RODRIGO CAñADA TROFO SURJAN

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/37 - Laboratório de Transplante e Cirurgia de Fígado, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • article 0 Citação(ões) na Scopus
    First description of extended and tailored fluorescence-guided lymphadenectomy during robotic distal pancreatosplenectomy: case report
    (2023) SURJAN, R. C. T.; SILVEIRA, S. P.; FIGUEIRA, E. R. R.; ARDENGH, J. C.
    Background: Minimally invasive distal pancreatosplenectomies for the treatment of pancreatic duct adenocarcinoma (PDAC) of the pancreatic body have become a well-established approach. To improve oncologic resection and lymph node (LN) dissection, technical alternatives have emerged on the last few years, such as the radical antegrade modular pancreatosplenectomy (RAMPS). While it is accepted that 12 LNs should be retrieved during distal pancreatosplenectomies, during RAMPS procedure the mean harvest is described to be 21 LNs (range, 11–30). With the objective of performing extended and tailored lymphadenectomies during robotic distal pancreatosplenectomies, we developed a novel technique for LN dissection with the use of real-time near-infrared robotic fluorescence and direct injection of indocyanine green in the pancreas as a contrast agent. Case Description: The patient presented pathologically confirmed PDAC on the body of the pancreas and was submitted to totally robotic distal pancreatosplenectomy. After exposing the pancreatic body and under intraoperative sonography guidance, 1 mL of indocyanine green was injected on the pancreas just proximal to the tumor. Using robotic fluorescence, we could clearly identify the lymphatic drainage of the pancreatic body, in order to perform fluorescence-guided, extended and tailored lymphadenectomy. Operative time was 4 hours and 43 minutes. Forty-three LNs were retrieved. Surgical margin was free from neoplasia. Postoperative period was uneventful. Conclusions: Fluorescence-guided extended lymphadenectomy with intrapancreatic injection of indocyanine green is a novel technique that may improve oncological results and staging during robotic distal pancreatosplenectomies for the treatment of PDAC of the pancreatic body.
  • article
    Endoscopic Ultrasound-Guided Tissue Acquisition Versus Fine Needle Aspiration for Diagnosis of Pancreatic Ductal Adenocarcinoma
    (2023) OMAIRI, Tarik W.; MICELLI-NETO, Otavio; TAGLIERI, Eloy; ARAUJO-FILHO, Jesse C. de; FARIA, Andressa Tome R. de; GOLDMAN, Suzan M.; SURJAN, Rodrigo Canada T.; MACHADO, Marcel A.; VENCO, Filadelfio E.; ARDENGH, Jose C.
    Objectives: Compare the 22G needle versus EchoTip ProCore & REG; 20 (Cook Medical, Bloomington, IN, USA) on their handling, specimen suitability, amount of tissue obtained, diagnostic performance, the possibility of immunohistochemistry, and rate of adverse events. Materials and methods: This is a retrospective, comparative study of consecutively examined patients with pancreatic masses who underwent endosonography-guided fine needle aspiration (FNA) via the 22G needle, and endosonography-guided tissue acquisition (TA) via ProCore 20 (PC20). The operator evaluated needle insertion and subjectively classified the specimen. The pathologist measured the samples, classified the amount of tissue, and determined the influence of bleeding on the interpretation. Results: A total of 129 patients participated in the study, out of whom 52 underwent endosonographyguided FNA with 22G and 77 underwent endosonography-guided TA with a PC20 needle. Malignant lesions were found in 106, and 23 had benign lesions. The duodenal route was used in 62% of patients. The 22G needle was easier to introduce (p=0.0495). However, PC20 obtained a larger amount (p<0.01) with fewer punctures (p<0.001). The PC20 also yielded a larger average microcore diameter (p=0.0032). Microhistology was adequate for 22G and PC20 in 22 (42.2%) and 50 (78.1%) specimens, respectively (p<0.001). Bleeding was not significantly different (p>0.999). Immunohistochemistry was possible in 36 (69.2%) and 40 (51.9%) specimens obtained by 22G and PC20, respectively (p=0.075). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 22G were 93.5%, 100%, 100%, 66.7%, and 94.2%, respectively; and for PC20, it was 95%, 100%, 100%, 85%, and 96.1%, respectively. Mild bleeding was the most common early adverse event, occurring in 2/52 (3.8%) 22G and 4/77 (5.2%) PC20 cases (p>0.05). Conclusions: The PC20 required fewer punctures and reduced the need for immunohistochemistry as it yielded better and larger microcores. Its ease of insertion into the target lesion makes it a good option to obtain satisfactory microcore specimens in difficult positions, such as the transduodenal route.
  • article
    First Robotic Roux-en-Y Gastric Bypass for the Treatment of Refractory Gastroesophageal Reflux Disease in a Patient With Systemic Sclerosis
    (2023) SURJAN, Rodrigo Canada T.; SILVEIRA, Sergio; FIGUEIRA, Estela R.
    Systemic sclerosis (SSc) is an immune-mediated disease that results in fibrosis of the skin and internal organs. Refractory gastroesophageal reflux disease (GERD) associated with severe esophageal dysmotility is common in SSc patients, and surgical treatment with usual anti-reflux procedures such as fundoplications is associated with dismal symptomatic relief and postoperative dysphagia. We report the first robotic short -limb Roux-en-Y gastric bypass (RYGB) with a short Roux limb for the treatment of GERD in a patient with SSc with intense esophageal dysmotility. The operative time was two hours. The procedure and postoperative course were uneventful. The patient presented complete relief of gastroesophageal reflux symptoms and no postoperative dysphagia in a two-year follow-up. Therefore, short-limb RYGB is a safe and very effective alternative for the treatment of severe GERD in patients with SSc. The robotic surgical platform may have some advantages compared to conventional laparoscopy.