LUCY SANTOS VILAS BOAS

(Fonte: Lattes)
Índice h a partir de 2011
16
Projetos de Pesquisa
Unidades Organizacionais
LIM/52 - Laboratório de Virologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 10 de 13
  • conferenceObject
    SARS-CoV-2 Aerosol Generation During Respiratory Equipment Reprocessing
    (2021) BRUNA, Camila Quartim de Moraes; CIOFI-SILVA, Caroline; GRAZIANO, Kazuko Uchikawa; MENDES-CORREA, Maria Cassia; BOAS, Lucy Santos Villas; FERREIRA, Noeli Evangelista; TOZETTO-MENDOZA, Tania; PAULA, Anderson Vicente de
  • article 0 Citação(ões) na Scopus
    Evaluation of enterovirus concentration, species identification, and cerebrospinal fluid parameters in patients of different ages with aseptic meningitis in Sao Paulo, Brazil
    (2024) HONORATO, Layla; FERREIRA, Noely Evangelista; DOMINGUES, Renan Barros; SENNE, Carlos; LEITE, Fernando Brunale Vilela de Moura; SANTOS, Marcio Vega dos; FERNANDES, Gustavo Bruniera Peres; PAIAO, Heuder Gustavo Oliveira; BOAS, Lucy Santos Vilas; COSTA, Antonio Charlys da; TOZETTO-MENDOZA, Tania Regina; WITKIN, Steven S.; MENDES-CORREA, Maria Cassia
    Human enteroviruses (EV) are the most common cause of aseptic meningitis worldwide. Data on EV viral load in cerebrospinal fluid (CSF) and related epidemiological studies are scarce in Brazil. This study investigated the influence of EV viral load on CSF parameters, as well as identifying the involved species. CSF samples were collected in 2018-2019 from 140 individuals at The Hospital das Clinicas, Sao Paulo. The EV viral load was determined using real-time quantitative polymerase chain reaction, while EV species were identified by 5 ' UTR region sequencing. Median viral load was 5.72 log10 copies/mL and did not differ by subjects' age and EV species. Pleocytosis was observed in 94.3% of cases, with the highest white blood cell (WBC) counts in younger individuals. Viral load and WBC count were correlated in children (p = 0.0172). Elevated lactate levels were observed in 60% of cases and correlated with the viral load in preteen-teenagers (p = 0.0120) and adults (p = 0.0184). Most individuals had normal total protein levels (70.7%), with higher in preteen-teenagers and adults (p < 0.0001). By sequencing, 8.2% were identified as EV species A and 91.8% as species B. Age-specific variations in CSF characteristics suggest distinct inflammatory responses in each group.
  • conferenceObject
    SARS-CoV-2 Aerosol Generation During Respiratory Equipment Reprocessing
    (2021) CIOFI-SILVA, Caroline; BRUNA, Camila Quartim de Moraes; CIOFI-SILVA, Caroline L.; PAULA, Anderson Vicente de; BOAS, Lucy Santos Villas; FERREIRA, Noeli Evangelista; TOZETTO-MENDOZA, Tania; MENDES-CORREA, Maria Cassia; GRAZIANO, Kazuko Uchikawa
  • article 6 Citação(ões) na Scopus
    Are mobile phones part of the chain of transmission of SARS- CoV-2 in hospital settings?
