ALEXANDRE SADAO IUTAKA

Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais
Instituto de Ortopedia e Traumatologia, Hospital das Clínicas, Faculdade de Medicina - Médico
LIM/41 - Laboratório de Investigação Médica do Sistema Músculoesquelético, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • article 26 Citação(ões) na Scopus
    Feasibility of Intralaminar, Lateral Mass, or Pedicle Axis Vertebra Screws in Children Under 10 Years of Age: A Tomographic Study
    (2012) CRISTANTE, Alexandre Fogaca; TORELLI, Alessandro Gonzalez; KOHLMANN, Rafael Bellucci; ROCHA, Ivan Dias da; BIRAGHI, Olavo Letaif; IUTAKA, Alexandre Sadao; MARCON, Raphael Martus; OLIVEIRA, Reginaldo Perilo; BARROS FILHO, Tarcisio Eloy Pessoa de
    BACKGROUND: There are several techniques for screw insertion in upper cervical spine surgery, and the use of the 3.5-mm screw is usually the standard. However, there is no consensus regarding the feasibility of using these screws in the pediatric population. OBJECTIVE: To determine the measurement of the lamina angle, lamina and pedicle length and thickness, and lateral mass length of the topographic axial view of the axis vertebra of 2- to 10-year-old children to guide the use of surgical screws. METHODS: Seventy-five computed tomography scans from 24- to 120-month-old patients were studied. Measurements were taken in an axial view of C2 and correlated with 2 age groups and both sexes. Statistical analysis was performed with the Student t test. RESULTS: In the 24- to 48-month age group, only 5.5% of the lamina and 8.3% of the pedicles had thicknesses < 3.5 mm. In the 49- to 120-month age group, there were no lamina thickness values < 3.5 mm, and 1.2% of pedicle thicknesses were < 3.5 mm. Both age groups had no lamina and pedicle lengths < 12 mm and no lateral mass lengths > 12 mm. CONCLUSION: In the majority of cases, the use of 3.5-mm lamina and pedicle screws in children is feasible. A base value of 45 degrees for the spinolaminar angle can be adopted as a reference for insertion of screws in the C2 lamina. This information can be particularly useful for decision making during preoperative planning for C1-C2 or craniocervical arthrodesis in children.
  • article 5 Citação(ões) na Scopus
    TOMOGRAPHIC ANALYSIS OF ANATOMICAL PARAMETERS OF THE AXIS IN CHILDREN
    (2012) TORELLI, Alessandro Gonzalez; KOHLMANN, Rafael Bellucci; BIRAGHI, Olavo Letaif; LUTAKA, Alexandre Sadao; CRISTANTE, Alexandre Fogaca; MARCON, Raphael Martus
    Objective: To carry out an anatomical study of the axis with the use of computed tomography (CT) in children aged from two to ten years, measuring the lamina angle, lamina and pedicle length and thickness, and lateral mass length. Methods: Sixty-four CTs were studied from patients aged 24 to 120 months old, of both sexes and without any cervical anomaly. The measurements obtained were correlated with the data on age and sex of the patients. Statistical analysis was performed using the Students ""t"" tests. Results: We found that within the age range 24-48 months, 5.5% of the lamina and 8.3% of the pedicles had thicknesses of less than 3.5mm, which is the minimum thickness needed for insertion of the screw. Between 49 and 120 months, there were no lamina thicknesses of less than 3.5mm, and 1.2% of the pedicle thicknesses were less than 3.5mm values. Neither of the age groups had any lamina and pedicle lengths of less than 12mm, or lateral mass lengths greater than 12mm. Conclusion: The analysis of the data obtained demonstrates that most of the time, is possible to use a 3.5mm pedicle screw in the laminas and pedicles of the axis in children. Level of Evidence: II, Development of diagnostic criteria in consecutive patients.