MAURICIO IBRAHIM SCANAVACCA

(Fonte: Lattes)
Índice h a partir de 2011
24
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina
LIM/65, Hospital das Clínicas, Faculdade de Medicina - Líder

Resultados de Busca

Agora exibindo 1 - 10 de 12
  • conferenceObject
    Mechanical Esophageal Displacement for Esophageal Safety of Mechanical Esophageal Displacement for Esophageal Thermal Injury Prevention During Atrial Fibrillation Ablation in Swine
    (2019) PEREIRA, Renner; PISANI, Cristiano F.; AIELLO, Vera; CESTARI, Idagene A.; MOURA, Daniel; CHOKR, Muhieddine; HARDY, Carina; SISSY, Melo; SCANAVACCA, Mauricio; HACHUL, Denise
  • article 6 Citação(ões) na Scopus
  • article 6 Citação(ões) na Scopus
    Routine Coagulation Tests in Patients With Nonvalvular Atrial Fibrillation Under Dabigatran and Rivaroxaban Therapy: An Affordable and Reliable Strategy?
    (2019) SILVA, Vanessa M.; SCANAVACCA, Mauricio; DARRIEUX, Francisco; CAVALHEIRO, Cyrillo; STRUNZ, Celia C.
    Dabigatran and rivaroxaban, direct oral anticoagulants (DOACs), affect coagulation tests, and knowledge of their effects is important for therapeutic monitoring. Our aim was to examine the association between DOAC levels and routine coagulation tests in patients with nonvalvular atrial fibrillation. Samples from patients receiving dabigatran (150 mg) and patients receiving rivaroxaban (20 mg) were collected 2 hours after drug intake. Direct oral anticoagulant concentrations were determined using direct Hemoclot thrombin inhibitor (HTI) assay (HTI test) and a direct Xa inhibitor (Anti Xa-Riva). The routine coagulation measured included activated partial thromboplastin time (aPTT) and prothrombin time (PT). The median plasmatic dabigatran was 128.3 ng/mL (95% confidence interval [CI]: 93.7-222.6 ng/mL). The HTI exhibited a good correlation with aPTT (R-2 = 0.74; P < .0001). The median plasmatic rivaroxaban was 223.9 ng/mL (95% CI: 212.3-238.9 ng/mL). Anti-Xa-Riva correlated with PT (R-2 = 0.69, P< .0001) and aPTT (R-2 = 0.36, P < .001), but prolonged PT results were obtained, even below the rivaroxaban therapeutic range (20%). The routine coagulation tests were able to identify out of therapeutic range concentrations for dabigatran and rivaroxaban. We suggest the use of these screening tests to better understand and monitor the subtherapeutic concentrations of these DOACs.
  • article 5 Citação(ões) na Scopus
    Is It Safe for Patients With Cardiac Channelopathies to Undergo Routine Dental Care? Experience From a Single-Center Study
    (2019) OLIVEIRA, Ana Carolina Guimaraes; NEVES, Itamara Lucia Itagiba; SACILOTTO, Luciana; OLIVETTI, Natalia Quintella Sangiorgi; SANTOS-PAUL, Marcela Alves dos; MONTANO, Tania Cristina Pedroso; CARVALHO, Cintia Maria Alencar; WU, Tan Chen; GRUPI, Cesar Jose; BARBOSA, Silvio Alves; PASTORE, Carlos Alberto; SAMESIMA, Nelson; HACHUL, Denise Tessariol; SCANAVACCA, Mauricio Ibrahim; NEVES, Ricardo Simoes; DARRIEUX, Francisco Carlos Costa
    Background-Brugada syndrome and long-QT syndrome may account for at least one third of unexplained sudden cardiac deaths. Dental care in patients with cardiac channelopathies is challenging because of the potential risk of life-threatening events. We hypothesized that the use of local dental anesthesia with lidocaine with and without epinephrine is safe and does not result in life-threatening arrhythmias in patients with channelopathies. Methods and Results-We performed a randomized, double-blind pilot trial comparing the use of 2% lidocaine without a vasoconstrictor and with 1:100 000 epinephrine in 2 sessions of restorative dental treatment with a washout period of 7 days (crossover trial). Twenty-eight-hour Holter monitoring was performed, and 12-lead electrocardiography, digital sphygmomanometry, and anxiety scale assessments were also conducted at 3 time points. Fifty-six dental procedures were performed in 28 patients (18 women, 10 men) with cardiac channelopathies: 16 (57.1%) had long-QT syndrome, and 12 (42.9%) had Brugada syndrome; 11 (39.3%) of patients had an implantable defibrillator. The mean age was 45.9 +/- 15.9 years. The maximum heart rate increased after the use of epinephrine during the anesthesia period from 82.1 to 85.8 beats per minute (P=0.008). In patients with long-QT syndrome, the median corrected QT was higher, from 450.1 to 465.4 ms (P 0.009) at the end of anesthesia in patients in whom epinephrine was used. The other measurements showed no statistically significant differences. No life-threatening arrhythmias occurred during dental treatment. Conclusions-The use of local dental anesthesia with lidocaine, regardless of the use of a vasoconstrictor, did not result in life-threatening arrhythmias and appears to be safe in stable patients with cardiac channelopathies.