    (2021) ESPINOZA, Evelyn Patricia Sanchez; CORTES, Marina Farrel; NOGUERA, Saidy Vasconez; PAULA, Anderson Vicente de; GUIMARAES, Thais; BOAS, Lucy Santos Villas; PARK, Marcelo; SILVA, Cristina Carvalho da; MORALES, Ingra; NETO, Lauro Vieira Perdigao; TOZETTO-MENDOZA, Tania Regina; BOSZCZOWSKI, Icaro; SABINO, Ester Cerdeira; MENDES-CORREA, Maria Cassia; LEVIN, Anna Sara; COSTA, Silvia Figueiredo
    Mobile phones (MPs) have become an important work tool around the world including in hospitals. We evaluated whether SARS-CoV-2 can remain on the surface of MPs of first-line healthcare workers (HCW) and also the knowledge of HCWs about SARS-CoV-2 cross-transmission and conceptions on the virus survival on the MPs of HCWs. A crosssectional study was conducted in the COVID-19 Intensive Care Unit of a teaching hospital. An educational campaign was carried out on cross-transmission of SARS-CoV-2, and its permanence in fomites, in addition to the proper use and disinfection of MPs. Herewith an electronic questionnaire was applied including queried conceptions about hand hygiene and care with MP before and after the pandemic. The MPs were swabbed with a nylon FLOQ SwabTM, in an attempt to increase the recovery of SARS-CoV-2. All MP swab samples were subjected to SARS-CoV-2 RT-PCR; RT-PCR positive samples were subjected to viral culture in Vero cells (ATCC (R) CCL-81TM). Fifty-one MPs were swabbed and a questionnaire on hand hygiene and the use and disinfection of MP was applied after an educational campaign. Most HCWs increased adherence to hand hygiene and MP disinfection during the pandemic. Fifty-one MP swabs were collected and two were positive by RT-PCR (4%), with Cycle threshold (Ct ) values of 34-36, however, the cultures of these samples were negative. Although most HCWs believed in the importance of cross-transmission and increased adherence to hand hygiene and disinfection of MP during the pandemic, SARS-CoV-2 RNA was detected in MPs. Our results suggest the need for a universal policy in infection control guidelines on how to care for electronic devices in hospital settings.
  • article 2 Citação(ões) na Scopus
    SARS-CoV-2 Detection and Culture in Different Biological Specimens from Immunocompetent and Immunosuppressed COVID-19 Patients Infected with Two Different Viral Strains
    (2023) MENDES-CORREA, Maria Cassia; SALOMAO, Matias Chiarastelli; GHILARDI, Fabio; TOZETTO-MENDOZA, Tania Regina; VILLAS-BOAS, Lucy Santos; PAULA, Anderson Vicente de; PAIAO, Heuder Gustavo Oliveira; COSTA, Antonio Charlys da; LEAL, Fabio E.; FERRAZ, Andrea de Barros Coscelli; SALES, Flavia C. S.; CLARO, Ingra M.; FERREIRA, Noely E.; PEREIRA, Geovana M.; JR, Almir Ribeiro da Silva; FREIRE, Wilton; ESPINOZA, Evelyn Patricia Sanchez; MANULI, Erika R.; ROMANO, Camila M.; JESUS, Jaqueline G. de; SABINO, Ester C.; WITKIN, Steven S.
    Introduction-The dynamics of SARS-CoV-2 shedding and replication in humans remain incompletely understood. Methods-We analyzed SARS-CoV-2 shedding from multiple sites in individuals with an acute COVID-19 infection by weekly sampling for five weeks in 98 immunocompetent and 25 immunosuppressed individuals. Samples and culture supernatants were tested via RT-PCR for SARS-CoV-2 to determine viral clearance rates and in vitro replication. Results-A total of 2447 clinical specimens were evaluated, including 557 nasopharyngeal swabs, 527 saliva samples, 464 urine specimens, 437 anal swabs and 462 blood samples. The SARS-CoV-2 genome sequences at each site were classified as belonging to the B.1.128 (ancestral strain) or Gamma lineage. SARS-CoV-2 detection was highest in nasopharyngeal swabs regardless of the virus strain involved or the immune status of infected individuals. The duration of viral shedding varied between clinical specimens and individual patients. Prolonged shedding of potentially infectious virus varied from 10 days up to 191 days, and primarily occurred in immunosuppressed individuals. Virus was isolated in culture from 18 nasal swab or saliva samples collected 10 or more days after onset of disease. Conclusions-Our findings indicate that persistent SARS-CoV-2 shedding may occur in both competent or immunosuppressed individuals, at multiple clinical sites and in a minority of subjects is capable of in vitro replication.
