EDNA FRASSON DE SOUZA MONTERO

(Fonte: Lattes)
Índice h a partir de 2011
15
Projetos de Pesquisa
Unidades Organizacionais
Departamento de Cirurgia, Faculdade de Medicina - Docente
LIM/08 - Laboratório de Anestesiologia, Hospital das Clínicas, Faculdade de Medicina - Líder

Resultados de Busca

Agora exibindo 1 - 5 de 5
  • article 12 Citação(ões) na Scopus
    Polypropylene and polypropylene/polyglecaprone (Ultrapro(r)) meshes in the repair of incisional hernia in rats
    (2015) UTIYAMA, Edivaldo Massazo; ROSA, Maria Beatriz Sartor de Faria; ANDRES, Marina de Paula; MIRANDA, Jocielle Santos de; DAMOUS, Sérgio Henrique Bastos; BIROLINI, Cláudio Augusto Vianna; DAMOUS, Luciana Lamarão; MONTERO, Edna Frasson de Souza
    PURPOSE: To compare the inflammatory response of three different meshes on abdominal hernia repair in an experimental model of incisional hernia. METHODS: Median fascial incision and skin synthesis was performed on 30 Wistar rats. After 21 days, abdominal hernia developed was corrected as follows: 1) No mesh; 2) Polypropylene mesh; and, 3) Ultrapro(r) mesh. After 21 days, the mesh and surrounding tissue were submitted to macroscopic (presence of adhesions, mesh retraction), microscopic analysis to identify and quantify the inflammatory and fibrotic response using a score based on a predefined scale of 0-3 degrees, evaluating infiltration of macrophages, giant cells, neutrophils and lymphocytes. RESULTS: No significant difference was seen among groups in adherences, fibrosis, giant cells, macrophages, neutrophils or lymphocytes (p>0.05). Mesh shrinkage was observed in all groups, but also no difference was observed between polypropylene and Ultrapro mesh (7.0±9.9 vs. 7.4±10.1, respectively, p=0.967). Post-operatory complications included fistula, abscess, dehiscence, serohematic collection and reherniation, but with no difference among groups (p=0.363). CONCLUSION: There is no difference between polypropylene (high-density) and Ultrapro(r) (low-density) meshes at 21 days after surgery in extraperitoneal use in rats, comparing inflammatory response, mesh shortening, adhesions or complications.
  • conferenceObject
    Effects of polypropylene mesh in testis and duct deferens in rats: a comparative study of two approaches
    (2015) UTIYAMA, Edivaldo M.; DAMOUS, Sergio H.; MIRANDA, Jocielle S.; SANDERS, Felipe Hada; PARDO, Maisa H.; PARDO, Maisa; MONTERO, Edna F. S.; DAMOUS, Luciana L.; DAMOUS, Luciana; BIROLINI, Claudio
  • article 1 Citação(ões) na Scopus
    Could polypropylene mesh impair male reproductive organs? Experimental study with different methods of implantation
    (2020) DAMOUS, S. H. B.; DAMOUS, L. L.; MIRANDA, J. S.; MONTERO, E. F. S.; BIROLINI, C.; UTIYAMA, E. M.
    Purpose To evaluate the vas deferens and testicles of rats submitted to bilateral inguinotomy and polypropylene (PP) mesh placement. Method Sixty Wistar rats were randomized into three groups: Control (inguinotomy only), mesh placement over the vas deferens (Mesh-DD) or under the spermatic funiculus (Mesh-SF). The following analyses were performed: vas deferens morphometry (lumen area and wall thickness), quantification of collagen fibers, spermatogenesis, apoptosis (cleaved caspase-3 and TUNEL) and cellular proliferation (Ki67). Quantitative gene expression (qPCR) for apoptosis and inflammatory cytokines were evaluated by RT-PCR. Results In the apoptosis pathway, Mesh-DD showed one upregulated gene (Il10) and three downregulated genes (Fadd, Tnfrsf1b and Xiap). In Mesh-SF, 17 genes were downregulated. In the inflammation pathway (Mesh-DD), one gene was upregulated (Il1r1), and one gene was downregulated (Ccl12). In Mesh-SF, three genes were upregulated (Il1r1, Tnfsf13b and Csf1), and two were downregulated (Ccl12 and Csf2). PP mesh placement preserved spermatogenesis and did not alter the vas deferens or the testicle. In the ductus deferens, there was reduced luminal area (30 days), increased wall thickness (90 days), and increased type III collagen and cell proliferation (30 and 90 days) (p < 0.05). In the testicle, cell proliferation was greater in the Mesh-DD (p < 0.05). Conclusions PP mesh, whether or not in direct contact with spermatic funicular structures, induces changes that were not sufficient to cause damage to the evaluated organs.
  • article 5 Citação(ões) na Scopus
    Temporary abdominal closure with zipper-mesh device for management of intra-abdominal sepsis
    (2015) UTIYAMA, Edivaldo Massazo; PFLUG, Adriano Ribeiro Meyer; DAMOUS, Sérgio Henrique Bastos; RODRIGUES-JR, Adilson Costa; MONTERO, Edna Frasson de Souza; BIROLINI, Claudio Augusto Vianna
    OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years); 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.
  • conferenceObject
    Analysis of Duct Deferens and Testis of Rats Submitted to Bilateral Inguinal Hernioplasty
    (2017) DAMOUS, Sergio H.; BIROLINI, Claudio A. V.; MIRANDA, Jocielle S.; MONTERO, Edna F. S.; DAMOUS, Luciana L.; UTIYAMA, Edivaldo M.