Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases

Carregando...
Imagem de Miniatura
Citações na Scopus
10
Tipo de produção
article
Data de publicação
2011
Título da Revista
ISSN da Revista
Título do Volume
Editora
ELSEVIER SCIENCE INC
Citação
REVISTA BRASILEIRA DE ANESTESIOLOGIA, v.61, n.5, p.610-618, 2011
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
Bliacheriene F, Carmona MJC, Barretti CFM, Haddad CMF, Mouchalwat ES, Bortlotto MRFL, Francisco RPV, Zugaib M - Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases. Background and Objectives: Hemodynamic changes are observed during cesarean section under spinal anesthesia. Non-invasive blood pressure (BP) and heart rate (HR) measurements are performed to diagnose these changes, but they are delayed and inaccurate. Other monitors such as filling pressure and cardiac output (CO) catheters with external calibration are very invasive or inaccurate. The objective of the present study was to report the cardiac output measurements obtained with a minimally invasive uncalibrated monitor (LiDCO rapid) in patients undergoing cesarean section under spinal anesthesia. Case report: After approval by the Ethics Commission, four patients agreed to participate in this study. They underwent cesarean section under spinal anesthesia while at the same time being connected to the LiDCO rapid by a radial artery line. Cardiac output, HR, and BP were recorded at baseline, after spinal anesthesia, after fetal and placental extraction, and after the infusion of oxytocin and metaraminol. We observed a fall in BP with an increase of HR and CO after spinal anesthesia and oxytocin infusion; and an increase in BP with a fall in HR and CO after bolus of the vasopressor. Conclusions: Although this monitor had not been calibrated, it showed a tendency for consistent hemodynamic data in obstetric patients and it may be used as a therapeutic guide or experimental tool.
Palavras-chave
Anesthesia, Spinal, Monitoring, Intraoperative, Hemodynamics, Cardiac Output, Hypotension, Cesarean Section
Referências
  1. Kee WDN, 2004, ANESTH ANALG, V98, P815
  2. Sharwood-Smith G, 2009, BRIT J ANAESTH, V102, P291, DOI 10.1093/bja/aep003
  3. Dyer RA, 2009, ANESTHESIOLOGY, V111, P753, DOI 10.1097/ALN.0b013e3181b437e0
  4. Dyer RA, 2008, ANESTHESIOLOGY, V108, P802, DOI 10.1097/01.anes.0000311153.84687.c7
  5. Tsen LC, 2010, INT J OBSTET ANESTH, V19, P243, DOI 10.1016/j.ijoa.2010.05.001
  6. Langesaeter E, 2008, ANESTHESIOLOGY, V109, P856, DOI 10.1097/ALN.0b013e31818a401f
  7. Archer TL, 2008, INT J OBSTET ANESTH, V17, P247, DOI 10.1016/j.ijoa.2008.03.003
  8. Carvalho JCA, 2004, OBSTET GYNECOL, V104, P1005, DOI 10.1097/01.AOG.0000142709.04450.bd
  9. Hartley H, 2001, INT J OBSTET ANESTH, V10, P182, DOI 10.1054/ijoa.2001.0853
  10. Shibli KU, 2000, INT J OBSTET ANESTH, V9, P160, DOI 10.1054/ijoa.1999.0382
  11. ROBSON SC, 1992, BRIT J ANAESTH, V68, P54, DOI 10.1093/bja/68.1.54
  12. Kee WDN, 2005, ANESTHESIOLOGY, V103, P744, DOI 10.1097/00000542-200510000-00012
  13. Archer TL, 2010, J CLIN ANESTH, V22, P274, DOI 10.1016/j.jclinane.2009.03.019
  14. ROUT CC, 1992, BRIT J ANAESTH, V68, P394, DOI 10.1093/bja/68.4.394
  15. Dyer RA, 2008, ANESTHESIOLOGY, V109, P765, DOI 10.1097/ALN.0b013e31818a3825
  16. Langesafter E, 2008, ANESTHESIOLOGY, V108, P771, DOI 10.1097/ALN.0b013e31816bbe04
  17. Lee SWY, 2009, BRIT J ANAESTH, V103, P457, DOI 10.1093/bja/aep215
  18. Macarthur Alison, 2007, Int Anesthesiol Clin, V45, P115, DOI 10.1097/AIA.0b013e31802b8d53
  19. Vallejo MC, 2003, INT J OBSTET ANESTH, V12, P243, DOI 10.1016/S0959-289X(03)00070-0