SPENCER CHENG

(Fonte: Lattes)
Índice h a partir de 2011
8
Projetos de Pesquisa
Unidades Organizacionais
LIM/26 - Laboratório de Pesquisa em Cirurgia Experimental, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 10 de 26
  • article 24 Citação(ões) na Scopus
    A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis
    (2018) GUEDES, Hugo Goncalo; MOURA, Diogo Turiani Hourneaux de; DUARTE, Ralph Braga; CORDERO, Martin Andres Coronel; SANTOS, Marcos Eduardo Lera dos; CHENG, Spencer; MATUGUMA, Sergio Eiji; CHAVES, Dalton Marques; BERNARDO, Wanderley Marques; MOURA, Eduardo Guimaraes Hourneaux de
    Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 studies were found in the search, among which 4 randomized studies were selected for inclusion in the analysis. A total of 462 patients were evaluated (233: 25G needle/229: 22G needle). The diagnostic sensitivity was 93% for the 25G needle and 91% for the 22G needle. The specificity of the 25G needle was 87%, and that of the 22G needle was 83%. The positive likelihood ratio was 4.57 for the 25G needle and 4.26 for the 22G needle. The area under the sROC curve for the 25G needle was 0.9705, and it was 0.9795 for the 22G needle, with no statistically significant difference between them (p=0.497). Based on randomized studies, this meta-analysis did not demonstrate a significant difference between the 22G and 25G needles used during EUS-FNA in the diagnosis of solid pancreatic lesions.
  • article 11 Citação(ões) na Scopus
    Suction versus slow-pull for endoscopic ultrasound-guided fine-needle aspiration of pancreatic tumors: a prospective randomized trial
    (2020) CHENG, Spencer; BRUNALDI, Vitor O.; MINATA, Mauricio K.; CHACON, Danielle A.; SILVEIRA, Eduardo B.; MOURA, Diogo T. H. de; SANTOS, Marcos E. L. Dos; MATUGUMA, Sergio E.; CHAVES, Dalton M.; FRANCA, Raony F.; JACOMO, Alfredo L.; ARTIFON, Everson L. A.
    Background: Suction (S) is commonly used to improve cell acquisition during endoscopic ultrasoundguided fine-needle aspiration (EUS-FNA). Slow-pull (SP) sampling is another technique that might procure good quality specimens with less bloodiness. We aimed to determine if SP improves the diagnostic yield of EUS-FNA of pancreatic masses. Methods: Patients with pancreatic solid masses were randomized to four needle passes with both techniques in an alternate fashion. Sensitivity, specificity, positive, and negative predictive values were calculated. Cellularity and bloodiness of cytological samples were assessed and compared according to the technique. Results: Sensitivity, specificity, and accuracy of suction vs. SP were 95.2% vs. 92.3%; 100% vs. 100; 95.7% vs. 93%, respectively. As to the association of methods, they were 95.6, 100 and 96%, respectively. Positive predictive values for S and SP were 100%. There was no difference in diagnostic yield between S and SP (p = 0.344). Cellularity of samples obtained with SP and Suction were equivalent in both smear evaluation (p = 0.119) and cell-block (0.980). Bloodiness of SP and suction techniques were similar as well. Conclusions: S and SP techniques provide equivalent sensitivity, specificity, and accuracy. Association of methods seems to improve diagnostic yield. Suction does not increase the bloodiness of samples compared to slow-pull.
  • article 6 Citação(ões) na Scopus
    Natural orifice transluminal endoscopic surgery to salvage a migrated stent during EUS-guided hepaticogastrostomy
    (2016) MOURA, Diogo Turiani Hourneaux De; MESTIERI, Luiz Henrique M.; CHENG, Spencer; RODELA, Gustavo Luis; MOURA, Eduardo Guimaraes Hourneaux De; SAKAI, Paulo; OLIVEIRA, Joel F.; ARTIFON, Everson L.
  • article 1 Citação(ões) na Scopus
    Pure Cut or Endocut for Biliary Sphincterotomy? A Multicenter Randomized Clinical Trial
    (2023) FUNARI, Mateus Pereira; BRUNALDI, Vitor Ottoboni; PROENCA, Igor Mendonca; GOMES, Pedro Victor Aniz; QUEIROZ, Lucas Tobias Almeida; VIEIRA, Yuri Zamban; MATUGUMA, Sergio Eiji; IDE, Edson; FRANZINI, Tomazo Antonio Prince; SANTOS, Marcos Eduardo Lera dos; CHENG, Spencer; MINATA, Mauricio Kazuyoshi; SANTOS, Jose Sebastio dos; MOURA, Diogo Turiani Hourneaux de; KEMP, Rafael; MOURA, Eduardo Guimares Hourneaux de
    INTRODUCTION: Adverse events (AE) after endoscopic retrograde cholangiopancreatography (ERCP) are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger PEP or bleeding. Therefore, this study evaluated the outcomes of 2 electric current modes used during biliary sphincterotomy. METHODS: From October 2019 to August 2021, consecutive patients with native papilla undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation. RESULTS: A total of 550 patients were randomized (272 pure cut and 278 endocut). The overall PEP rate was 4.0% and significantly higher in the endocut group (5.8% vs 2.2%, P = 0.034). Univariate analysis revealed >5 attempts (P = 0.004) and endocut mode (P = 0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (P = 0.005) and a trend for endocut mode as risk factors for PEP (P = 0.052). Intraprocedural bleeding occurred more often with pure cut (P = 0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with endocut (P = 0.047). There was no difference in perforation (P = 1.0) or infection (P = 0.4999) between the groups. DISCUSSION: Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCT assessing the impact of electric current on AE with overlapping preventive measures such as rectal nonsteroidal anti-inflammatory drugs and hyperhydration are needed. The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.
