Título: Applying the National Institute for Clinical Excellence criteria to patients treated with the Genous (TM) Bio-engineered R stent (TM): a sub-study of the e-HEALING (Healthy Endothelial Accelerated Lining Inhibits Neointimal Growth) worldwide registry
Autor(es): KLOMP, MargoDAMMAN, PeterBEIJK, Marcel A. M.SILBER, SigmundGRISOLD, ManfredRIBEIRO, Expedito E.SURYAPRANATA, HarryWOJCIK, JaroslawSIM, Kui HianTIJSSEN, Jan G. P.WINTER, Robbert J. de
Parte de: HEART AND VESSELS, v.27, n.4, p.360-369, 2012
Resumo: The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter a parts per thousand yen3 mm and lesion length a parts per thousand currency sign15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter < 3.0 mm or lesion length > 15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with a parts per thousand yen1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.
Aparece nas coleções:

Artigos e Materiais de Revistas Científicas - HC/InCor
Instituto do Coração - HC/InCor


Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
art_RIBEIRO_Applying_the_National_Institute_for_Clinical_Excellence_criteria_2012.PDF
  Restricted Access
publishedVersion (English)288.86 kBAdobe PDFVisualizar/Abrir    Solicitar uma cópia

Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.