  • article 11 Citação(ões) na Scopus
    A new large-caliber trocar for percutaneous endoscopic gastrostomy by the introducer technique in head and neck cancer patients
    (2011) GIORDANO-NAPPI, J. H.; MALUF-FILHO, F.; ISHIOKA, S.; HONDO, F. Y.; MATUGUMA, S. E.; LIMA, M. Simas de; SANTOS, M. Lera dos; RETES, F. A.; SAKAI, P.
    Background and study aims In many patients, percutaneous endoscopic gastrostomy (PEG) can be limited by digestive tract stenosis. PEG placement using an introducer is the safest alternative for this group of patients, but the available devices are difficult to implement and require smaller-caliber tubes. The aim of this study was to evaluate the modification of an introducer technique device for PEG placement with regard to the following: procedure feasibility, possibility of using a 20-Fr balloon gastrostomy tube, tube-related function and problems, complications, procedure safety, and mortality. Patients and methods Between March 2007 and February 2008, 30 consecutive patients with head and neck malignancies underwent introducer PEG placement with the modified device and gastropexy. Each patient was evaluated for 60 days after the procedure for the success of the procedure, infection, pain, complications, mortality, and problems with the procedure. Results The procedure was successful in all cases with no perioperative complications. No signs of stomal infection were observed using the combined infection score. The majority of patients experienced mild-to-moderate pain both in the immediate postoperative period and at 72 hours. One major early complication (3.3%) and two minor complications (6.7%) were observed. No procedure-related deaths occurred during the first 60 days after the procedure. Conclusion The device modification for PEG using the introducer technique is feasible, safe, and efficient in outpatients with obstructive head and neck cancer. In this series, it allowed the use of a larger-caliber tube with low complication rates and no procedure-related mortality.
  • article 35 Citação(ões) na Scopus
    Narrow-band imaging without magnification for detecting early esophageal squamous cell carcinoma
    (2011) IDE, Edson; MALUF-FILHO, Fauze; CHAVES, Dalton Marques; MATUGUMA, Sergio Eiji; SAKAI, Paulo
    AIM: To compare narrow-band imaging (NBI) without image magnification, and chromoendoscopy with Lugol's solution for detecting high-grade dysplasia and intramucosal esophageal squamous cell carcinoma (SCC) in patients with head and neck cancer. METHODS: This was a prospective observational study of 129 patients with primary head and neck tumors consecutively referred to the Gastrointestinal Endoscopy Unit of Hospital das Clinicas, Sao Paulo University Medical School, Brazil, between August 2006 and February 2007. Conventional examinations with NBI and Lugol chromoendoscopy were consecutively performed, and the discovered lesions were mapped, recorded and sent for biopsy. The results of the three methods were compared regarding sensitivity, specificity, accuracy, positive predictive value, negative predictive value, positive likelihood value and negative likelihood value. RESULTS: Of the 129 patients, nine (7%) were diagnosed with SCC, 5 of which were in situ and 4 which were intramucosal. All carcinomas were detected through NBI and Lugol chromoendoscopy. Only 4 lesions were diagnosed through conventional examination, all of which were larger than 10 mm. CONCLUSION: NBI technology with optical filters has high sensitivity and high negative predictive value for detecting superficial esophageal SCC, and produces results comparable to those obtained with 2.5% Lugol chromoendoscopy.