Please use this identifier to cite or link to this item: https://observatorio.fm.usp.br/handle/OPI/30877
Title: Accuracy of Ultrasonography in the Evaluation of Tubal Sterilization Microinsert Positioning: Systematic Review and Meta-analysis
Authors: CARRETTI, MayraSIMOES, Ricardo dos SantosBERNARDO, Wanderley MarquesPINHEIRO, WalterPEREIRA, Anne Kristhine CavalcanteBARACAT, Maria Candida PinheiroSOARES JUNIOR, Jose MariaBARACAT, Edmund Chada
Citation: JOURNAL OF ULTRASOUND IN MEDICINE, v.38, n.2, p.289-297, 2019
Abstract: The current reference standard to check the position of a tubal sterilization microinsert device after its insertion is hysterosalpingography. The objective of this study was to evaluate the accuracy of 2-dimensional (2D) and 3-dimensional (3D) ultrasonography (US) in the positioning of the tubal sterilization microinsert for definitive contraception. We searched MEDLINE, Embase, Cochrane, and Scopus databases through October 2017. Selection criteria included studies that analyzed the accuracy of 2D or 3D US, or both, with respect to the positioning of the microinsert. Data were displayed as forest plots and a summary receiver operating characteristic curves. Values for sensitivity, specificity, and positive and negative likelihood ratios (LRs) were calculated. The pooled analysis produced sensitivity and specificity values for 2D US in the positioning of the microinsert of 0.88 (95% confidence interval [CI], 0.47-1.0) and 0.92 (95% CI, 0.88-0.95), respectively, with positive and negative LRs of 8.68 (95% CI, 1.63-46.1) and 0.35 (95% CI, 0.11-1.11), respectively. Three studies analyzed the performance of 3D US, showing sensitivity, specificity, and positive and negative LRs of 0.75 (95% CI, 0.35-0.97), 0.82 (95% CI, 0.77-0.87), 3.65 (95% CI, 2.31-5.75), and 0.46 (95% CI, 0.2-1.09). In conclusion, 2D and 3D US are methods that show good accuracy in tubal sterilization microinsert positioning.
Appears in Collections:

Artigos e Materiais de Revistas Científicas - FM/MOG
Departamento de Obstetrícia e Ginecologia - FM/MOG

Artigos e Materiais de Revistas Científicas - HC/ICESP
Instituto do Câncer do Estado de São Paulo - HC/ICESP

Artigos e Materiais de Revistas Científicas - HC/ICHC
Instituto Central - HC/ICHC

Artigos e Materiais de Revistas Científicas - HU
Hospital Universitário - HU

Artigos e Materiais de Revistas Científicas - LIM/58
LIM/58 - Laboratório de Ginecologia Estrutural e Molecular

Artigos e Materiais de Revistas Científicas - ODS/03
ODS/03 - Saúde e bem-estar


Files in This Item:
File Description SizeFormat 
art_CARRETTI_Accuracy_of_Ultrasonography_in_the_Evaluation_of_Tubal_2019.PDF
  Restricted Access
publishedVersion (English)1.8 MBAdobe PDFView/Open Request a copy

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.