Use este identificador para citar ou linkar para este item: https://observatorio.fm.usp.br/handle/OPI/4130
Título: Modulation transfer function and optical quality after bilateral implantation of a+3.00 D versus a+4.00 D multifocal intraocular lens
Autor(es): SANTHIAGO, Marcony R.WILSON, Steven E.NETTO, Marcelo V.GHANEN, Ramon C.MONTEIRO, Mario Luis R.BECHARA, Samir J.ESPANA, Edgar M.MELLO, Glauco R.KARA-JUNIOR, Newton
Parte de: JOURNAL OF CATARACT AND REFRACTIVE SURGERY, v.38, n.2, p.215-220, 2012
Resumo: PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.
Aparece nas coleções:

Artigos e Materiais de Revistas Científicas - FM/MOF
Departamento de Otorrinolaringologia e Oftalmologia - FM/MOF

Artigos e Materiais de Revistas Científicas - HC/ICHC
Instituto Central - HC/ICHC

Artigos e Materiais de Revistas Científicas - LIM/33
LIM/33 - Laboratório de Oftalmologia


Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
art_SANTHIAGO_Modulation_transfer_function_and_optical_quality_after_bilateral_2012.PDF
  Restricted Access
publishedVersion (English)258.39 kBAdobe PDFVisualizar/Abrir    Solicitar uma cópia

Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.