FABIO YUJI HONDO

(Fonte: Lattes)
Índice h a partir de 2011
6
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina - Médico
Instituto do Câncer do Estado de São Paulo, Hospital das Clínicas, Faculdade de Medicina - Médico

Resultados de Busca

Agora exibindo 1 - 9 de 9
  • conferenceObject
    Endoscopic Papillary Large Balloon Dilation Associated With Sphincterotomy for Extraction of Large Bile Duct Stones
    (2012) LUZ, Gustavo O.; MOURA, Eduardo G. De; MEINE, Gilmara C.; CARNEIRO, Fred O.; MEDRADO, Bruno F.; ALMEIDA, Maira R.; MALUF-FILHO, Fauze; LERA, Marcos; IDE, Edson; FURUYA, Carlos K.; CHAVES, Dalton M.; CHENG, Spencer; MATUGUMA, Sergio E.; TOMISHIGE, Toshiro; HONDO, Fabio Y.; BARACAT, Renato; ARTIFON, Everson L.; FRANZINI, Tomazo; SAKAI, Paulo
    Common bile duct stones larger than 15mm are related to a higher rate of failure of endoscopic ductal clearance and need for mechanical lithotripsy. Recently, endoscopic papillary large balloon dilation (EPLBD) associated with endoscopic sphyncterotomy (ES) has been advocated for the management of difficult bile duct stones. Objective: Evaluate the efficacy and safety of EPLBD associated with ES for removal of large bile duct stones. Patients and methods: retrospective review of prospectively collected data in an academic tertiary referral center, from November 2009 to August 2011. Ampullary dilation was performed with a wire guided hydrostatic balloon (CRE/Boston Scientific) which size ranged from 12 to 20mm. The stone size and the duct diameter directed the choice of the balloon diameter. Balloon was inflated with diluted contrast medium under endoscopic and fluoroscopic control until waist disappearance and/or maximal balloon pressure. After dilation stones were extracted with the aid of standard accessories and techniques. Outcomes and adverse events were recorded. Results: A total of 730 patients with common bile duct stones were admitted for ERCP in our institution. 123 (16,8%) patients were submitted to EPLBD after sphincterotomy. The mean age was 56 years (22-98) and 77 were female (63%). The size of the stones ranged from 13 to 30mm. Initial procedure success rate without mechanical lithitripsy was 83% (102/123). In further 4 patients (3,2%) mechanical lithotripsy was used with 75% success rate (3/4). For the remaining 17 patients, mechanical litotripsy was not available and a 10Fr biliary stent was introduced to prevent obstruction and cholangitis. The total adverse events rate was 3,2%. There were 2 cases of perforation with 20mm balloon (1,6%), both treated conservatively, and two cases of mild acute pancreatitis (1,6%). None of the patients presented bleeding that required transfusion or hospitalization. Conclusion: EPLBD after sphincterotomy is a safe and effective technique for the management of large bile duct stones and it avoids mechanical lithotripsy in the majority of cases.
  • article 4 Citação(ões) na Scopus
    PEG rescue with gastropexy after early tube withdrawal: an application of natural orifice transluminal endoscopic surgery (with video)
    (2011) MARTINS, Bruno da Costa; TAKADA, Jonas; KAWAGUTI, Fabio Shiguehissa; RIBEIRO, Joao Paulo Aguiar; HONDO, Fabio Yuji; LIMA, Marcelo Simas de; NEVES, Carla Zanellatto; NAHAS, Caio Sergio R.; MARQUES, Carlos Frederico Sparapan; SAKAI, Paulo; MALUF-FILHO, Fauze
  • article 3 Citação(ões) na Scopus
    OCULAR MELANOMA WITH MULTIPLE GASTROINTESTINAL METASTASES
    (2011) KAWAGUTI, Fabio Shiguehissa; MALUF-FILHO, Fauze; MEDEIROS, Raphael Salles S.; MARTINS, Bruno Da Costa; LIMA, Marcelo Simas De; HONDO, Fabio Yuji; NAHAS, Caio Sergio Rizkallah; MARQUES, Carlos Frederico Sparapan; SAKAI, Paulo
  • article 11 Citação(ões) na Scopus
    A new large-caliber trocar for percutaneous endoscopic gastrostomy by the introducer technique in head and neck cancer patients
    (2011) GIORDANO-NAPPI, J. H.; MALUF-FILHO, F.; ISHIOKA, S.; HONDO, F. Y.; MATUGUMA, S. E.; LIMA, M. Simas de; SANTOS, M. Lera dos; RETES, F. A.; SAKAI, P.
