VINCENZO PUGLIESE

(Fonte: Lattes)
Índice h a partir de 2011
8
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina - Médico

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • article 11 Citação(ões) na Scopus
    Acoustic radiation force impulse (ARFI) elastography compared with biopsy for evaluating hepatic fibrosis after liver transplantation: a cross-sectional diagnostic study
    (2016) SCHMILLEVITCH, Joel; CHAMMAS, Maria Cristina; PUGLIESE, Vincenzo; ABDALA, Edson; RIZZON, Adriana Cortez; ALVES, Venancio; CARNEIRO, Luiz Augusto; CERRI, Giovanni
    CONTEXT AND OBJECTIVE: Biopsies are used after liver transplantation to evaluate fibrosis. This study aimed to evaluate the elasticity of transplanted livers by means of a non-invasive examination, acoustic radiation force imaging (ARFI) elastography, correlating the results with the histological analysis. DESIGN AND SETTING: Cross-sectional study in a public university hospital. METHODS: All patients consecutively operated between 2002 and 2010 with an indication for biopsy were evaluated by means of elastography. The radiologist evaluating ARFI and the pathologist doing anatomopathological examinations were blinded to each other's evaluations. RESULTS: During the study period, 33 patients were included. The indication for transplantation was cirrhosis due to hepatitis C in 21 cases (63%). Liver biopsies showed absence of fibrosis (F0) in 10 patients, F1 in 11, F2 in 8 and F3 in 4. There were no cases of F4 (cirrhosis). The difference in ARFI values (degree of fibrosis) was 0.26 (95% confidence interval, CI: 0.07-0.52) between the groups F0-F1 and F2-F4 (P = 0.04). An area under the curve of 0.74 (CI: 0.55-0.94) and a cutoff of 1.29 m/s between the groups resulted in the best relationship between sensitivity and specificity. Sensitivity (0.66; CI: 0.50-0.83) was lower than specificity (0.85; CI: 0.72-0.97). There was no significant difference in ARFI between patients with hepatitis C and those with other diseases. CONCLUSIONS: The values obtained from elastography were not affected by inflammatory reaction or anatomical alterations. A cutoff point of 1.29 m/s separating patients with or without significant fibrosis was identified.
  • article 12 Citação(ões) na Scopus
    Trombose de veia porta no transplante hepático
    (2012) PÉCORA, Rafael Antonio Arruda; CANEDO, Bernardo Fernandes; ANDRAUS, Wellington; MARTINO, Rodrigo Bronze de; SANTOS, Vinicius Rocha; ARANTES, Rubens Macedo; PUGLIESE, Vincenzo; D´ALBUQUERQUE, Luiz Augusto Carneiro
    BACKGROUND: Portal vein thrombosis was considered a contraindication for liver transplantation in the past because of the high morbidity and mortality rates. Many advances made the results better. AIM: Review the advances and surgical strategies for liver transplantation in presence of portal vein thrombosis. METHOD: Survey of publications in Medline, Scielo and Lilacs databases. Headings crossed: portal vein thrombosis, liver transplantation, vascular complications, jump graft, graft failure, multivisceral transplant. Data analyzed were epidemiology, risk factors, classification, diagnosis, surgical strategies and outcomes. CONCLUSION: Portal vein thrombosis is not a contraindication for liver transplantation anymore. There are many strategies to perform the liver transplantation in this condition, depending on portal vein thrombosis grade. Regardless higher morbidity and re-trhombosis rates, the outcomes of liver transplantation in portal vein thrombosis are similar to series without portal vein thrombosis.