  • article 10 Citação(ões) na Scopus
    Maximizing the Diagnostic Yield of Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy
    (2017) ARTIFON, Everson L. A.; GUEDES, Hugo G.; CHENG, Spencer
  • article 11 Citação(ões) na Scopus
    Papillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial
    (2018) FURUYA, Carlos Kiyoshi; SAKAI, Paulo; MARINHO, Fabio Ramalho Tavares; OTOCH, Jose Pinhata; CHENG, Spencer; PRUDENCIO, Livia Lemes; MOURA, Eduardo Guimaraes Hourneaux de; ARTIFON, Everson Luiz de Almeida
    AIM To compare the cannulation success, biochemical profile, and complications of the papillary fistulotomy technique vs catheter and guidewire standard access. METHODS From July 2010 to May 2017, patients were prospectively randomized into two groups: Cannulation with a catheter and guidewire (Group.) and papillary fistulotomy (Group.). Amylase, lipase and C-reactive protein at T0, as well as 12 h and 24 h after endoscopic retrograde cholangiopancreatography, and complications (pancreatitis, bleeding, perforation) were recorded. RESULTS We included 102 patients (66 females and 36 males, mean age 59.11 +/- 18.7 years). Group. and Group. had 51 patients each. The successful cannulation rates were 76.5% and 100%, respectively (P = 0.0002). Twelve patients (23.5%) in Group. had a difficult cannulation and underwent fistulotomy, which led to successful secondary biliary access (Failure Group). The complication rate was 13.7% (2 perforations and 5 mild pancreatitis) vs 2.0% (1 patient with perforation and pancreatitis) in Groups. and., respectively (P = 0.0597). CONCLUSION Papillary fistulotomy was more effective than guidewire cannulation, and it was associated with a lower profile of amylase and lipase. Complications were similar in both groups.
  • article
    EUS-FNA versus ERCP for tissue diagnosis of suspect malignant biliary strictures: a prospective comparative study
    (2018) MOURA, Diogo Turiani Hourneaux; GUIDAMARAES, Eduardo; MOURA, Hourneaux de; MATUGUMA, Sergio Eiji; SANTOS, Marcos Eduardo dos; MOURA, Eduardo Turiani Hourneaux; BARACAT, Felipe Iankelevich; ARTIFON, Everson L. A.; CHENG, Spencer; BERNARDO, Wanderley Marque; CHACON, Danielle; TANIGAWA, Ryan; JUKEMURA, Jose
    Background and study aims Biliary strictures are frequently a challenging clinical scenario and the anatomopathological diagnosis is essential in the therapeutic management, whether for curative or palliative purposes. The acquisition of specimens is necessary since many benign diseases mimic biliopancreatic neoplasms. Endscopic retrograde cholangiopancreatography (ERCP) is the traditionally used method despite the low sensitivity of biliary brush cytology and forceps biopsy. On the other hand, several studies reported good accuracy rates using endoscopic ultrasound- guided fine-needle aspiration (EUS-FNA). The aim of this prospective study was to compare, the accuracy of EUS-FNA and ERCP for tissue sampling of biliary strictures. Patients and methods After performing the sample size calculation, 50 consecutive patients with indeterminate biliary strictures were included to undergo ERCP and EUS on the same sedation. The gold-standard was surgery or 6 months' follow-up. Evaluation of the diagnostic indices (sensitivity, specificity, positive and negative predictive value, positive and negative likelihood ratio), concordance and adverse events among the methods were performed. Also, subtype analyses of the techniques, anatomical localization and size of the lesion were included. Results The final diagnoses reported in 50 patients were 47 malignant, 1 suspicious and 2 benign lesions. 31 lesions were extraductal and 19 intraductal, 35 were distal and 15 proximal strictures. In the intention-to-treat analysis, the sensitivity and accuracy of EUS-FNA were superior than ERCP tissue sampling (93,8%, 94% vs. 60,4%, 62%, respectively) (P = 0.034), with similar adverse events. There was no concordance between the methods and combining both methods improved the sensitivity and accuracy for 97.9% and 98%, respectively. In the subtype analyses, the EUS-FNA was superior, with a higher accuracy than ERCP tissue sampling in evaluating extraductal lesions (100% vs. 54.8 %, P = 0.019) and in those larger than 1.5 cm (95.8% vs. 61.9%, P = 0.031), but were similar in evaluating intraductal lesions and lesions smaller than 1.5 cm. There was no significant difference between the methods in the analyzes of proximal, distal and pancreatic lesions. Conclusion EUS-FNA is better than ERCP with brush cytology and intraductal forceps biopsy in diagnosing malignant biliary strictures, mainly in the assessment of extraductal lesions and in those larger than 1.5 cm. Combining ERCP with tissue sampling and EUS-FNA is feasible, the techniques have similar complication rates, and the combination greatly improves diagnostic accuracy.
