Por favor, use este identificador para citar o enlazar este ítem: https://observatorio.fm.usp.br/handle/OPI/34278
Título: Accuracy of global and/or regional anthropometric measurements of adiposity in screening sleep apnea: the ELSA-Brasil cohort
Autor: SANTOS, Ronaldo B.SILVA, Wagner A.PARISE, Barbara K.GIATTI, SorayaAIELO, Aline N.SOUZA, Silvana P.SANTOS, Itamar S.LOTUFO, Paulo A.BENSENOR, Isabela M.DRAGER, Luciano F.
Citación: SLEEP MEDICINE, v.63, p.115-121, 2019
Resumen: Objective: Adiposity is a well-established risk factor for obstructive sleep apnea (OSA) but the existence of a preferable anthropometric measurement is not established or whether the combination of measurements may improve the accuracy to detect OSA. This study aimed to compare the accuracies of body mass index (BMI), several surrogate markers of body fat (in isolation or combined) and validated questionnaires for screening OSA. Methods: A total of 2059 participants from the ELSA-Brasil study given anthropometric measurements using standard procedures and a home sleep study. OSA was defined by an apnea-hypopnea index >= 15 events/hour. Results: The frequency of OSA was 32.3%. Compared with the non-OSA group, all anthropometric measurements were higher in the OSA group. Age and gender-adjusted BMI afforded the highest accuracy to detect OSA [AUC = 0.760 (0.739-0.781)], followed by waist [AUC = 0.753 (0.732-0.775)] and neck [AUC = 0.733 (0.711-0.755)] circumferences, waist-to-hip ratio [AUC = 0.722 (0.699-0.745)] and body shape index [AUC = 0.680 (0.656-0.704)]. The combination of two or more anthropometric measurements did not improve the accuracy of BMI in predicting OSA. The adjusted BMI had similar predictive performance to the NoSAS score [AUC = 0.748 (0.727-0.770)] but a better accuracy than the Berlin Questionnaire [AUC = 0.676 (0.653-0.699)]. Conclusions: Despite one's intuition, surrogate markers of regional adiposity are not better than BMI in screening OSA. Combining measurements of global and/or regional adiposity did not have additional value in detecting OSA. The merely fair accuracy range of BMI and sleep questionnaires underscore the need for additional tools to improve OSA underdiagnosis.
Aparece en las colecciones:

Artigos e Materiais de Revistas Científicas - FM/MCM
Departamento de Clínica Médica - FM/MCM

Artigos e Materiais de Revistas Científicas - HC/InCor
Instituto do Coração - HC/InCor

Artigos e Materiais de Revistas Científicas - HU
Hospital Universitário - HU

Artigos e Materiais de Revistas Científicas - LIM/20
LIM/20 - Laboratório de Terapêutica Experimental

Artigos e Materiais de Revistas Científicas - LIM/63
LIM/63 - Laboratório de Investigação Médica em Sono


Ficheros en este ítem:
Fichero Descripción TamañoFormato 
art_SANTOS_Accuracy_of_global_andor_regional_anthropometric_measurements_of_2019.PDFpublishedVersion (English)515.53 kBAdobe PDFVista previa
Visualizar/Abrir

Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.