EVERSON LUIZ DE ALMEIDA ARTIFON

(Fonte: Lattes)
Índice h a partir de 2011
21
Projetos de Pesquisa
Unidades Organizacionais
LIM/26 - Laboratório de Pesquisa em Cirurgia Experimental, Hospital das Clínicas, Faculdade de Medicina - Líder

Resultados de Busca

Agora exibindo 1 - 5 de 5
  • conferenceObject
    EUS-FNA OF PANCREATIC SOLID MASSES: A PROSPECTIVE RANDOMIZED TRIAL COMPARING SUCTION WITH SLOW PULL
    (2018) CHENG, Spencer; DANIELLE, Chacon A.; ARTIFON, Everson L.; MATUGUMA, Sergio E.; SANTOS, Marcos E. dos; SAKAI, Christiano M.; CHAVES, Dalton; MOURA, Diogo T. De; MOURA, Eduardo T.
  • article 11 Citação(ões) na Scopus
    Suction versus slow-pull for endoscopic ultrasound-guided fine-needle aspiration of pancreatic tumors: a prospective randomized trial
    (2020) CHENG, Spencer; BRUNALDI, Vitor O.; MINATA, Mauricio K.; CHACON, Danielle A.; SILVEIRA, Eduardo B.; MOURA, Diogo T. H. de; SANTOS, Marcos E. L. Dos; MATUGUMA, Sergio E.; CHAVES, Dalton M.; FRANCA, Raony F.; JACOMO, Alfredo L.; ARTIFON, Everson L. A.
    Background: Suction (S) is commonly used to improve cell acquisition during endoscopic ultrasoundguided fine-needle aspiration (EUS-FNA). Slow-pull (SP) sampling is another technique that might procure good quality specimens with less bloodiness. We aimed to determine if SP improves the diagnostic yield of EUS-FNA of pancreatic masses. Methods: Patients with pancreatic solid masses were randomized to four needle passes with both techniques in an alternate fashion. Sensitivity, specificity, positive, and negative predictive values were calculated. Cellularity and bloodiness of cytological samples were assessed and compared according to the technique. Results: Sensitivity, specificity, and accuracy of suction vs. SP were 95.2% vs. 92.3%; 100% vs. 100; 95.7% vs. 93%, respectively. As to the association of methods, they were 95.6, 100 and 96%, respectively. Positive predictive values for S and SP were 100%. There was no difference in diagnostic yield between S and SP (p = 0.344). Cellularity of samples obtained with SP and Suction were equivalent in both smear evaluation (p = 0.119) and cell-block (0.980). Bloodiness of SP and suction techniques were similar as well. Conclusions: S and SP techniques provide equivalent sensitivity, specificity, and accuracy. Association of methods seems to improve diagnostic yield. Suction does not increase the bloodiness of samples compared to slow-pull.
  • article 6 Citação(ões) na Scopus
    Natural orifice transluminal endoscopic surgery to salvage a migrated stent during EUS-guided hepaticogastrostomy
    (2016) MOURA, Diogo Turiani Hourneaux De; MESTIERI, Luiz Henrique M.; CHENG, Spencer; RODELA, Gustavo Luis; MOURA, Eduardo Guimaraes Hourneaux De; SAKAI, Paulo; OLIVEIRA, Joel F.; ARTIFON, Everson L.
  • article
    EUS-FNA versus ERCP for tissue diagnosis of suspect malignant biliary strictures: a prospective comparative study
    (2018) MOURA, Diogo Turiani Hourneaux; GUIDAMARAES, Eduardo; MOURA, Hourneaux de; MATUGUMA, Sergio Eiji; SANTOS, Marcos Eduardo dos; MOURA, Eduardo Turiani Hourneaux; BARACAT, Felipe Iankelevich; ARTIFON, Everson L. A.; CHENG, Spencer; BERNARDO, Wanderley Marque; CHACON, Danielle; TANIGAWA, Ryan; JUKEMURA, Jose
