Please use this identifier to cite or link to this item:
https://observatorio.fm.usp.br/handle/OPI/1866
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor | Sistema FMUSP-HC: Faculdade de Medicina da Universidade de São Paulo (FMUSP) e Hospital das Clínicas da FMUSP | - |
dc.contributor.author | RODRIGUES, Olavo Ribeiro | - |
dc.contributor.author | MINAMOTO, Helio | - |
dc.contributor.author | CANZIAN, Mauro | - |
dc.contributor.author | CORREIA, Aristides Tadeu | - |
dc.contributor.author | JATENE, Fabio Biscegli | - |
dc.date.accessioned | 2013-09-23T16:36:43Z | - |
dc.date.available | 2013-09-23T16:36:43Z | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | ACTA CIRURGICA BRASILEIRA, v.28, n.1, p.10-18, 2013 | - |
dc.identifier.issn | 0102-8650 | - |
dc.identifier.uri | https://observatorio.fm.usp.br/handle/OPI/1866 | - |
dc.description.abstract | PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study. | - |
dc.language.iso | eng | - |
dc.publisher | ACTA CIRURGICA BRASILEIRA | - |
dc.relation.ispartof | Acta Cirurgica Brasileira | - |
dc.rights | openAccess | - |
dc.subject | Stents | - |
dc.subject | Tracheal Stenosis | - |
dc.subject | Materials Testing | - |
dc.subject | Rats | - |
dc.subject.other | model | - |
dc.subject.other | stenosis | - |
dc.subject.other | dogs | - |
dc.title | Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent. Comparative study in rats | - |
dc.type | article | - |
dc.rights.holder | Copyright ACTA CIRURGICA BRASILEIRA | - |
dc.identifier.doi | 10.1590/S0102-86502013000100003 | - |
dc.identifier.pmid | 23338108 | - |
dc.subject.wos | Surgery | - |
dc.type.category | original article | - |
dc.type.version | publishedVersion | - |
hcfmusp.author.external | RODRIGUES, Olavo Ribeiro:Univ Mogi das Cruzes, Div Gen Thorac Surg, Mogi das Cruzes, SP, Brazil | - |
hcfmusp.description.beginpage | 10 | - |
hcfmusp.description.endpage | 18 | - |
hcfmusp.description.issue | 1 | - |
hcfmusp.description.volume | 28 | - |
hcfmusp.origem | WOS | - |
hcfmusp.origem.id | 2-s2.0-84872940583 | - |
hcfmusp.origem.id | WOS:000313866600002 | - |
hcfmusp.origem.id | SCIELO:S0102-86502013000100003 | - |
hcfmusp.publisher.city | SAO PAULO | - |
hcfmusp.publisher.country | BRAZIL | - |
hcfmusp.relation.reference | Chen ZF, 2012, INT J PEDIATR OTORHI, V76, P183, DOI 10.1016/j.ijporl.2011.10.023 | - |
hcfmusp.relation.reference | Faria Celso Murilo Nálio Matias de, 2012, J Bras Pneumol, V38, P214 | - |
hcfmusp.relation.reference | Fraga JC, 1997, ARCH OTOLARYNGOL, V123, P522 | - |
hcfmusp.relation.reference | Kwon OJ, 2003, EXP LUNG RES, V29, P329, DOI 10.1080/01902140390116517 | - |
hcfmusp.relation.reference | Lee SS, 2008, J VASC INTERV RADIOL, V19, P764, DOI 10.1016/j.jvir.2008.01.025 | - |
hcfmusp.relation.reference | Liu KS, 2011, J THORAC CARDIOV SUR, V141, P463, DOI 10.1016/j.jtcvs.2010.08.008 | - |
hcfmusp.relation.reference | Lochbihler H, 1997, J PEDIATR SURG, V32, P717, DOI 10.1016/S0022-3468(97)90013-0 | - |
hcfmusp.relation.reference | Novotny L, 2012, J THORAC CARDIOV SUR, V143, P437, DOI 10.1016/j.jtcvs.2011.08.002 | - |
hcfmusp.relation.reference | Ruegemer JL, 1999, OTOLARYNG HEAD NECK, V121, P92, DOI 10.1016/S0194-5998(99)70132-4 | - |
hcfmusp.relation.reference | Shin JH, 2010, J VASC INTERV RADIOL, V21, P1878, DOI 10.1016/j.jvir.2010.09.007 | - |
hcfmusp.relation.reference | Terra Ricardo Mingarini, 2006, J Bras Pneumol, V32, P606, DOI 10.1590/S1806-37132006000600024 | - |
hcfmusp.relation.reference | Tsakayannis DE, 1998, J PEDIATR SURG, V33, P1038, DOI 10.1016/S0022-3468(98)90527-9 | - |
hcfmusp.relation.reference | Vaidergorn J, 2008, ACTA CIR BRAS, V23, P497, DOI 10.1590/S0102-86502008000600005 | - |
hcfmusp.relation.reference | Xavier Rogério Gastal, 2008, J Bras Pneumol, V34, P21, DOI 10.1590/S1806-37132008000100005 | - |
dc.description.index | MEDLINE | - |
hcfmusp.citation.scopus | 6 | - |
hcfmusp.scopus.lastupdate | 2022-05-06 | - |
Appears in Collections: | Artigos e Materiais de Revistas Científicas - FM/MCP Artigos e Materiais de Revistas Científicas - HC/ICHC Artigos e Materiais de Revistas Científicas - HC/InCor Artigos e Materiais de Revistas Científicas - LIM/11 Artigos e Materiais de Revistas Científicas - LIM/61 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
art_MINAMOTO_Biocompatibility_of_a_new_device_of_self_expandable_2013.PDF | publishedVersion (English) | 1.64 MB | Adobe PDF | ![]() View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.