ANA CRISTINA HIROMI HOSHINO

Índice h a partir de 2011
5
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • article
    Evolução audiométrica em usuários de implante coclear multicanal
    (2013) HOSHINO, Ana Cristina Hiromi; CRUZ, Dorilan Rodriguez da; GOFFI-GOMEZ, Maria Valéria Schmidt; BEFI-LOPES, Débora Maria; MATAS, Carla Gentile; FORTUNATO-TAVARES, Talita M.; TSUJI, Robinson Koji
    PURPOSE: to evaluate how long after activation one can achieve the desired auditory thresholds in individuals multichannel cochlear implant users from different age groups. METHOD: a retrospective cross-sectional from a database, approved by CEP / FMUSP, under number 779/06. Individuals implanted between January 2005 and September 2008, whose files had preoperative audiometric data and 3, 6 and 12 months after CI were included. Seventy-two patients fulfilled the criteria, and they were divided in two groups according to age: group I (17 year old) and GII (18-66 year old). Analysis of variance (ANOVA) of one factor in order to verify the interaction between the mean threshold and time after CI were used. RESULTS: we observed that 15 of the GI have reached around 30dBNA thresholds at 3 months after implant. The same happened to 26 patients of GII. We found significant interaction between time (F (3.140) = 91.973, p = 0.00) and the average hearing thresholds. Post-hoc analysis in the GI group were statistically significant differences for comparisons between HA and 3 months after implantation (p = 0.00) and between 3 and 12 months (p = 0.28). For GII only for comparison between HA and 3 months (p = 0.00). CONCLUSION: a significant hearing change may be observed beginning from three months after IC, but this result is not found in all implanted subjects.
  • article 5 Citação(ões) na Scopus
    Converted and Upgraded Maps Programmed in the Newer Speech Processor for the First Generation of Multichannel Cochlear Implant
    (2013) MAGALHAES, Ana Tereza de Matos; GOFFI-GOMEZ, M. Valeria Schmidt; HOSHINO, Ana Cristina; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira; BRITO, Rubens
    Objective: To identify the technological contributions of the newer version of speech processor to the first generation of multichannel cochlear implant and the satisfaction of users of the new technology. Among the new features available, we focused on the effect of the frequency allocation table, the T-SPL and C-SPL, and the preprocessing gain adjustments (adaptive dynamic range optimization). Study Design: Prospective exploratory study. Setting: Cochlear implant center at hospital. Patients: Cochlear implant users of the Spectra processor with speech recognition in closed set. Seventeen patients were selected between the ages of 15 and 82 and deployed for more than 8 years. Interventions: The technology update of the speech processor for the Nucleus 22. Main Outcome Measures: To determine Freedom's contribution, thresholds and speech perception tests were performed with the last map used with the Spectra and the maps created for Freedom. To identify the effect of the frequency allocation table, both upgraded and converted maps were programmed. One map was programmed with 25dB T-SPL and 65dB C-SPL and the other map with adaptive dynamic range optimization. To assess satisfaction, SADL and APHAB were used. Results: All speech perception tests and all sound field thresholds were statistically better with the new speech processor; 64.7% of patients preferred maintaining the same frequency table that was suggested for the older processor. The sound field threshold was statistically significant at 500, 1,000, 1,500, and 2,000 Hz with 25dB T-SPL/65dB C-SPL. Regarding patient's satisfaction, there was a statistically significant improvement, only in the subscale of speech in noise abilities and phone use. Conclusion: The new technology improved the performance of patients with the first generation of multichannel cochlear implant.