    Background and study aims In many patients, percutaneous endoscopic gastrostomy (PEG) can be limited by digestive tract stenosis. PEG placement using an introducer is the safest alternative for this group of patients, but the available devices are difficult to implement and require smaller-caliber tubes. The aim of this study was to evaluate the modification of an introducer technique device for PEG placement with regard to the following: procedure feasibility, possibility of using a 20-Fr balloon gastrostomy tube, tube-related function and problems, complications, procedure safety, and mortality. Patients and methods Between March 2007 and February 2008, 30 consecutive patients with head and neck malignancies underwent introducer PEG placement with the modified device and gastropexy. Each patient was evaluated for 60 days after the procedure for the success of the procedure, infection, pain, complications, mortality, and problems with the procedure. Results The procedure was successful in all cases with no perioperative complications. No signs of stomal infection were observed using the combined infection score. The majority of patients experienced mild-to-moderate pain both in the immediate postoperative period and at 72 hours. One major early complication (3.3%) and two minor complications (6.7%) were observed. No procedure-related deaths occurred during the first 60 days after the procedure. Conclusion The device modification for PEG using the introducer technique is feasible, safe, and efficient in outpatients with obstructive head and neck cancer. In this series, it allowed the use of a larger-caliber tube with low complication rates and no procedure-related mortality.
  • bookPart
    Divertículos esofágicos e faringoesofágicos
    (2013) UEMURA, Ricardo Sato; HONDO, Fábio Yuji; SAKAI, Paulo
  • article 1 Citação(ões) na Scopus
    Comparison of electrical current and ultrasonic device for incision of the septum of the pharyngoesophageal diverticulum in a pig model
    (2015) HONDO, Fabio Yuji; GIORDANO-NAPPI, Jose Humberto; PESSORRUSSO, Fernanda Cristina Simoes; FRANCO, Matheus Cavalcante; NEVES, Carla Zanelatto; CECCONELLO, Ivan; SAKAI, Paulo; MALUF-FILHO, Fauze
    Complications of endoscopic treatment of pharyngoesophageal diverticulum (PED) such as bleeding and perforation occur in up to 15 % of cases. Our objective was to compare incision of the PED septum using the ultrasonic device (group H) with incision using electrical current (group M) in a pig model. Twenty domestic pigs were divided into groups H and M. The incision of the PED septum was performed using the ultrasonic device or using electrical current, respectively. The procedural time, complication rate, length of the border of the incised septum, and thermal tissue damage were compared between groups. Mean time to divide the septum and total procedure time were significantly shorter in group H. Mean length of the border of the incised septum was significantly higher in group H. The lateral thermal spread caused by electrical current (group M) was more intense. Hemorrhage was exclusively observed in group M. Experimental endoscopic diverticulotomy using ultrasonic device was faster and caused less tissue damage when compared to electrical current.