  • article 0 Citação(ões) na Scopus
    The feared postdilation complication in caustic esophageal stenosis: combined endoscopic and surgical treatment
    (2021) SAGAE, Vitor Massaro Takamatsu; RIBEIRO, Igor Braga; PONTE NETO, Alberto Machado da; MATUGUMA, Sergio Eiji; CHENG, Spencer; SANTOS, Marcos Eduardo Lera dos; MOURA, Eduardo Guimaraes Hourneaux de
  • article
    Anti-reflux versus conventional self-expanding metal stents in the palliation of esophageal cancer: A systematic review and meta-analysis
    (2022) SASSO, Joao Guilherme Ribeiro Jordao; MOURA, Diogo Turiani Hourneaux de; PROENCA, Igor Mendonca; MONTE JUNIOR, Epifanio Silvino do; RIBEIRO, Igor Braga; SANCHEZ-LUNA, Sergio A.; CHENG, Spencer; BESTETTI, Alexandre Moraes; KUM, Angelo So Taa; BERNARDO, Wanderley Marques; MOURA, Eduardo Guimaraes Hourneaux de
    Background and study aims Self-expanding metal stents (SEMS) are an effective palliative endoscopic therapy to reduce dysphagia in esophageal cancer. Gastroesophageal reflux disease (GERD) is a relatively common complaint after non-valved conventional SEMS placement. Therefore, valved self-expanding metal stents (SEMS-V) were designed to reduce the rate of GERD symptoms. We aimed to perform a systematic review and meta-analysis comparing the two stents. Material and methods This was a systematic review and meta-analysis including only randomized clinical trials (RCT) comparing the outcomes between SEMS-V and non-valved self-expanding metal stents (SEMS-NV) following the Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines. The risk of bias was assessed using the Cochrane Risk of Bias 2 tool. Data were analyzed with Review Manager Software. Quality of evidence was evaluated using Grading of Recommendations Assessment, Development, and Evaluation guidelines. Results Ten randomized clinical trials including a total of 467 patients, 234 in the SEMS-V group and 233 in the SEMS-NV group, were included. There were no statistically significant differences regarding GERD qualitative analysis (RD -0.17; 95% CI -0.67, 0.33; P= 0.5) and quantitative analysis (SMD -0.22; 95% CI -0.53, 0.08; P=0.15) technical success (RD -0.03; 95% CI -0.07, 0.01; P= 0.16), dysphagia improvement (RD -0.07; 95% CI -0.19, 0.06; P=0.30), and adverse events (RD 0.07; 95% CI -0.07, 0.20; P= 0.32). Conclusions Both SEMS-V and SEMS-NV are safe and effective in the palliation of esophageal cancer with similar rates of GERD, dysphagia relief, technical success, adverse events, stent migration, stent obstruction, bleeding, and improvement of the quality of life.
  • article 8 Citação(ões) na Scopus
    Pancreatitis after endoscopic retrograde cholangiopancreatography: A narrative review
    (2021) RIBEIRO, Igor Braga; MONTE JUNIOR, Epifanio Silvino do; MIRANDA NETO, Antonio Afonso; PROENCA, Igor Mendonca; MOURA, Diogo Turiani Hourneaux de; MINATA, Mauricio Kazuyoshi; IDE, Edson; SANTOS, Marcos Eduardo Lera dos; LUZ, Gustavo de Oliveira; MATUGUMA, Sergio Eiji; CHENG, Spencer; BARACAT, Renato; MOURA, Eduardo Guimaraes Hourneaux de
    Acute post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is a feared and potentially fatal complication that can be as high as up to 30% in high-risk patients. Pre-examination measures, during the examination and after the examination are the key to technical and clinical success with a decrease in adverse events. Several studies have debated on the subject, however, numerous topics remain controversial, such as the effectiveness of prophylactic medications and the amylase dosage time. This review was designed to provide an update on the current scientific evidence regarding PEP available in the literature.