RODRIGO CAñADA TROFO SURJAN

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/37 - Laboratório de Transplante e Cirurgia de Fígado, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • article
    LAPAROSCOPIC UNCINATECTOMY: A MORE CONSERVATIVE APPROACH TO THE UNCINATE PROCESS OF THE PANCREAS
    (2017) SURJAN, Rodrigo Cañada; BASSERES, Tiago; MAKDISSI, Fabio Ferrari; MACHADO, Marcel Autran Cesar; ARDENGH, José Celso
    ABSTRACT Background: The isolate resection of the uncinate process of the pancreas is a rarely described procedure but is an adequate surgery to treat benign and low grade malignancies of the uncinate process of the pancreas. Aim: To detail laparoscopic uncinatectomy technique and present the initial results. Method: Patient is placed in supine position with the surgeon between legs. Three 5-mm, one 10-mm and one 12-mm trocars were used to perform the isolated resection of the uncinate process of the pancreas. Parenchymal transection is performed with harmonic scalpel. A hemostatic absorbable tissue is deployed over the area previously occupied by the uncinate process. A Waterman drain is placed. Result: This procedure was applied to an asymptomatic 62-year-old male with biopsy proven low grade neuroendocrine tumor of the pancreatic uncinate process. A laparoscopic pancreaticoduodenectomy was proposed. During the initial surgical evaluation, intraoperative sonography was performed and disclosed that the lesion was a few millimeters away from the Wirsung. The option was to perform a laparoscopic uncinatectomy. Postoperative period until full recovery was swift and uneventful. Conclusion: Laparoscopic uncinatectomy is a safe and efficient procedure when performed by surgical teams with large experience in minimally invasive biliopancreatic procedures.
  • article 3 Citação(ões) na Scopus
    Single-port for laparoscopic gastric resection with a novel platform
    (2014) MACHADO, Marcel Autran; MAKDISSI, Fabio F.; SURJAN, Rodrigo C.
    INTRODUCTION: Laparoscopic gastrointestinal resections using single-port are possible, but triangulation problems and the need of articulated instruments difficult the procedures. AIM: To present a surgical alternative using single-port laparoscopic device on gastric resection. TECHNIQUE: The patient is placed in a supine and reverse Trendelenburg position with surgeon between patient's legs. First assistant was on the right side of the patient with the monitor placed on the patient's cranial side. With the patient under general anesthesia, a transumbilical 3 cm skin incision is performed. A single-incision advanced access platform with gelatin cap, self-retaining sleeve and wound protector is introduced through this incision. Three 5-12 mm operating ports were introduced through the single-port device. Due to the gel cap and sleeves, no articulated instruments are necessary. CO2 pneumoperitoneum is established at 12 mmHg. A rigid 30 degree 10 mm laparoscope is introduced. Operation begins with access to the lesser sac by opening the omentum along the greater curvature of the stomach using harmonic scalpel. Once the stomach is fully exposed and a stay suture is place around the tumor. Gastric wall is divided with cautery 1 cm away from the tumor. Tumor is excised. Gastric wall is sutured with two-layer running suture. No drain was used. Umbilical incision was closed. RESULTS: This procedure was used in one patient with gastric duplication. Operative time was 200 minutes. Blood loss was minimal. Recovery was uneventful and patient discharged on postoperative day 2. Final aspect of the umbilical incision was good. CONCLUSIONS: Gastric resection with single-port laparoscopic platform is feasible and may be safely performed in selected patients.
  • article 12 Citação(ões) na Scopus
    Anatomical basis for the intrahepatic glissonian approach during hepatectomies
    (2015) SURJAN, Rodrigo Cañada Trofo; MAKDISSI, Fábio Ferrari; MACHADO, Marcel Autran Cesar
    BACKGROUND: Anatomical liver resections are based on some basic technical principles such as vascular control, ischemic area delineation to be resected and maximum parenchymal preservation. These aspects are achieved by the intrahepatic glissonian approach, which consists in accessing the pedicles of hepatic segments within the hepatic parenchyma. Small incisions on well-defined anatomical landmarks are performed to approach the pedicles, making dissection of the hilar plate unnecessary. AIM: Analyze parameters in liver anatomy related to intrahepatic surgical technique to glissonians pedicles, to set the normal anatomy related to the procedure and thereby facilitate the attainment of this technique. METHODS: Anatomical parameters related to the intrahepatic glissonian approach were studied in 37 cadavers. Measurements were performed with precision instruments. Data were expressed as mean±standard deviation. The subjects were divided into groups according to gender and liver weight and groups were compared statistically. RESULTS: Twenty-five cadavers were male and 12 female. No statistically significant difference was observed in virtually all parameters when groups were compared. This demonstrates the consistency of the anatomical parameters related to the intrahepatic glissonian approach. CONCLUSION: The results obtained in this study made possible major technical advances in the realization of open and laparoscopic hepatectomies with intrahepatic glissonian approach, and can help surgeons to perform liver resections by this method.