    Background and study aims Biliary strictures are frequently a challenging clinical scenario and the anatomopathological diagnosis is essential in the therapeutic management, whether for curative or palliative purposes. The acquisition of specimens is necessary since many benign diseases mimic biliopancreatic neoplasms. Endscopic retrograde cholangiopancreatography (ERCP) is the traditionally used method despite the low sensitivity of biliary brush cytology and forceps biopsy. On the other hand, several studies reported good accuracy rates using endoscopic ultrasound- guided fine-needle aspiration (EUS-FNA). The aim of this prospective study was to compare, the accuracy of EUS-FNA and ERCP for tissue sampling of biliary strictures. Patients and methods After performing the sample size calculation, 50 consecutive patients with indeterminate biliary strictures were included to undergo ERCP and EUS on the same sedation. The gold-standard was surgery or 6 months' follow-up. Evaluation of the diagnostic indices (sensitivity, specificity, positive and negative predictive value, positive and negative likelihood ratio), concordance and adverse events among the methods were performed. Also, subtype analyses of the techniques, anatomical localization and size of the lesion were included. Results The final diagnoses reported in 50 patients were 47 malignant, 1 suspicious and 2 benign lesions. 31 lesions were extraductal and 19 intraductal, 35 were distal and 15 proximal strictures. In the intention-to-treat analysis, the sensitivity and accuracy of EUS-FNA were superior than ERCP tissue sampling (93,8%, 94% vs. 60,4%, 62%, respectively) (P = 0.034), with similar adverse events. There was no concordance between the methods and combining both methods improved the sensitivity and accuracy for 97.9% and 98%, respectively. In the subtype analyses, the EUS-FNA was superior, with a higher accuracy than ERCP tissue sampling in evaluating extraductal lesions (100% vs. 54.8 %, P = 0.019) and in those larger than 1.5 cm (95.8% vs. 61.9%, P = 0.031), but were similar in evaluating intraductal lesions and lesions smaller than 1.5 cm. There was no significant difference between the methods in the analyzes of proximal, distal and pancreatic lesions. Conclusion EUS-FNA is better than ERCP with brush cytology and intraductal forceps biopsy in diagnosing malignant biliary strictures, mainly in the assessment of extraductal lesions and in those larger than 1.5 cm. Combining ERCP with tissue sampling and EUS-FNA is feasible, the techniques have similar complication rates, and the combination greatly improves diagnostic accuracy.
  • article 5 Citação(ões) na Scopus
    Guide wire-assisted cannulation versus conventional contrast to prevent pancreatitis: A systematic review and meta-analysis based on randomized control trials
    (2016) DE MOURA, Eduardo T.H.; DE MOURA, Eduardo G.H.; BERNARDO, Wanderley; CHENG, Spencer; KONDO, Andre; DE MOURA, Diogo T.H.; BRAVO, Jose; ARTIFON, Everson L.A.
    Objective: Through this systematic review and meta-analysis, we aim to clarify the differences between these two techniques, thus improving primary success cannulation and reducing complications during endoscopic retrograde cholangiopancreatography, primarily pancreatitis. Methods: A comprehensive search was conducted to search for data available up until June2015from the most important databases available in the health field: EMBASE, MEDLINE (via PubMed), Cochrane, LILACS and CENTRAL (via BVS), SCOPUS, the CAPES database (Brazil), and gray literature. Results: Nine randomized clinical trialsincluding2583 people were selected from20,198 studies for meta-analysis. Choledocholithiasis had been diagnosed in mostly (63.8%) of the patients, who were aged an average of 63.15 years. In those patients treated using the guide wire-assisted cannulation technique, provided a significantly lower instance of pancreatitis (RD=0.03; 95% CI: 0.01-0.05; I2= 45%) and greater primary success cannulation (RD=0.07; 95% CI: 0.03-0.12; I2=12%) than conventional contrast cannulation. Conclusions: The guide wire-assisted technique, when compared to the conventional contrast technique, reduces the risk of pancreatitis and increases primary success cannulation rate. Thus, guide wire-assisted cannulation appears to be the most appropriate first-line cannulation technique