JOYCE MATIE KINOSHITA DA SILVA ETTO

Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/07 - Laboratório de Gastroenterologia Clínica e Experimental, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • article 5 Citação(ões) na Scopus
    DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION
    (2020) MATTAR, Rejane; MARQUES, Sergio Barbosa; MINATA, Maurício Kazuyoshi; SILVA-ETTO, Joyce Matie Kinoshita da; SAKAI, Paulo; DE MOURA, Eduardo Guimarães Hourneaux
    ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.
  • article 10 Citação(ões) na Scopus
    Evaluation of diagnostic accuracy of two rapid stool antigen tests using an immunochromatographic assay to detect Helicobacter pylori
    (2017) SILVA-ETTO, Joyce Matie Kinoshita da; MATTAR, Rejane; VILLARES-LOPES, Cibele Aparecida; MARQUES, Sergio Barbosa; CARRILHO, Flair Jose
    Objectives: The stool antigen assay for H. pylori infection diagnosis with monoclonal antibodies is a simple and recommended technique by the Maastricht V/Florence consensus report. Recently, Pylori K-Set K-1219 (Coris Bioconcept Sprl, Belgium) and HP-F23 (Symbiosys, Brazil) have been made commercially available in Brazil. Thus, the aim of this study was to evaluate the diagnostic accuracies of these two rapid stool antigen tests by immunochromatographic assays (index tests) for the clinical practice. Design and methods: A total of 98 patients who underwent upper gastrointestinal endoscopy and 13C-urea breath test entered the study. H. pylori infection status was defined by the combination of the rapid urease test and the C-13-urea breath test (reference standard). Two observers who were aware of H. pylori status performed the reading of index tests. Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value with 95% confidence intervals, positive likelihood ratio, negative likelihood ratio and kappa index measure of agreement) were determined. Results: The index tests where in perfect agreement with the H. pylori status with kappa values of 0.87 for Pylori K-Set K-1219 and 0.92 for HP-F23. The sensitivity of HP-F23 was 97.9% (IC95%: 87.5-100) and specificity was 93.8% (IC95%; 84-97.2). The positive likelihood ratio was 15.8, and the negative likelihood ratio was 0.02. The Pylori K-Set K-1219 had a sensitivity of 87.7% (IC95%: 74.5-94.9) and a specificity of 100% (IC95%: 91.6-100); the positive likelihood ratio was infinity, and the negative likelihood ratio was 0.1. The test line on the cassette device of HP-F23 was stronger than of the Pylori K-Set K-1219. Conclusion: The HP-F23 test performed better in clinical practice. Nonetheless, the C-13-urea breath test is more reliable technique. Moreover, caution must be paid to the trace or clear pale test line readings that were observed in false positive and false negative results, leading to incorrect management of the patient.