  • article 0 Citação(ões) na Scopus
    The Neurolinguistics of the Heart
    (2019) RIVAROLA, Esteban Wisnivesky; SCANAVACCA, Mauricio
  • article 2 Citação(ões) na Scopus
    Approaches to the Diagnosis and Management of Atrial-Esophageal Fistula After Catheter Ablation for Atrial Arrhythmias
    (2019) WU, Tan Chen; PISANI, Cristiano; SCANAVACCA, Mauricio I.
    Purpose of ReviewCatheter ablation has become a cornerstone of therapy in the management of patients with atrial fibrillation (AF). Thermal energy generated in the left atrium (LA) during ablation has the potential to damage adjacent structures. The most feared and rare complication in these ablations is atrial-esophageal fistula (AEF) result from the thermal injury to the esophagus due to the proximity to the LA, with potential catastrophic outcome. This review focuses on the diagnosis and management of AEF after catheter ablation for AF, including preventive measures to avoid esophageal lesions.Recent FindingsSymptoms of AEF are often vague and nonspecific, sometimes asymptomatic until they present with fistula or perforation, making the diagnosis somewhat challenging. The esophagogastroduodenoscopy is the gold standard for early detection of esophageal lesions related to AF ablation. Chest CT with oral and intravenous contrast is preferred when there is suspicion of perforation. The use of an esophageal temperature probe during ablation to monitoring esophageal temperature, associated with mechanical displacement of the esophagus, may be feasible to prevent thermal esophageal lesions and enabling adequate energy delivery to the posterior wall of the LA. Prophylactic use of proton pump inhibitors after AF ablation is accepted to be effective and justified as preventive treatment.SummaryAEF is an unpredictable complication. Be aware of these complications in the follow-up of patients after AF ablation can lead to the early recognition to start treatment, including surgical repair, as soon as possible to prevent the fatal outcome.
  • article 0 Citação(ões) na Scopus
  • article 1 Citação(ões) na Scopus
    Programmed Ventricular Stimulation in the Management of Brugada Syndrome Patients
    (2019) SCANAVACCA, Mauricio Ibrahim; HACHUL, Denise Tessariol
  • article 1 Citação(ões) na Scopus
  • article 1 Citação(ões) na Scopus
    Epicardial ablation of ventricular tachycardia using a new high-density mapping system
    (2019) CAVACO, Diogo; CARMO, Pedro; MESQUITA, Joao; SCANAVACCA, Mauricio; ADRAGAO, Pedro
    We report the case of a 44-year-old woman who was referred for ablation of recurrent ventricular tachycardia (VT) in the setting of dilated cardiomyopathy secondary to myocarditis. The ECG displayed a right bundle branch block morphology and superior axis in the frontal plane, associated with a pseudo delta wave in the precordial leads that suggested an epicardiat origin. Cardiac magnetic resonance performed prior to the procedure showed late gadolinium enhancement at the lateral watt of the left ventricle (LV) and excluded subendocardial fibrosis in either ventricle. This information was crucial and influenced the ablation strategy, identifying the target area as exclusively epicardiat, thus avoiding unnecessary mapping of the endocardial surface of the LV. Epicardiat activation mapping and ablation during VT were performed using the Orion (R) highdensity catheter (Boston Scientific Inc.) and the Rhythmid (R) mapping system (Boston Scientific Inc.). Applications near the exit site immediately terminated the tachycardia, which was no longer inducible. One year after the procedure the patient was still in sinus rhythm with no episodes of VT or non-sustained VT recorded by continuous monitoring via an implanted cardioverter-defibrillator. (C) 2019 Sociedade Portuguesa de Cardiologia.