Por favor, use este identificador para citar o enlazar este ítem: https://observatorio.fm.usp.br/handle/OPI/31971
Título: Accuracy of magnetic resonance imaging (MRI) for subscapularis tear: a systematic review and meta-analysis of diagnostic studies
Autor: MALAVOLTA, Eduardo AngeliASSUNCAO, Jorge HenriqueGRACITELLI, Mauro Emilio ConfortoYEN, Talitha KooBORDALO-RODRIGUES, MarceloFERREIRA NETO, Arnaldo Amado
Citación: ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v.139, n.5, p.659-667, 2019
Resumen: Introduction The accuracy of MRI for subscapularis tear is lower than that of overall rotator cuff tears. Until now, no systematic reviews and meta-analysis have been conducted to compile these data. The purpose of this study was to determine, through a systematic review and meta-analysis, the diagnostic accuracy of MRI in the detection of subscapularis tendon tears. Materials and methods A systematic review of PubMed, EMBASE, and MEDLINE databases up to April 2017 was performed. All studies assessing the sensitivity and specificity of the MRI (index test) compared to arthroscopic surgical findings (reference test) for subscapularis tendon tear were included. A meta-analysis was performed to calculate pooled sensitivity, specificity, sROC curve, and diagnostic odds ratio values. Results A total of 497 citations were identified. After applying the eligibility criteria, 14 articles were included, including 1858 shoulders with 613 subscapularis tears. For overall subscapularis tears, sensitivity was 0.68 (95% CI 0.64-0.72) and specificity was 0.90 (95% CI 0.89-0.92). Sensitivity was 0.93 (95% CI 0.83-0.98) for full-thickness tears and 0.74 (95% CI 0.66-0.82) for partial tears. Specificity was 0.97 (95% CI 0.94-0.98) for full-thickness tears and 0.88 (95% CI 0.85-0.91) for partial tears. Analyzing only studies with field of strength1.5T, sensitivity was 0.80 (95% CI 0.76-0.84) and specificity 0.84 (95% CI 0.81-0.87). Conclusion MRI is an accurate method for diagnosing subscapularis tendon tears; however, its accuracy is lower than that of overall rotator cuff tears, due to its lower sensitivity.
Aparece en las colecciones:

Artigos e Materiais de Revistas Científicas - HC/IOT
Instituto de Ortopedia e Traumatologia - HC/IOT

Artigos e Materiais de Revistas Científicas - LIM/41
LIM/41 - Laboratório de Investigação Médica do Sistema Músculoesquelético


Ficheros en este ítem:
Fichero Descripción TamañoFormato 
art_MALAVOLTA_Accuracy_of_magnetic_resonance_imaging_MRI_for_subscapularis_2019.PDFpublishedVersion (English)2.26 MBAdobe PDFVista previa
Visualizar/Abrir

Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.