  • article 0 Citação(ões) na Scopus
    IMPROVED EXPERIMENTAL MODEL TO EVALUATE SUBMUCOSAL INJECTION SOLUTIONS FOR ENDOSCOPIC SUBMUCOSAL DISSECTION
    (2015) YAMAZAKI, Kendi; MALUF-FILHO, Fauze; COSTA, Vitor Alves Pessoa da; PESSORRUSSO, Fernanda Cristina Simões; HONDO, Fabio Yuji; SAKAI, Paulo; FIGUEIREDO, Luis Francisco Poli de
    Background: Endoscopic submucosal dissection carries an increased risk of bleeding and perforation. The creation of a long lasting submucosal cushion is essential for the safe and complete removal of the lesion. There is not a suitable experimental model for evaluation of the durability of the cushioning effect of different solutions. Aim: To describe an improved experimental model to evaluate submucosal injection solutions. Methods: A total of four domestic pigs were employed to evaluate two different submucosal fluid solutions in the gastric submucosa. After midline laparotomy, the anterior gastric wall was incised from the gastric body to the antrum and its mucosal surface was exposed by flipping inside out the incised gastric wall. Two different solutions (10% mannitol and normal saline) were injected in the submucosa of the anterior wall of the distal gastric body. All submucosal cushions were injected until they reach the same size, standardized as 1.0 cm in height and 2.0 cm in diameter. A caliper and a ruler were employed to guarantee accuracy of the measurements. Results: All four animal experiments were completed. All submucosal cushions had the exact same size measured with caliper and a ruler. By using the mannitol solution, the mean duration of the submucosal cushion was longer than the saline solution: 20 and 22 min (mean, 21 min) vs 5 and 6 min (mean, 5.5 min) Conclusions: This experimental model is simple and evaluate the duration, size, and effect of the submucosal cushion, making it more reliable than other models that employ resected porcine stomachs or endoscopic images in live porcine models.
  • article 34 Citação(ões) na Scopus
    Endoscopic treatment of Zenker's diyerticulum by harmonic scalpel
    (2011) HONDO, Fabio Yuji; MALUF-FILHO, Fauze; GIORDANO-NAPPI, Jose Humberto; NEVES, Carla Zanelatto; CECCONELLO, Ivan; SAKAI, Paulo
    Background: Zenker's diverticulum (ZD) is a rare condition with a reported prevalence of 0.01% to 0.11% in the general population. Endoscopic treatment consists of the division of the septum between the diverticulum and the esophagus, within which the cricopharyngeal muscle is contained. Diathermic monopolar current, argon plasma coagulation, and laser have been used to incise the muscular septum with satisfactory results. The main limitation of endoscopic treatment is the occurrence of complications. Perforation and hemorrhage are reported in as many as 23% and 10% of patients, respectively. Objective: The aim of this study was to use the technique of endoscopic diverticulotomy by using a harmonic scalpel in patients with ZD and to demonstrate the feasibility of using flexible and rigid devices in ZD treatment. Design: Case series study. Standard protocol was used for patient management, endoscopic procedure, and data collection. Setting: Single endoscopist demonstrating preliminary results. Patients: Five patients (4 men; median standard deviation [SD] age 69.6 +/- 9.06 years, range 59-83 years) with ZD were treated with this technique. All patients reported dysphagia and halitosis. The diagnosis was based on clinical, endoscopic, and radiographic findings. Interventions: All patients received general anesthesia and were placed in the left lateral position. A standard videogastroscope (9.8 mm) and a stiff guidewire were used to insert and achieve an adequate exposure of the ZD septum. The septum was divided using a harmonic scalpel under thin endoscope (5.2 mm) visualization through a soft diverticuloscope. Main Outcome Measurement: Feasibility of an endoscopic technique by using rigid and flexible devices to treat ZD. Results: Four patients (80%) were successfully treated in 1 session. The median SD size of the diverticulum was 3.6 +/- 0.89 cm (range 3-5 cm). Median SD procedure time was 17.33 +/- 2.33 minutes (range 15-20 minutes) in 6 procedures. No hemorrhage or perforation occurred. One patient (20%) required a second session to complete dissection of the ZD septum. All patients demonstrated improvement of dysphagia score after treatment. Limitations: Small case series design. Conclusions: Endoscopic treatment of ZD by harmonic scalpel through a soft diverticuloscope was feasible and effective in this small case series. Larger studies are warranted to further evaluate this technique.
  • bookPart
    Tratamento endoscópico do divertículo de Zenker 315
    (2014) HONDO, Fabio Yuji; OLIVEIRA, Luciana Lopes de; MELO, Jeane Martins; SAKAI, Paulo; ARTIFON, Everson Luiz de Almeida