Please use this identifier to cite or link to this item: https://observatorio.fm.usp.br/handle/OPI/22469
Title: Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases
Authors: BLIACHERIENE, FernandoCARMONA, Maria Jose CarvalhoBARRETTI, Cristina de Freitas MadeiraHADDAD, Cristiane Maria FedericciMOUCHALWAT, Elaine SoubhiBORTOLOTTO, Maria Rita de Figueiredo LemosFRANCISCO, Rossana Pulcineli VieiraZUGAIB, Marcelo
Citation: REVISTA BRASILEIRA DE ANESTESIOLOGIA, v.61, n.5, p.610-618, 2011
Abstract: Bliacheriene F, Carmona MJC, Barretti CFM, Haddad CMF, Mouchalwat ES, Bortlotto MRFL, Francisco RPV, Zugaib M - Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases. Background and Objectives: Hemodynamic changes are observed during cesarean section under spinal anesthesia. Non-invasive blood pressure (BP) and heart rate (HR) measurements are performed to diagnose these changes, but they are delayed and inaccurate. Other monitors such as filling pressure and cardiac output (CO) catheters with external calibration are very invasive or inaccurate. The objective of the present study was to report the cardiac output measurements obtained with a minimally invasive uncalibrated monitor (LiDCO rapid) in patients undergoing cesarean section under spinal anesthesia. Case report: After approval by the Ethics Commission, four patients agreed to participate in this study. They underwent cesarean section under spinal anesthesia while at the same time being connected to the LiDCO rapid by a radial artery line. Cardiac output, HR, and BP were recorded at baseline, after spinal anesthesia, after fetal and placental extraction, and after the infusion of oxytocin and metaraminol. We observed a fall in BP with an increase of HR and CO after spinal anesthesia and oxytocin infusion; and an increase in BP with a fall in HR and CO after bolus of the vasopressor. Conclusions: Although this monitor had not been calibrated, it showed a tendency for consistent hemodynamic data in obstetric patients and it may be used as a therapeutic guide or experimental tool.
Appears in Collections:

Artigos e Materiais de Revistas Científicas - FM/MCG
Departamento de Cirurgia - FM/MCG

Artigos e Materiais de Revistas Científicas - FM/MOG
Departamento de Obstetrícia e Ginecologia - FM/MOG

Artigos e Materiais de Revistas Científicas - HC/ICHC
Instituto Central - HC/ICHC

Artigos e Materiais de Revistas Científicas - HC/InCor
Instituto do Coração - HC/InCor

Artigos e Materiais de Revistas Científicas - LIM/08
LIM/08 - Laboratório de Anestesiologia

Artigos e Materiais de Revistas Científicas - LIM/57
LIM/57 - Laboratório de Fisiologia Obstétrica


Files in This Item:
File Description SizeFormat 
art_BLIACHERIENE_Use_of_a_Minimally_Invasive_Uncalibrated_Cardiac_Output_2011.PDFpublishedVersion (English)286.51 kBAdobe PDFThumbnail
View/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.