Please use this identifier to cite or link to this item:
https://observatorio.fm.usp.br/handle/OPI/4130
Title: | Modulation transfer function and optical quality after bilateral implantation of a+3.00 D versus a+4.00 D multifocal intraocular lens |
Authors: | SANTHIAGO, Marcony R.; WILSON, Steven E.; NETTO, Marcelo V.; GHANEN, Ramon C.; MONTEIRO, Mario Luis R.; BECHARA, Samir J.; ESPANA, Edgar M.; MELLO, Glauco R.; KARA-JUNIOR, Newton |
Citation: | JOURNAL OF CATARACT AND REFRACTIVE SURGERY, v.38, n.2, p.215-220, 2012 |
Abstract: | PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add. |
Appears in Collections: | Artigos e Materiais de Revistas Científicas - FM/MOF Artigos e Materiais de Revistas Científicas - HC/ICHC Artigos e Materiais de Revistas Científicas - LIM/33 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
art_SANTHIAGO_Modulation_transfer_function_and_optical_quality_after_bilateral_2012.PDF Restricted Access | publishedVersion (English) | 258.39 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.