Please use this identifier to cite or link to this item: https://observatorio.fm.usp.br/handle/OPI/47100
Title: Effects of hearing protector devices on speech intelligibility: the importance of individualized assessment
Authors: ROCHA, Clayton H.LISBOA, GabrielaPADILHA, Fernanda Y. O. M. M.RABELO, Camila M.SAMELLI, Alessandra G.
Citation: INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS, v.28, n.2, p.1227-1234, 2022
Abstract: Objectives. This study aimed to compare speech intelligibility in noise with and without hearing protection devices (HPDs). Methods. Fifty-one workers were distributed into three groups: noise-induced hearing loss group (NIHLG), normally hearing noise-exposed group (NG) and normally hearing non-exposed to noise group (CG). A free field system was used to emit monosyllables (65, 70 and 75 dB) and pink noise in different signal-to-noise ratios (SNRs) (0, -5, -10 and -15). Results. In situations with HPDs, all groups showed a decrease in the percentage of correct responses with an increase in noise level. The HPD had little effect on speech intelligibility in the NIHLG and NG. Considering the effect caused by the HPD on speech intelligibility, it was observed that the group with the greatest loss was the CG for SNRs of -5, -10 and -15. Conclusion. Although speech intelligibility is influenced by the hearing threshold, the noise level and SNR are crucial for good speech intelligibility, either with or without an HPD. It is highlighted that the NG had worse results when compared with the CG, which may indicate changes in the auditory pathway resulting from continuous noise exposure, even in the absence of changes in the audiometric thresholds.
Appears in Collections:

Artigos e Materiais de Revistas Científicas - FM/MFT
Departamento de Fisioterapia, Fonoaudiologia e Terapia Ocupacional - FM/MFT

Artigos e Materiais de Revistas Científicas - HC/ICHC
Instituto Central - HC/ICHC

Artigos e Materiais de Revistas Científicas - HU
Hospital Universitário - HU

Artigos e Materiais de Revistas Científicas - LIM/34
LIM/34 - Laboratório de Ciências da Reabilitação


Files in This Item:
File Description SizeFormat 
art_ROCHA_Effects_of_hearing_protector_devices_on_speech_intelligibility_2022.PDF
  Restricted Access
publishedVersion (English)976.29 kBAdobe PDFView/Open Request a copy

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.