  • article 4 Citação(ões) na Scopus
    Characterization of Severe Acute Respiratory Syndrome Coronavirus 2 Omicron Variant Shedding and Predictors of Viral Culture Positivity on Vaccinated Healthcare Workers With Mild Coronavirus Disease 2019
    (2022) LUNA-MUSCHI, Alessandra; NOGUERA, Saidy Vasconez; BORGES, Igor C.; V, Anderson De Paula; CORTES, Marina Farrel; LAROCCA, Carolina; MARI, Julia Ferreira; GUIMARAES, Lara Silva Pereira; TORRES, Pablo Munoz; SCACCIA, Nazareno; VILLAS-BOAS, Lucy S.; JR, Almir Ribeiro da Silva; ANDRADE, Pamela S.; TEIXEIRA, Juliana C.; ESCADAFAL, Camille; OLIVEIRA, Vitor Falcao de; TOZETTO-MENDOZA, Tania R.; MENDES-CORREA, Maria Cassia; LEVIN, Anna S.; SABINO, Ester C.; COSTA, Silvia F.
    We evaluated the duration of viral culture positivity compared to rapid antigen test (RAT) and real-time reverse-transcription polymerase chain reaction (RT-PCR) in mild Omicron infection. Vaccinated persons are potentially transmissible up to day 7. RAT and RT-PCR are predictors of viral culture positivity. In this prospective cohort of 30 vaccinated healthcare workers with mild Omicron variant infection, we evaluated viral culture, rapid antigen test (RAT), and real-time reverse-transcription polymerase chain reaction (RT-PCR) of respiratory samples at days 5, 7, 10, and 14. Viral culture was positive in 46% (11/24) and 20% (6/30) of samples at days 5 and 7, respectively. RAT and RT-PCR (Ct <= 35) showed 100% negative predictive value (NPV), with positive predictive values (PPVs) of 32% and 17%, respectively, for predicting viral culture positivity. A lower RT-PCR threshold (Ct <= 24) improved culture prediction (PPV = 39%; NPV = 100%). Vaccinated persons with mild Omicron infection are potentially transmissible up to day 7. RAT and RT-PCR might be useful tools for shortening the isolation period.
  • article 1 Citação(ões) na Scopus
    Neutralizing antibodies against the SARS-CoV-2 Omicron variant following two CoronaVac vaccinations and a Pfizer/BioNTech mRNA vaccine booster
    (2022) SILVA JR., Almir Ribeiro da; VILLAS-BOAS, Lucy Santos; PAULA, Anderson Vicente de; TOZETTO-MENDOZA, Tania Regina; HONORATO, Layla; WITKIN, Steven S.; MENDES-CORREA, Maria Cassia
  • article 9 Citação(ões) na Scopus
    Generation of neutralizing antibodies against Omicron, Gamma and Delta SARS-CoV-2 variants following CoronaVac vaccination
    (2022) SILVA JR., Almir Ribeiro da; VILLAS-BOAS, Lucy Santos; TOZETTO-MENDOZA, Tania Regina; HONORATO, Layla; PAULA, Anderson de; WITKIN, Steven S.; MENDES-CORREA, Maria Cassia
    Vaccination is a fundamental tool to prevent SARS-CoV-2 infection and to limit the COVID-19 pandemic. The emergence of SARS-CoV-2 variants with multiple mutations has raised serious concerns about the ability of neutralizing antibody responses elicited by prior vaccination to effectively combat these variants. The neutralizing capacity against the Gamma, Delta and Omicron variants of sera from individuals immunized with the CoronaVac vaccine remains incompletely determined. The present study evaluated 41 health care workers at the Faculdade de Medicina of the Universidade de Sao Paulo, in Sao Paulo, Brazil, naive to previous SARS-CoV-2 infection, who were vaccinated with two doses of the CoronaVac SARS-CoV-2 vaccine 28 days apart. Neutralizing antibody levels against the Gamma, Delta, and Omicron variants were measured at 32 and 186 days after the second vaccination. We also measured neutralizing antibodies against Omicron in 34 of these individuals following a subsequent booster immunization with the Pfizer vaccine. Quantification of neutralizing antibodies was performed using the Cytopathic Effect-based Virus Neutralization test. Neutralization antibody activity against the Gamma, Delta and Omicron variants was observed in 78.0%, 65.9% and 58.5% of serum samples, respectively, obtained at a mean of 32 days after the second immunization. This decreased to 17.1%, 24.4% and 2.4% of sera having activity against Delta, Gamma and Omicron, respectively, at 186 days post-vaccination. The median neutralizing antibody titers at 32 days were 1:40, 1:20 and 1:20 against Gamma, Delta and Omicron, respectively, and decreased to an undetectable median level against all variants at the later time. A booster immunization with the Pfizer vaccine elicited neutralizing antibodies against Omicron in 85% of subjects tested 60 days after vaccination. We conclude that two doses of the CoronaVac vaccine results in limited protection of short duration against the Gamma, Delta and Omicron SARS-CoV-2 variants. A booster dose with the Pfizer vaccine induced antibody neutralizing activity against Omicron in most patients which was measurable 60 days after the booster.
