1995.12.1 | |
hcfmusp.relation.reference | CONSTANTINI S, 1994, J NEUROSURG, V80, P97, DOI 10.3171/jns.1994.80.1.0097 | |
hcfmusp.relation.reference | Cristante AF, 2010, ACTA ORTOP BRAS, V18, P284, DOI 10.1590/S1413-78522010000500008 | |
hcfmusp.relation.reference | FAIRHOLM DJ, 1971, J NEUROSURG, V35, P277, DOI 10.3171/jns.1971.35.3.0277 | |
hcfmusp.relation.reference | Ferguson AR, 2004, J NEUROTRAUM, V21, P1601, DOI 10.1089/0897715042441747 | |
hcfmusp.relation.reference | Jakeman LB, 2005, ANIMAL MODELS ACUTE, P433 | |
hcfmusp.relation.reference | Koopmans GC, 2005, J NEUROTRAUM, V22, P214, DOI 10.1089/neu.2005.22.214 | |
hcfmusp.relation.reference | Kuhn PL, 1998, J NEUROTRAUM, V15, P125, DOI 10.1089/neu.1998.15.125 | |
hcfmusp.relation.reference | Metz GAS, 2000, BRAIN RES, V883, P165, DOI 10.1016/S0006-8993(00)02778-5 | |
hcfmusp.relation.reference | Molina AEIS, 2006, THESIS U SAO PAULO S | |
hcfmusp.relation.reference | PANJABI MM, 1988, SPINE, V13, P1365, DOI 10.1097/00007632-198812000-00007 | |
hcfmusp.relation.reference | Rodrigues NR, 1999, THESIS U SAO PAULO S | |
hcfmusp.relation.reference | dos Santos GB, 2011, ACTA ORTOP BRAS, V19, P87, DOI 10.1590/S1413-78522011000200005 | |
hcfmusp.relation.reference | Scheff SW, 2002, J NEUROTRAUM, V19, P1251, DOI 10.1089/08977150260338038 | |
hcfmusp.relation.reference | TARLOV IM, 1954, AMA ARCH NEUROL PSY, V71, P588 | |
hcfmusp.relation.reference | Vialle LRG, 1999, REV BRAS ORTOP, V34, P85 | |
hcfmusp.relation.reference | Yeo J D, 1975, Paraplegia, V12, P279 | |
hcfmusp.scopus.lastupdate | 2024-05-10 | |
relation.isAuthorOfPublication | 761088b7-396d-4150-902e-319c7a85c457 | |
relation.isAuthorOfPublication | 92868e70-2c3f-49b7-86ec-fe73d0eb887a | |
relation.isAuthorOfPublication.latestForDiscovery | 761088b7-396d-4150-902e-319c7a85c457 |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- art_MOLINA_A_COMPUTERIZED_SYSTEM_FOR_THE_APPLICATION_OF_BASSO_2015.PDF
- Tamanho:
- 210.71 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
- publishedVersion (English)