Title: Use of remote control in the intraoperative telemetry of cochlear implant: multicentric study
Authors: TANAMATI, Liege FranziniGOFFI-GOMEZ, Maria Valeria SchmidtMUNIZ, Lilian FerreiraSAMUEL, Paola AngelicaWIEMES, Gislaine Richter MinhotoLIMA, Daniele PennaCURI, Silvia BadurONUKI, Lucia CristinaQUEIROZ, Carla FortunatoCAPISTRANO, Ana Karla BigoisMORET, Adriane Lima MortariKIMURA, Marcia Yuri TsumuraOYANGUREN, ValeriaMAUCH, Herbert
Citation: BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, v.85, n.4, p.502-509, 2019
Abstract: Introduction: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220 (R)) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. Objective: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. Methods: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220 (R) were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. Results: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. Conclusion: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry. (C) 2018 Associacao Brasileira de Otorrinolaringologia e Cirurgia Cervico-Facial.
Appears in Collections:

Artigos e Materiais de Revistas Científicas - HC/ICHC
Instituto Central - HC/ICHC

Artigos e Materiais de Revistas Científicas - LIM/32
LIM/32 - Laboratório de Otorrinolaringologia


Files in This Item:
File Description SizeFormat 
art_TANAMATI_Use_of_remote_control_in_the_intraoperative_telemetry_2019.PDFpublishedVersion (English)983.5 kBAdobe PDFThumbnail
View/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.