Please use this identifier to cite or link to this item:
https://observatorio.fm.usp.br/handle/OPI/4178
Title: | The performance of four molecular methods for the laboratory diagnosis of congenital toxoplasmosis in amniotic fluid samples |
Authors: | TEIXEIRA, Leandro Emidio; KANUNFRE, Kelly Aparecida; SHIMOKAWA, Paulo Tadashi; TARGA, Lilia Spaleta; RODRIGUES, Jonatas Cristian; DOMINGUES, Wilson; YAMAMOTO, Lidia; OKAY, Thelma Suely |
Citation: | REVISTA DA SOCIEDADE BRASILEIRA DE MEDICINA TROPICAL, v.46, n.5, p.584-588, 2013 |
Abstract: | Introduction: Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods: Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results: Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions: The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (co), NLR (0.017), and Ef (99%). |
Appears in Collections: | Artigos e Materiais de Revistas Científicas - FM/MPE Artigos e Materiais de Revistas Científicas - HC/ICr Artigos e Materiais de Revistas Científicas - IMT Artigos e Materiais de Revistas Científicas - LIM/36 Artigos e Materiais de Revistas Científicas - LIM/48 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
art_KANUNFRE_The_performance_of_four_molecular_methods_for_the_2013.PDF | publishedVersion (English) | 716.54 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.