  • article 2 Citação(ões) na Scopus
    Absence of neutralizing antibodies against the Omicron SARS-CoV-2 variant in convalescent sera from individuals infected with the ancestral SARS-CoV-2 virus or its Gamma variant
    (2022) VILLAS-BOAS, Lucy Santos; PAULA, Anderson Vicente de; SILVA, Almir Ribeiro da; PAIAO, Heuder Gustavo Oliveira; TOZETTO-MENDOZA, Tania Regina; MANULI, Erika Regina; LEAL, Fabio Eudes; FERRAZ, Andrea de Barros Coscelli; SABINO, Ester Cerdeira; BIERRENBACH, Ana Luiza; WITKIN, Steven Sol; MENDES-CORREA, Maria Cassia
    Objectives: The aim of the present study was to evaluate if neutralizing antibody responses induced by infection with the SARS-CoV-2 strain that was dominant at the beginning of the pandemic or by the Gamma variant was effective against the Omicron variant. Methods: Convalescent sera from 109 individuals, never exposed to a SARS-CoV-2 vaccine, who had mild or moderate symptoms not requiring hospitalization following either a documented SARS-CoV-2 ancestral strain infection or a Gamma variant infection, were assayed for in vitro neutralizing antibody activity against their original strains and the Omicron variant. Results: Following an infection with the ancestral strain, 56 (93.3%), 45 (77.6%) and 1 (1.7%) serum sample were positive for neutralizing antibodies against the ancestral, Gamma variant, and Omicron variant, respectively. After infection with the Gamma variant, 43 (87.8%) and 2 (4.1%) sera were positive for neutralizing antibodies against the Gamma and Omicron variants, respectively. Conclusions: Neutralizing antibodies generated following mild or moderate infection with the SARS-CoV-2 ancestral strain or the Gamma variant are not protective against the Omicron variant.
  • article 7 Citação(ões) na Scopus
    SARS-CoV-2 in a stream running through an underprivileged, underserved, urban settlement in Sao Paulo, Brazil: A 7-month follow-up
    (2021) RAZZOLINI, Maria Tereza Pepe; BARBOSA, Mikaela Renata Funada; ARAUJO, Ronalda Silva de; OLIVEIRA, Ivo Freitas de; MENDES-CORREA, Maria Cassia; SABINO, Ester C.; GARCIA, Suzi Cristina; V, Anderson de Paula; VILLAS-BOAS, Lucy S.; COSTA, Silvia Figueiredo; DROPA, Milena; ASSIS, Denise Brandao de; LEVIN, Beatriz S.; LIMA, Antonio Carlos Pedroso de; LEVIN, Anna S.
    COVID-19 pandemic has led to concerns on the circulation of SARS-CoV-2 in the environment, its infectivity from the environment and, the relevance of transmission via environmental compartments. During 31 weeks, water samples were collected from a heavily contaminated stream going through an urban, underprivileged community without sewage collection. Our results showed a statistically significant correlation between cases of COVID-19 and SARS in the community, and SARS-CoV-2 concentrations in the water. Based on the model, if the concentrations of SARS-CoV-RNA (N1 and N2 target regions) increase 10 times, there is an expected increase of 104% [95%CI: (62-157%)] and 92% [95%CI: (51-143%)], respectively, in the number of cases of COVID-19 and SARS. We believe that differences in concentration of the virus in the environment reflect the epidemiological status in the community, which may be important information for surveillance and controlling dissemination in areas with vulnerable populations and poor sanitation. None of the samples were found infectious based cultures. Our results may be applicable globally as similar communities exist worldwide.